My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2600 FEDERAL AVE PORT OF EVERETT 2026-01-15
>
Address Records
>
FEDERAL AVE
>
2600
>
PORT OF EVERETT
>
2600 FEDERAL AVE PORT OF EVERETT 2026-01-15
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/15/2026 9:00:57 AM
Creation date
8/20/2025 1:20:17 PM
Metadata
Fields
Template:
Address Document
Street Name
FEDERAL AVE
Street Number
2600
Tenant Name
PORT OF EVERETT
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
527
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MATERIAL LIST <br /> ROOF: <br /> ROOFING. ... .... .... .EPDM 45 MIL. MEMBRANE — FULLY ADHERED BLACK <br /> OVER YZ" SECUROCK (AIR BARRIER COMPONENT) <br /> NOTE: TERMINATION BAR INSTALLED ON PERIMETER <br /> SHEATHING. .... ..... .3/4" CDX PLYWOOD (48/24) [23/32" APA RATED] <br /> FRAMING . .. .... ..... .2 x 8 DF#2 © 24"oc <br /> RIMS... . ... . ... . .... ..2 x 8 CONTINUOUS LVL 2.0E <br /> INSULATION. . .CAVITY: R-24 CELLULOSE BLOW—IN TO 7Y4" OVER CLASS <br /> 'A' MATERIAL (AIR BARRIER COMPONENT) <br /> ABOVE DECK: R-17 CONTINUOUS RIGID, LAYER ONE 1t/�", LAYER <br /> TWO 1Y2", TOTAL THICKNESS 3" <br /> NOTE: WHERE TWO OR MORE LAYERS OF RIGID <br /> INSULATION ARE USED, EDGE JOINTS SHALL BE <br /> STAGGERED. <br /> TESTED IN ACCORDANCE WITH ASTM E84 OR UL <br /> 723 AT A MINIMUM THICKNESS OF 4Y2". SEE <br /> ESR-3174. <br /> CEILING. . .... .... ... .SUSPENDED T—BAR (PER IBC 808.1) <br /> VENTING. .. .... .... . .NONE <br /> WALLS: <br /> SIDAG. ... . ... . .... . .76 SERIES LP SMARTSIDE PANEL T1-11 <br /> WITH GROOVES @ 8"oc — USE 4'x10' PANELS <br /> FASCIA. .... ... . ... . . .8Y8" HIGH SIDE TAPERED ON SIDES TO 5Y2" LOW <br /> SIDE, 5/8" NO GROOVE LP SMARTSIDE PANELI <br /> TRIM. .. . ... . .... .... . .1 x 4 FINGER JOINTED CEDAR AT CORNERS, <br /> WINDOWS, AND DOORS <br /> NOTE: 2"x2" GALV. FLASHING INSTALLED OVER SIDING <br /> AND UNDER CORNER TRIM <br /> FRAMING. . . . . . . . .EXT: 2 x 6 DF #3 or BETTER STUDS Q 16"oc <br /> INT: 2 x 4 DF Q 16"oc <br /> PLUMBING WALL TO BE 2 x 4 DF <br /> TOP PLATE. ... . ... . .2 x 6 CONTINUOUS (DF#2 OR LVL 2.OE) <br /> B 12 A BOTTOM PLATE. .... .2 x 6 DF <br /> Y4 <br /> INSULATION . .. .... .. .R-21 UNFACED FIBERGLASS BATTS <br /> 00 INTERIOR FINISH. ... . .5/8" VINYLWRAP SHEETROCK —FINISH & AIR BARRIER <br /> NOTE: VINYLWRAP SHEETROCK TO FULL HEIGHT ON <br /> EXTERIOR WALLS (AIR BARRIER COMPONENT) <br /> CAULK AT SKIRTING... .... .... . .SHIP LOOSE <br /> ROOF RIM/TOP PLATE MIN. (2) 2 x 6 DF #2 MOISTURE . .... .... .. .WRAP LOWER 12" OF BUILDING & CORNERS WITH <br /> *. ��'—'7HEADER OVER SIDEWALL PROTECTION MOIST—STOP. WRAP ENTIRE BUILDING WITH <br /> OPENINGS w/RIGID INSULATION BUILDING WRAP <br /> FILLER <br /> FLOOR: <br /> = c�CAULK = <br /> c� _ <br /> w AROUND = w COVERING. . . . . . . . . . . .Y8" VCT (TYP.) <br /> = WINDOWS CD = = <br /> w 0 <br /> J _ _j w DECKING. . . . . . . . . 1st: 23/32" APA RATED STURD—I—FLOOR <br /> Q z (AIR BARRIER COMPONENT) <br /> CD 2nd:Y4" U—PLY X — ENTIRE BUILDING <br /> �o o v j� FRAMING. . ... . ... . .. .2 x 8 DF #2 FLOOR JOISTS AT 16"oc <br /> I _ - — <br /> � DOUBLE � o RIMS. .. .... .... ... . . .2 x 8 CONTINUOUS (LVL 2.OE) <br /> A HEADER I CIO INSULATION. . ... . ... .R-30 FIBERGLASS BATT USE 2 LAYERS R-15 <br /> AND SILL <br /> i_ u7 UNFACED FIBERGLASS BATT <br /> CAULK WALL I <br /> CORNERS FROM o BOTTOM COVER . ... . .CLASS "A" <br /> TOP TO BOTTOM <br /> � BASE . ... . ... . .... .. .4" RUBBER <br /> CAULK AT FRAME: <br /> FLOOR RIM/ <br /> BOTTOM PLATE TYPE . . . ... . ... . ... . .CONVENTIONAL (NO OUTRIGGERS, BUT WITH FULL <br /> LENGTH FRONT & REAR C—CHANNEL CROSS MEMBERS) <br /> MAIN RAIL. ... .... .. .W8x10 <br /> CUSTOMER APPROVAL AXLES. .. .... .... .... .2—BRAKE 0—IDLER W/ 8:00 x 14.5 14—PLY TIRES <br /> c-0 75�" ❑ APPROVED WITH ROCKERS <br /> 01 HITCH. . . .... .... .... .DETACHABLE <br /> N 9'-8" ❑ APPROVED EXCEPT AS NOTED <br /> G ADE ❑ REVISE AS NOTED AND RESUBMIT <br /> APPROVED By Date <br /> SECTION - A A PRELIMINARY <br /> SCALE: 1/2" = V-0" NOT FOR CONSTRUCTION <br /> COPYRIGHT 2021, BLAZER INDUSTRIES, INC. ■ MOBILE BREAK ROOM for.. Approved forConst: Job No: 20081 <br /> THIS MATERIAL IS THE EXCLUSIVE PROPERTY '�, — <br /> OF BLAZER INDUSTRIES, INC.AND SHALL ■■ 10 x 30 P O rt of EverettNorton Expansion File Copy: <br /> NOT BE REPRODUCED, USED, OR DISCLOSED <br /> TO OTHERS EXCEPT AS AUTHORIZED BY THE �� 06 INDUSTRIES,INC. Drawn By: LDG <br /> P.O.BOX489 www.blazerind.com A 2 <br /> WA Pacific Mobile Everett WA <br /> DATE REVISION BY WRITTEN PERMISSION OF BLAZER INDUSTRIES. ■■ 945OlneySt. ■ Aumsville,OR 97325-0489 Issue Date: 11-29-21 <br />
The URL can be used to link to this page
Your browser does not support the video tag.