S <br /> I <br /> PIPING SYSTEMS PLUMBING LEGEND <br /> ME fglDmxO xelFa KNx N 1xE Exlia[w.w n,wnnsE I- <br /> - APPLICABLE PLUMBING CODE:UPC 2021 Q �¢ <br /> 11 0. 10 8 7 6 5 4 3 2 1 — ALL WASTE PIPING,CONDENSATE PIPING&STORM DRAIN PIPING TO CWV COMBINATION WASTE &VENT <br /> BE SLOPED AT 2%MIMIMUM UNLESS OTHERWISE NOTED. GW GREASY WASTE/SANITARY SEWER W �7 0�°® @� y1 <br /> K K - SURFACE MOUNTED PIPING WILL NOT BE ACCEPTABLE IN FINISHED ROOMS OR COOLERS.PIPING AND J <br /> CONDUIT OF ALL TYPES SHALL BE CONCELAED WITHIN WALLS, FLOORS,OR CEILINGS(INCLUDING WASTE/SANITARY SEWER d p \ 2 <br /> )( — CONDENDSATE DRAIN LINES,WATER HEATER PRESSURE RELIEF LINES AND SODA LINES.) VENT E_ <br /> Iq1? <br /> INSULATE ALL INTERIOR PIPING;STORM DRAIN,HOT,COLD RECIRC,AND <br /> X CONDENSATE PER SEPCIFICATION SECTION 22 07 00. COLD WATER y ® � <br /> — PIPING IN ROOF TRUSS SPACE TO BE RUN PEPPENDICULAR OR PARALLEL TO BUILDING JOIST OR GIRDERS. — — HOT WATER <br /> X FOR PASSING BELOW SOLID GIRDERS MOUNT PIPING 6'MAXIMUM FROM BOTTOM OF GIRDER.DO NOT BLOC V <br /> — — — - — X LIGHTING&SKYUGHTS --- --- HOT WATER CIRCULATION <br /> GENERAL MECHANICAL NOTES A AIR <br /> C CONDENSATE DRAIN <br /> — M.C.SHALL ENSURE ALL ROOF TOP EQUIPMENT IS LABELED CORRECTLY AND MATCH CALLOUTS ON�PLN ON G GAS <br /> THE Is <br /> &OUT OF THE BUILDING.THIS INCLUDES HVAC UNITS AND EXHAUST FAN.AND LOCATED WHERE EASILY VISIBLE FROM THE <br /> SHOULD BE rJ2 NITROGEN Y 3 _$EEEOaaa <br /> IN 6"BLOCK LETTERING IN BLACK COLOR HE ROOF HATCH. �y <br /> H N — MAINTAIN A MINIMUM OF 10'-0'BETWEEN EXHAUST OUTLET AND UNIT FRESH AIR INTAKE. $ SOFTENED COLD WATER O <br /> COORDINATE ALL MECHANICAL DUCTWORK LOCATIONS WITH ELECTRICAL EQUIPMENT.NO DUCTWORK WILL BE rr �Q1p <br /> H <br /> ALLOWED TO RUN OVER THE TOP OF ELECTRICAL DISTRIBUTION EQUIPMENT OF PANELS HARD COLD WATER W <br /> DIMENSIONS ARE TO COLUMN ONES. SD —SD— SD — STORM/OVERFLOW DRAIN <br /> I a I — APPLICABLE BUILDING CODEABC 2021 SSD SIPHONIC STORM DRAIN F--I <br /> 4- APPLICABLE MECHANICAL CODE:IMC 2021 <br /> APPLICABLE ENERGY CODE:IECC 2021 RO RO— FILTERED (RO) COLD WATER W <br /> — PROVIDE TIE DOWN FOR ALL FLUES&VENTS OF 3'OR TALLER. GAS COCK <br /> — FIELD VERIFY EXISTING FIRE SPRINKLERS AND DUCT DETECTORS. REINSTALL AND RECONNECT DUCT <br /> DETECTORS OR REPLACE WITH EQUAL. CONTROL VALVE — 2 WAY <br /> �u — ALL CONDENSATE PIPING TO BE SLOPED AT 2%MINIMUM UNLESS OTHERWISE NOTED. CONTROL VALVE — 3 WAY V 1 <br /> — RUN PIPING IN TRUSS SPACE PERPENDICULAR OR PARALLEL TO BUILDING JOIST OR GIRDERS.FOR PASSING <br /> BELOW SOUD GIRDERS MOUNT PIPING 6"MAXIMUM. FROM BOTTOM OF GIRDER.DO NOT BLOCK LIGHTING RPPB/RPZ <br /> F AND SKYLIGHTS T1 STRAINER <br /> D 4 THERMOMETER <br /> UNION <br /> ® I N VALVE - CHECK <br /> VALVE - GATE <br /> E E VALVE - PRESSURE REDUCING (PRV) <br /> ® GAS SIZE CHART MIXING VALVE <br /> PRESSURE PRESSURE MAX DEVELOPED 0- PRESSURE GAUGE <br /> PSI DROP LENGTH (FEET) <br /> D D7 2 TO 1.0 750 AUTO AIR VENT <br /> PIPE SIZE(UPC) MAX LOAD (MBH) E CAP OFF <br /> FOR WORK IN THIS AREA 1/2" 146 GAS CALCULATIONS A.F.F. ABOVE FINISH FLOOR o <br /> II SEE PLAN FOOD COURT <br /> ON THIS SHEET. 3/4" 305 EXISTING LOAD A.H.J. AUTHORItt HAVING JURISDICTION o <br /> YYYY 1" 575 9,820,000 B.F.F. BELOW FINISH FLOOR <br /> REMOVED LOAD Co CLEAN OUT <br /> X 1-1/4" 1,181 UH-12-14 225,000 � <br /> CONT. CONTINUATION <br /> DEMO EXISTING 1-1/2" 1,770 ADDED LOAD CW COLD WATER <br /> ® UNIT HEATERS RH-12,13 250.000 <br /> e' UH-12-14 2" 3,408 TOTAL GAS LOAD 9,845,000 CWV COMBINATION WASTE &VENT <br /> + 1 2-1/2" 5432 FCO FLOOR CLEAN OUT <br /> 3" 9,603 (E)6 " GAS SERVICE ACCEPTABLE 02 PSI G.0 GENERAL CONTRACTOR <br /> G.V GATE VALVE <br /> '�- 4" 19,586 GW GREASE WASTE m <br /> 1 �` 6" 57,376 GAS SIZE CHART H&CW HOT& COLD WATER <br /> 8„ 117,886 HW HOT WATER <br /> 11 0 0 PRESSURE PRESSURE MAX DEVELOPED IN. WC INCHES OF WATER COLUMN <br /> /� PROVIDE ONE OF FOLLOWING IN WC DROP LENGTH (FEET) / <br /> 44 A REGULATORS AT EACH PIECE OF 7 TO 6.5 100 MBH 1,000 BRITISH THERMAL UNITS HR. <br /> EQUIPMENT WITH VENT TO OUTSIDE M.0 MECHANICAL CONTRACTOR w <br /> III OR VENT LIMITER ON MAXITROL PIPE SIZE(UPC) MAX LOAD (MBH) <br /> III PSI POUNDS PER SQUARE INCH y <br /> SENSUS MODEL - <br /> #496 1/2" 45 RN ROUGH INSTALLATION <br /> 9 7 8 5 4 3 2 0 1 PIPE SIZE- 3/4" OR 1" 3/4" 94 RPPB REDUCED PRESSURE PRINCIPLE <br /> o ORIFICE - 3/8" <br /> SPRING - GREEN 1" 177 BACKFLOW PRLVENTER o <br /> KEY FLOOR PLAN FOR GAS LOAD UP TO 760 MBH 1-1/4• 363 RPZ REDUCED PRESSURE ZONE ASSEMBLY o <br /> SCALE: 1 32 = tR MAXITROL MODEL: 1-1 2" 544 BACKFLOW PREVENTER w <br /> GAS LOAD UP TO 340 MBH / SCO SURFACE CLEAN OUT Z <br /> PIPE SIZE O 3/4" OR 1" 2" 1,048 S.S. SANITARY SEWER � <br /> 2-1/2" 1,672 7YP. TYPICAL a <br /> GAS LOAD BETWEEN 340 MBH AND U UNION <br /> 1000 MBH 3" 2,956 325-7AL210D VTR VENT THRU ROOF <br /> -. <br /> (E)1-1/4" (E)1-1 4" PIPE SIZE 1-1/4" OR 1-1/2" 4 6,032 W. WASTE <br /> c (E)(925 MBH) (E)(675 MBH) •ALL GAS PRESSURE REGULATORS TO 6" 17,683 WCO WALL CLEAN OUT <br /> G BE RATED FOR 5 PSI. 8" 36,348 WHA WATER HAMMER ARRESTER A M Lo <br /> C f7 p p PO <br /> 1 1,4 INFRARED HEAT EQUIPMENT SCHEDULE - OWNER SUPPLIED A W <br /> (E)(22 MBH �] a I t- <br /> (250 HD om <br /> SYMBOL ITEM SERVES MFR/# DESCRIPTION ELECT. WEIGHT REFERENCE REMARKS NOTES <br /> RH-12 INFRARED FOOD COURT DETROIT TWO-STAGE INFRARED TUBE HEATER, 82-125 MBH 120V/10 190# PLAN ME-1 T'STAT W/LOCKING COVER (2) O a� yam, <br /> (E)1 HEATER RADIANT INPUT, 40' LENGTH ALUMINIZED TUBE W/STANDARD 1.3 FLA PROVIDED & INSTALLED BY M.C. Zp W <br /> (125 MBH) (E)(150 MBH) ,�-i ',�W <br /> a7 HL3 ALUMINUM REFLECTOR. CONTROLLED BY T'STAT. 28,62/M F Z <br /> G (125 MBH) MOUNT EMITTER TUBE 0 20' A.F.F. w o z O <br /> RH RH-13 INFRARED FOOD COURTDETROIT TWO STAGE INFRARED TUBE HEATER, 52-125 MBH DO W x <br /> 120V/10 160# PLAN M-1.1 T'STAT W/LOCKING COVER (2) Q w rn 04 a w <br /> 13 SEE DETAIL 28 62 HEATER RADIANT INPUT, 30' LENGTH ALUMINIZED TUBE, W/STANDARD 1.3 FLA PROVIDED & INSTALLED BY M.C. z <br /> HL3 ALUMINUM AND ONE-SIDE REFLECTORS. CONTROLLED 28,62/M <br /> 1" BY T'STAT. MOUNT EMITTER TUBE 0 17'A.F.F. <br /> (125 MBH) <br /> GENERAL NOTES: <br /> — — B - M.C. TO PROVIDE CONTROL WIRE AND CONDUIT FOR T'STAT. - T'STAT TO BE MOUNTED ®+78"A.F.F. UNLESS NOTED OTHERWISE. Z W <br /> W z <br /> rH w <br /> RZ SEE DETAIL 28 62 W <br /> - ELECTRICAL LEGEND <br /> - ELECTRICAL PLAN NOTE: CANOPY TIRE INSTALL ROOF E-I w <br /> SINGLE POLE SWITCH, +42" CO <br /> a = w wM O <br /> O EXISTING RADIANT HEATER TO BE REMOVED. E.C. TO REMOVE $a SUB-LETTER INDICATES FIXTURE CONTROLLED, +42" '� Q W W� <br /> T �� EXISTING ELECTRICAL DEVICES AND ASSOCIATE FEEDER TO SOURCE. a .--I �Z)CO <br /> A REUSE EXISTING CIRCUIT FOR NEW RADIANT HEATERS AS SHOWN. $D THREE POLE SWITCH, +42" Q Z O <br /> / FIELD VERIFY. [x] W <br /> OO JUNCTION BOX, SIZE AND TYPE PER CODE F+"I <br /> MOTOR CONNECTION AS REQUIRED GAS TO RH. L)SIZE PER PLAN. <br /> - �� ® DUPLEX RECEPTACLE, +18" OR AS NOTED <br /> a IJ Q x <br /> FUSED DISCONNECT, COORDINATE W/EQUIPMENT SUPPLIER L) E"EE—i <br /> EY NON-FUSED DISCONNECT, COORDINATE W/EQUIPMENT SUPPLER VENT TO OUTSIDE 3z <br /> c CONDUIT IN CEILING OR WALL, 1/2" MIN. PRV W CD <br /> �.�.I <br /> ' CONDUIT UNDERGROUND OR FLOOR, 3/4" MIN. El <br /> El o~ F�1 0 O pax] <br /> F� HOME RUN TO PANEL WITH CIRCUIT NUMBER, SLASHES W Q_ O <br /> INDICATE NUMBER OF CONDUCTORS /y� BURNER Q 0 <br /> `- ICNDICAMEfALLICECONDUIT OPVC�OTHER <br /> PLASTIC ON!'DUIt1/2"C PROVIDE CAPPED TESTING TEE DRIP LEG pW <br /> T FOOD COURT MINIMUM 10 PIPE DIAMETERS <br /> GAS & ELEC PLAN —{ ISOLATED GROUND OR GROUND CONDUCTOR AWAY FROM PRV INTAKE ANDWz <br /> W <br /> T SCALE: t/t6" FLEXIBLE CONDUIT CONNECTION AS REQUIRED OUTLETRADIANT HEATER GAS PIPING m� <br /> = t-o" � 3 <br /> a� EXISTING PANEL <br /> E.C. ELECTRICAL CONTRACTOR SCALE: NONE o <br /> WP WEATHERPROOF CANOPY ROOF a za <br /> m HACR BREAKER IN NEMA ENCLOSURE. COORDINATE WITH EQUIPMENT SUPPLIER. 4"TYPE "B"VENT CAP W gw <br /> l NOTE: E o o a <br /> VERIFY MINIMUM o <br /> CLEARANCE TO 4"TYPE "B"VENT PIPE N <br /> COMBUSTIBLES. _ (/) �3 <br /> NONH <br /> w <br /> CAULK ARDENING 24"MIN. o, <br /> BEAM CLAMP CAN ROOFo_ <br /> oELECTRICAL GENERAL NOTES: J—BIRD NETTING Z a3 <br /> -"- (1) INFORMATION ON THE EXISTING INSTALLATION HAS BEEN OBTAINED FROM THE BEST T DECK TITE OBTAINED zo <br /> T SOURCES AVAILABLE BUT CAN NOT BE GUARANTEED ACCURATE IN ALL RESPECT. PRIOR "S"1 HOOK / FROM MBS O <br /> c� TO BID, IT IS THE CONTRACTOR'S RESPONSIBILITY TO VISIT THE SITE, THOROUGHLY 3/lb" CHAIN 12'MIN. / CEILING CLOSURE F+-I <br /> FAMILIARIZE HIMSELF. 1 I PLATE <br /> Permit#: M2409-033 CITY OF EVERETT PERMIT SERVICES REFL ICTQR / 4" SINGLE <br /> Site Address: 10200 19th Ave Se REVIEW DISCIPLIE:BUILDING IN ALL WORK SHALL PERFORMED TO CHANGE THE EXISTING ELECTRICAL WALL PIPE Q <br /> T INSTALLATION AS SHOWNN.. INCLUDE AS PART OF THE CONTRACT ALL RELATED WORK <br /> Owner: COSTCO WHOLESALE CORP BY:C.Beaman SUBJECT FIELD REQUIRED TO OBTAIN THE INDICATED RESULTS. ALL EXISTING WIRING, CONDUITS, 1 O <br /> App.Date: 9/10/2024 DATE:09/20/2024 INSPECTITI ON JUNCTION BOXES AND ALL OTHER ELECTRICAL EQUIPMENT AND DEVICES IN THE AREAS S.S. WIRE MESH VENT ADAPTER a <br /> Description: Costco 114 Food Court Heaters Upgrade STATUS:REVIEWED FOR PERMIT AFFECTED BY THE DEMOLITION AND THE NEW WORK SHALL BE REMOVED AND I / BY NETTING N <br /> p P9 RELOCATED AS REQUIRED. EXTEND ALL CONDUITS AND WIRING. REPULL NEW WIRES AS 1 / CONTRACTOR n <br /> REQUIRED. a N <br /> (3) ALL WORK ARE TO BE DONE SO AS NOT TO INTERFERE WITH THE WAREHOUSE'S TUBE/REFLECTOR BURNER TUBE ? I <br /> NORMAL OPERATION. ANY ELECTRICAL SHUTDOWN SHALL BE COORDINATED AND HANGER E-I M 1 <br /> SCHEDULED AS APPROVED BY THE STORE MANAGER OR COSTCO'S DESIGNATED <br /> REPRESENTATIVE. REFLECTOR VENTING a a <br /> (4) DO NOT RUN CONDUITS AND WIRES ON ROOF. <br /> CANOPY INFRARED HEATER DETAIL <br /> SCALE: NONE �'U <br />