My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2309 74TH ST SE 2024 Plans 2025-08-20
>
Address Records
>
74TH ST SE
>
2309
>
Plans
>
2309 74TH ST SE 2024 Plans 2025-08-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/20/2025 11:44:44 AM
Creation date
8/20/2025 11:44:17 AM
Metadata
Fields
Template:
Address Document
Street Name
74TH ST SE
Street Number
2309
Permit
B2405-003
Year
2024
Notes
CONVERT EXISTING SFR TO ADULT FAMILY HOME
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
s.i <br /> GENERAL NOTES <br /> CODE <br /> DESIGN IS IN ACCORDANCE WITH THE 2018 INTERNATIONAL RESIDENTIAL CODE(I.R.C.) <br /> ADULT FAMILY HOME <br /> A DWELLING,LICENSED BY THE STATE OF WASHINGTON DEPARTMENT OF SOCIAL AND HEALTH SERVICES, <br /> IN WHICH A PERSON OR PERSONS PROVIDE PERSONAL CARE,SPECIAL CARE,ROOM AND BOARD TO MORE <br /> THAN ONE BUT NOT MORE THAN SIX ADULTS WHO ARE NOT RELATED BY BLOOD OR MARRIAGE TO THE <br /> PERSON OR PERSONS PROVIDING THE SERVICES.AN EXISTING ADULT FAMILY HOME MAY PROVIDE <br /> SERVICES TO UP TO EIGHT ADULTS UPON APPROVAL FROM THE DEPARTMENT OF SOCIAL AND HEALTH <br /> SERVICES IN ACCORDANCE WITH RCW 70.128.066. <br /> FOUNDATIONS <br /> EXTEND FOOTINGS TO FIRM UNDISTURBED SOIL,ASSUMED BEARING CAPACITY OF 1500 PSF.ALL <br /> EXTERIOR FOOTINGS SHALL EXTEND A MINIMUM OF 1'-6'BELOW ADJACENT EXTERIOR FINISHED GRADE. <br /> CAST-IN-PLACE CONCRETE <br /> F'c=3,000 PSI @ 28 DAYS.MINIMUM 5-1/2 SACKS OF CEMENT PER CUBIC YARD OF CONCRETE AND A <br /> MAXIMUM OF 6-314 GALLONS OF WATER PER 94#SACK OF CEMENT.NO SPECIAL INSPECTION REQUIRED. <br /> TOTAL AIR ENTRAINMENT SHALL NOT BE LESS THAN 5 PERCENT OR MORE THAN 7 PERCENT.MAXIMUM M <br /> SIZED AGGREGATES IS 1-1/2 INCHES.MAXIMUM SLUMP IS 4INCHES.ALL REINFORCING STEEL DOWELS, Q <br /> ANCHOR BOLTS AND OTHER INSERTS SHALL BE SECURED IN POSITION PRIOR TO POURING CONCRETE. (V <br /> ANCHOR BOLTS FOR PRESSURE TREATED SILL PLATES TO FOUNDATION WALLS TO BE%'DIAMETER WITH 00 <br /> 7 INCH MINIMUM EMBEDMENT INTO CONCRETE AND MAXIMUM SPACING OF 2 FEET ON CENTER UNLESS <br /> NOTED OTHERWISE ON THE PLANS.MINIMUM 2 BOLTS PER SILL PLATE PIECE.ONE BOLT TO BE PLACED <br /> WITHIN 61NCHES OF EACH END OF THE SILL PLATE. C/)j <br /> CARPENTRY =�! <br /> ALL GRADES SHALL CONFORM TO W WPA GRADING RULES FOR WESTERN LUMBER,LATEST EDITION. Z <br /> PROVIDE CUT WASHERS UNDER ALL NUTS AND BOLTS BEARING AGAINST WOOD.ALL WOOD IN CONTACT It <br /> ® - WITH CONCRETE SHALL BE PRESSURE TREATED PER PRESERVATIVE TREATMENT NOTE.FASTENERS O w <br /> INSTALLED IN PRESERVATIVE TREATED WOOD SHALL BE HOT-DIPPED GALVANIZED PER I.R.C-SECTION Q <br /> - R319.3.NAILING SHALL CONFORM WITH I.R.C.TABLE R602.3(1)&R802.10 OR I.B.C.TABLE 2304.9.1.ALL C__) Q LU <br /> ® ® STRUCTURAL LUMBER SHALL BE AS NOTED BELOW: O <br /> JNW <br /> 2x STUDS HEM-FIR#2 Fb=850 PSI <br /> 2X FLOOR&ROOF JOIST HEM-FIR#2 Fb=850 PSI <br /> 4z BEAMS DOUG-FIR/LARCH#2-Fb=875 PSI y <br /> 6z BEAMS DOUG-FIRMRCH#2-Fb=850 PSI \ <br /> COLUMNS M -DOUG-FIRRCH#2Fb=875 PSI o LL <br /> LUMBER NOT NOTED DOUG-FIRILARCH#2-Fb=850 PSI zi!p p <br /> .. .. - <br /> MISCELLANEOUS HANGERS TO BE PROVIDED BY SIMPSON COMPANY.ALL HANGERS SHALL BE FASTENEDc z u <br /> TO WOOD WITH PROPER NAILS ALL HOLES SHALL BE NAILED MACHINE BOLTS TO BE A 307 ANCHOR <br /> BOLTS INTO CONCRETE SHALL BE%'DIAMETER WITH 71NCHES OF EMBEDMEND INTO CONCRETE UNLESS Oa <br /> .. <br /> ... .... . ...... ., .• .. .. ER 621N LAMINATED STUDS <br /> NOTED OTHERWISE ON THE PLANS.ALL NAILS SHALL BE COMMON WIRE NAILS.NAILING SHALL BE IN z R <br /> .. . .. . ........::.' .. .. .,.... .. . .. .. ... .. SHALL BE NAILED WITH <br /> ()ROWS 16d COMMON NAIL � O.C. <br /> • ,• i z z ACCORDANCE WITH I.B.C.SCHEDULE.16d COMMON NAIL DIAMETER-0.1 INCH).LA y N <br /> H2 R S 6' � <br /> t f f w p <br /> FLOOR SHEATHING <br /> SHEATHING SHALL BE'Y INCH TONGUE&GROOVE,A.P.A.RATED SHEATHING.SPAN RATING%WITH y <br /> LONG DIMENSION PERPENDICULAR TO SUPPORTS.UNLESS NOTED OTHERWISE NAIL WITH 10d COMMON , i a o¢o i <br /> NAILS AT 61NCHES ON CENTER A7 SUPPORTED PANEL EDGES a 10 INCHES ON CENTER A7 INTERMEDIATE m <br /> SUPPORTS.THE FLOOR SHEATHING SHALL BE GLUED TO THE JOIST AND THE TONGUE AND GROOVE <br /> JOINTS WITH AN APPROVED ADHESIVE. i u `fi $ <br /> u a 8 r <br /> ROOF SHEATHING E s a E g <br /> -o a a' <br /> SHEATHING SHALL BE�/,s a A.P.A.RATED SHEATHING.SPAN RATING'A,.INSTALLED WITH LONG DIMENSION � <br /> ACROSS SUPPORTS.PANEL END JOINTS SHALL OCCUR AT SUPPORTS.NAIL PANEL EDGES WITH 8d NAILS <br /> AT 4 INCHES ON CENTER AND 10 INCHES ON CENTER AT INTERMEDIATE SUPPORTS. } <br /> J_ <br /> WALL SHEATHING cC <br /> SHEATHING TO BE%"A.P.A.RATED SHEATHING.SPAN RATING%.PANEL END JOINTS SHALL OCCUR AT G <br /> I ®mil T G I T I ®I SUPPORTS.NAIL PANEL EDGES NAILS AT W INCHES ON CENTER AND 10 INCHES ON CENTER AT Q <br /> INTERMEDIATE SUPPORTS UNLESSSS NOTED <br /> ED OTHERWISE ON THE DRAWINGS, LL. <br /> PROPOSED INTERIOR ALTERATION REINFORCEMENT J <br /> fy=40,000 PSI FOR#5&SMALLER Q <br /> fy=60,000 PSI FOR#5&LARGER Q <br /> NOTE:ALL BOLTS,WASHERS,NAILS,SCREWS,HANGERS AND FRAMING STRAPS THAT COME INTO Q <br /> ��/p��'�I�\� CONTACT WITH ACQ TREATED LUMBER SHALL BE STAINLESS STEEL OR HOT-DIPPED GALVANIZED STEEL. W <br /> QR I E ._C__-_. ~0 <br /> Additional Pei Are Required tom` i='�/ `ry!i WALL NOTES: d <br /> HARGETT MARIANNE A For This Project To include: I NAIL SPACING o O <br /> NEW 2X6 NAIL TOPIBOTTOM nd�IX <br /> 250g 74TH 5T SE, EXTERIOR WALL SIZE EDGES STUDS PLATE IZ n. <br /> EVERETT, WA g8205 © Plumbing [1 Sprinkler <br /> © Mechanical ❑Flre Alarm APPROVED <br /> [] Electrical Office of Community,Planning 6 Economic Development 1. 3'16 A.PA.RATED PLYWOOD OR ORIENTATED STRAND BOARD(O.S.B.) Document date: <br /> PLANNING DEPARTMENT ON ONE SIDE OF WALL.NAILS SHALL BE Ed COMMON(0.131' <br /> `/�'� ADDRESS <br /> DIAMETER). <br /> SITE / D a/ �E: DATE: 2' ALL PANEL EDGES BLOCKED WITH 2-INCH NOMINAL FRAMING.INSTALL <br /> PANELS EITHER HORIZONTALLY OR VERTICALLY FOR PLYWOOD OR <br /> A.P.A.RATED SHEATHING,GYPSUM SHEAR WALLS SHALL BE Revlelone: <br /> INSTALLED WITH THE SHEETS RUNNING HORIZONTALLY.SPACE NAILS <br /> 250g 74TH 5T , This approval only applies to @ 12 INCHES ON CENTER @ INTERMEDIATE SUPPORTS. Lv` <br /> PP Y PP 3. %"DIAMETER ANCHOR BOLTS SHALL BE 10 INCHES LONG SPACED A <br /> EVERETT, WA g8205 the work being performed under MAXIMUM OF 24 INCHES ON CENTER.WASHERS TO BE GALVANIZED <br /> Permit#A 24 n 5-Ina OR STAINLESS STEEL. JUN 2 4 2024 <br /> 4. REFER TO PLANS AND SECTIONS FOR ANCHOR BOLT SIZES,SPACING, <br /> and does not recognize any PLATE&NAILING ETC. C Y OF E VERE t <br /> F /` R� L I � N O. existing structure that may not <br /> l� armit sorvica$ <br /> meet zoning Code. INDEX OF DRAWINGS <br /> 003g8700200402 SHEET# DESCRIPTION <br /> EV,:.RETT FIRE DEPT.REVIEW <br /> PPROVED AO SITE PLAN <br /> ❑dPPROVED WITH CHANGES NOTED <br /> ❑RF.VISEAND RESUBMIT Al COVERSHEET <br /> 0 REJECTEO: jn <br /> ❑SEE ATTACHED CHECKLIST/HANDOUT 1S-UT A2 ALTERATION 2018 WSEC&AFH NOTES VZ <br /> The issuance of a permit shall not A3 FASTENING SCHEDULE g <br /> be construed as authority to violate, <br /> cancel or set aside any provision of <br /> the Everett Fire Code or other A4 DETAIL SHEETS u,_ <br /> applicable regulations or laws.The Z <br /> issuance of a Permit based on A5 EXISTING FLOOR PLAN o Q <br /> construction documents and other <br /> data shall not prevent the Fire Code A6 EXISTING ELEVATIONS Cffical from requiring the Correction <br /> of errors. A7 PROPOSED MAIN FLOOR PLAN&RAMP PLAN <br /> a <br /> A8 PROPOSED ELEVATIONS,DECK PLAN,FRAMING&FOUNDATION, A <br /> BUILDING SECTION <br /> 7A5 <br /> 240024 <br />
The URL can be used to link to this page
Your browser does not support the video tag.