Laserfiche WebLink
FIRE ALARM CONTROL PANEL NAC #1 POWER SUPPLY NAC #2 POWER SUPPLY <br /> ( ELECTRICAL ROOM 165 ) ( ELECTRICAL ROOM 165 ) ( ELECTRICAL ROOM 165 ) <br /> z � <br /> vv <br /> Nx <br /> ©POTTrT Project Name: EHA-sILVERVIEw _ standby Hours: zap FIREALARM BOOSTER POWER SUPPLY BATTERY CALCULATION FIREALARM BOOSTER POWER SUPPLYBATTERY CALCULATION Ld <br /> �Y � a <br /> The symboll9l••-o111,Pro`1`ecuon EVERETT,WASHINGTON Alarm Mins:L5 Project:EHA-SILVER VIEW Project:EHA-SILVER VIEW <br /> AFC-100 Installed By: GUARDIAN SECURITY SYSTEMS Efficiency Factor.Iz0% Panel: NAC#1 POTTER PSN-106 POWER SUPPLY Panel: NAC#2 POTTER PSN-106 POWER SUPPLY I- <br /> Battery&Voltage Drop Designed By: L.ALLEN SLCType:Ciass B Date: November 22,2024 Date: November 22,2024 w <br /> Calculations Date: 11/22/2024 NAC Source Voltage: 20.4 Module/Device Qty Standby Total Standby Alarm Total Alarm Module/Device Qty Standby Total Standby Alarm Total Alarm Q s <br /> Model B:AFC-100 Max Panel Current(amps):5 mA mA mA (mA) (mA) (mA) (mA) (mA) Q <br /> Power Module 1 75 75 75 75 Power Module 1 75 75 75 75 N <br /> Panel ID: FACP User assumes all responsibility to ensure the quantities and current �O <br /> Location: ELECTRICAL ROOM 165 draw values in this worisheet are accurate prior to submittal. 0 0 0 0 cc Q <br /> A TOTAL FIRE ALARM POWER SUPPLY 75 75 A TOTAL FIRE ALARM POWER SUPPLY 75 75 oN <br /> 1 AFC-100 Analog Addressable FACP 0.130 0.130 0.220 0.220 J <br /> B Auxiliary Device Current 0 0 B Auxiliary Device Current 0 0 'UPanel Standby: 0.130 Panel Alarm: 0.220 CID - H <br /> C Notification Appliance Load(Max.Total/n-A) 0 4688 C Notification Appliance Load(Max.Total/TtA) 0 3457 <br /> 1 U D-2000/U D-1000 DACT Ca rd 0.016 0.016 0.023 0.023 <br /> 1 RA-6500(R/F) Flush Mount LOD Annunciator 0.020 0.020 0.050 0.050 <br /> 1 PAD100-510E-127 SLC Expa nder 0.060 0.060 0.060 0.060 m <br /> "REQUIRED IF USING NOHMI PROTOCOL SLC DEVCES TOtal(A)= 75 Total(B)= 4763 Total(A)= 75 Total(B)= 3532 <br /> (Maximum cumentdrewon P-Link limited to lAmp) BUNK Standby: 0.096 BUNK Alarm: 0.133 w <br /> *Only enter quantity if PLINK power is being used to power devices w <br /> CALCULATION CALCULATION <br /> AFC/ARC/IPA Series-PAD100/200 <br /> D Total current ratings of all devices in system(line A+line B+line C) 75 4763 D Total current ratings of all devices in system(line A+line B+line C) 75 3532 <br /> 8 PAD-PD Analog Photo Smoke 0.000300 0.002400 0-000300 0.002400 E Total current ratings converted to amperes(line D x.001) 0.075 4.763 E Total current ratings convened to amperes line D x.001 0.075 3.532 <br /> 84 PAD-HD Analog Fixed Temp Heat 0.000300 0.025200 0-000300 0.025200 <br /> 1 PADIDD-PSSA/PSDA Addressable Pull Station Single/Dual Action 0.000200 0.000200 0.000200 0.000200 F Number of standby hours(24 or 60 per NFPA 72,Chapter 1,15.2.5). 24 F Number of standby hours(24 or 60 per NFPA 72,Chapter 1,1-5.2.5). 24 Zo <br /> 1 PAD10D-SIM Single Input Module 0.000240 0.000240 0.000240 0.000240 PY y PY y z <br /> G Multiply lines E and F Total Standby AH 1.8 G Multiply lines E and F Total Standby AH 1.8 �' o <br /> 2 PAD1DO-DIM Dual Input Module 0.000240 0.000480 0.000240 0.000480 H Alarm sounding period in hours(5 Mins= 0.833 Hours) 0.0833 H Alarm sounding period in hours(5 Mins= 0.833 Hours) 0.0833 <br /> 4 PADI00.RM Rela Module 0.000240 0.000960 0.000240 0.000960 w u <br /> I Multiply lines E and H Total Alarm AH 0.3967579 I Multiply lines E and H Total Alarm AH 0.2942156 N <br /> a w <br /> J Add lines G and I Total Standby and Alarm AH 2.1967579 J Add lines G and I Total Standby and Alarm AH1 2.0942156 <br /> 1 Notification NAC FP-1 0.00000 1.14170 K IMultiply line J by 1.2(20%extra insurance to meet desired performance) 2.636109481 K IMultiply line J by 1.2(20%extra insurance to meet desired performance) 1 2.51305872 w <br /> 2 0.00000 0.00000 3 <br /> NAC standby: 0.00000 NACAIarm: 2.14170 12-V DC BATTERY SIZE RECOMMENDED(AMPERE-HOUR) 8 12-V DC BATTERY SIZE RECOMMENDED(AMPERE-HOUR) 8 <br /> 0 <br /> ***RECOMMENDED MINIMUM BATTERY SIZE= 12VDC 8.0 AMP-HOUR*** ***RECOMMENDED MINIMUM BATTERY SIZE=12VDC 7.0 AMP-HOUR*** o <br /> 1 0.00000 0.00000 <br /> 2 0.00000 0.00000 N <br /> 1/0 Standby: 0.00000 1/0 Alarm: 0.00000 o\ <br /> Notification Appliance Circuit Detail Notification Appliance Circuit Detail <br /> Panel Current: 0.13000 0.22000 PROJECT: EHA-SILVER VIEW PROJECT: EHA-SILVERVIEW <br /> P-LinkCurrent: 0.09600 0.13300 Panel: NAC#1 PSN-106POWER SUPPLY WreResistance 2.58 Panel: NAC#2 PSN-106POWER SUPPLY Wire Resistance 2.58 o aaaa <br /> SLC Device Current: 0.02948 0.06548 Data: November22,2024 CURRENT TOTAL=4688.00 Date: November 22,2024 CURRENTTOTAL=3457.80 z <br /> NAC Circuit Current: 0.00000 1.14170 CIRCUIT: NAC N11-1 Ala ma Alarm Wire Wire Voltage chirc-u-N CIRCUIT: NAC N2-l'OEMMMMMMINW Alarm <br /> 1/0 Circuit Current: 0.00000 0.00000 QTY <br /> Device CITY <br /> Device Type Current Total Size Le ngth at EOL Tola I <br /> SLCLoop Type: Class Total Standby: 0255480 Total Alarm: 2.56028 2 GHLFW 72.1 144.2 8 GHLFW 72.1 576.8 <br /> Device Addresses Used 100 Standby Hours: 24 Alarm Mins: 5 4 GHSLF177W @177Cd 268 1072Now_ 1 GES3.24WW @1SCd 30 30 <br /> Device Addresses Available: 100 AH Required: 6.14 AH Required: 0.14 2 GES3-24WW @15Cd 30 60 _ 1 GCS24CW @15Cd 97 97 LU <br /> Total Combined Standby&Alarm AmpHours Required: 6.28 _ 1 GES3-24WW @75Cd 80 80 3 GCS3.24WW @15Cd 58 174 <br /> Efficiency Factor: 205e 2 GCS3-24WW@15Cd 58 116 DEVICES 13 TOTAL A- 677.8 14 289 22.69 SITS > O <br /> _DEVICES 11 TOTAL mA- 14722 14 260 22.02 14722 * rM <br /> Required Battery AmpHours: 754 Total Wire Resistance(R) I (W L'2)`(R/ft) 1.49 I..L <br /> Total Wire Resistance R WL"2 Rift 1.34 Total Device Load,Amps I Total Cct Load 0.88 w <br /> Battery AmpHours Provided: B w ( ) ( )�(Rift) t P () ( ) <br /> Note:The cabinet will house two 8 AH or 18 AH batteries.The charging cfmdt is miteiI Total Device Load,Amps(1) (Total Cct Load) 1.47 Voltage Drop(E) (E=I*R) 1.31 > <br /> up to two 55 AH batteries. Voltage Drop(E) (E=1•RI 1.96 EOL Voltage 22.69 J <br /> PM ER <br /> Voltage ?A-E 22.02c C., NAC N2-2 Alarm Alarm Wire Wire Voltage <br /> dim Circv <br /> CIRCUIT <br /> NAC NI-2 Alarm Alarm wine Wire Voltage CITY Device Type Current Total Size Length at EOL To. U) <br /> Q E V t e Ep OTY <br /> Davics 7ww12 GHLFW 72.1 865.2 1 Do <br /> GHLFW 721 286A 1 GES3-24WW @15Cd 30 30 N <br /> NAC Circuit Configuration&Voltage Drop EHA-SILVER VIEW 11/22/2024 2 GHSLF177W @177Cd 268 536 1 GCS3-24WW @15Cd 58 58 <br /> -'* GES3-24WW@15Cd 30 90 DEVICES 14 TOTAL mA- 9532 14 �7 111111111111111111111111!2.69 953.2 �M <br /> 1 WGES24-75WR@75Cd 112 112 W WZ <br /> 1 GBIO.24-EXISTING 100 100 Total Wire Resistance III (WL•2)•(Rift) 1.38 <br /> Usage:1 Notification Descriptbrc fNAC FP-1 2 GCS3-24WW @15Cd 58 116 Total Device Load,Amps(1) (Total Cct Load) 0.95 O Z <br /> 1 GCS24CW @15Cd 97 97 Voltage Drop(E I (E.I-w 1.31 = U)LU Z <br /> DEVICES 14 TOTALmA= 1339.4 14 218 22.49 1339.4 EOL Voltage 24-E) 22.69 Q= <br /> xl45olid 3.19 311 1.984 1.142 18.13 16 <br /> �Iarm Ala mn Wire Wine Voltage <br /> Total Wire Resistance(R) (WL'2)'(R/ft) 1.12 _ =Q <br /> _ Total Device Load,Amps(1) )[ (Total Cct Load) 1.34 Q Q <br /> •10 GHLFW 72.1 721 <br /> Voltage Drop(E) (E=I`R) 1.51 r <br /> 1 User Defined GES3-24WW @30cd Strobe 0.000000 0.000000 0.030000 0.030000 1 GCS3-24WW@15Cd 58 58 rrt LLI� c) <br /> 1 User Defined GES3-24WW@75cd Strobe 0.000000 0.000000 0.080000 0.080000 EOL Voltage 24-E 1 GCS3.24WW 75Cd 108 108 V <br /> 2 User Defined GEC3-24WW@35cdHom Strobe 0.000000 0.000000 0.134000 0.268000 DEVICES 12 TOTAL A- 721 14 294 22.94 721 Z LL r� <br /> 1 User Defined GEC3-24WW 30cd Ho.Strobe 0.000000 0.000000 0.070000 0.075600 • • rW <br /> 1 User Defired GEC3-24WW @110cd Hom Strobe 0.000000 0.000000 0.189000 0.189000 12 GHLFW 72.1 1612 Total Wire Resistance(R) (WL*2)"(R/ft) 1.47 (n > <br /> 7 User Defined GHLFW Low Fre uen Sounder 0.000000 0.000000 0.072100 0.504700 1 GEC3-24WW @15Cd 58 58 Total Device Load,Amps(1) (Total Cct Load) 0.72 W <br /> 1 GES3-24WW @15Cd 30 30 Voltage Drop(E) IS=I-R) 1.06 O <br /> �ieviCaS 14 TOTAL mA= 9532 14 241 22.81 9532 SOL Voltage 24-E) 22.94 <br /> Total Stan : 0.00000 Total Abami 1.14170 Total Wire Resistance(R) (WL"2)"(Ulf) 1.24 <br /> fr W <br /> Total Device Load,Amps(1) (Total Cct Load) 0.95 'a GHLFW 72.1 576.8 <br /> ))r Voltage Drop(E) (E=I*R) 1.19 1 GCS3.24WW @150dleeer <br /> EOL Voltage 24-E) F 22.81 Alarm Alarm wine Wire Voltage Circuit 1 GCS24CW @15Cd 97 97 w <br /> ***RECOMMENDED MINIMUM BATTERY SIZE=12VDC 8.0 AMP-HOUR*** 1,_ ots ze a GCS3.24WW @15Cd C <br /> U GHLFW F 72.1 2 DEVICES 13 TOTAL mA- 8052 14 307 22.57 905.E U-I <br /> IW <br /> 1 GCS3-24WW @15Cd 58 58 > <br /> w v DEVICES 13 TOTALmA= 923.2 14 2 Total Wire Resistance(R) (WL 2)'(R/ft) 1.58 W A <br /> Total Device Load,Amps(1) (Total Cct Load) 0.91 �/1 <br /> - ) <br /> m u: _ Total Wire Resistance(R) (WL'2)•(R/It) 1.36 Voltage Drop(E (E=I*R) 1.43 <br /> «N_ Total Device Load,Amps(1) (Total Cet Load) 0.92 EOL Voltage 24-E) 22.57 <br /> E Voltage Drop(E) (E=I'R) 1.25 SCALE:NOT TO SCALE <br /> IL y EOL Voltage 24-E) 22.75 DRAWN BY: <br /> 1;a D. GARCIA <br /> y o DESIGNED BY: <br /> >-a L. ALLEN <br /> WS TAHARKA MUHAMMAD DATE:11 20 24 <br /> a>i NICET LEVEL IV BACKROUND PUN PROVIDED BY <br /> c00. SYSTEM CALCULATIONS CERT. 138245 EXP. 01/07/2026 JOB NUMBER:76619-1 <br /> 'J SHEET <br /> W r FA-03 <br /> Proprietary & Confidential, Copyright 2012 by Guardian Security Systems, Inc. All Rights Reserved <br />