I 12 ❑1 Y4 PACKAGE *SPVU* HIGH EFFICIENCY WALL MOUNT HEAT PUMP - SCHEDULE <br /> SINGLE POINT <br /> DD FAN SENSIBLE HEATING HEAT CONNECTION <br /> BLOWER BLOWER EFFICIENCY VENTIL. COOLING COOLING CAPACITY HEATING HEAT STRIPS <br /> UNIT BARD UNIT UNIT MOTOR AIRFLOW SPEED BLOWER GRADE VENTIL. (FA) FILTER OUTDOOR ENTERING ENTERING CAPACITY CAPACITY 47degs COP UNIT UNIT STRIPS OUTPUT MCA MOCP UNIT <br /> TAG UNIT MODEL NUMBER SIZE QTY TYPE CFM SETTING HP (FEG) DEVICE CFM TYPE EER (DB) TEMP (DB) TEMP (WB) TEMP BTUH BTUH BTUH 47degs HERTZ VOLTS PHASE KW BTUH AMPS AMPS WGT ADDITIONAL NOTES <br /> O O HP-1 W18HB-A04ZP4XXR 1.5 1 ECM 709 MED 1/3 ---- ECON ---- MERV-8 11.30 95 80 67 18,136 14,290 16,800 3.5 60 240 1 08 27,304 57 60 325 1,2,3,4,5,6,7,9,10,11 <br /> 01 <br /> ADDITIONAL NOTES: <br /> 1 - CAPACITY LISTED ABOVE ARE IN ACCORDANCE WITH ANS/ARI STANDARD 390-2003 FOR SPVU (SINGLE PACKAGE VERTICAL UNITS) SEQUENCE OF OPERATION: <br /> 2 - COMPLIES WITH EFFICIENCY REQUIREMENTS OF ANSI/ASHRAE/IESNA 90.1-2016. <br /> 3 - BARD THERMOSTAT #8403-060, 7-DAY PROGRAMMABLE 1- UPON A COOLING CALL FROM THE ROOM THERMOSTAT THE UNIT WILL BE IN ECONOMIZER OR MECHANICAL <br /> 4 - BARD INDOOR REMOTE SENSOR, #8403-067 COOLING MODE OR BOTH DEPENDING ON THE ECONOMIZER JADE CONTROLLER SETPOINTS. <br /> 5 - BARD CO2 SENSOR, #S8403-067 2- UPON A HEATING CALL FROM THE ROOM THERMOSTAT THE UNIT WILL BE IN MECHANICAL HEATING AND THE <br /> 4 - 2" PLEATED FILTER, MERV-8 ECONOMIZER WILL BE DISABLE, 2ND STAGE HEAT STRIPS WILL COME ON IF THE ROOM TEMPERATURE DROPS <br /> 5 - UNIT COLOR IS *BUCKEYE GRAY* BELOW ITS SETPOINT AND DURING DEFROST. <br /> 6 - HEAT STRIPS KIT WITH CIRCUIT BREAKER 7 PRE INSTALLED OUTDOOR THERMOSTAT, SET AT 40DEG'S & LAC CONTROL (R) OPT 3- CO2 SENSOR TO CONTROL THE VENTILATION MODE THROUGH THE OCCUPY CONNECTION AS REQUIRED BY ITS <br /> -10 - ECONOMIZER,WITH JADE CONTROLLER, ENTHALPY/TEMP SENSOR SET POINTS <br /> 11 - #BSDTIMER - TO PROVIDE A MEANS OF SHUTTING DOWN OF THE MECHANICAL HEATING AND COOLING SYSTEM, VIA DOOR SWITCH 4- THESE MODES WITH KEEP REPEATING AND REQUIRED BY THE THERMOSTAT. <br /> PLENUM VARIFICATION ** M.C. TO REFER TO INSTALLATION INSTRUCTIONS FOR START UP AND EQUIPMENT SET. <br /> ** M.C. TO CHECK SITE VOLTAGE AND SET CORRECT TAP ON TRANSFORMER. <br /> ** M.C. TO SET AND PROGRAM THERMOSTAT PER CUSTOMERS REQUIREMENTS. <br /> ** M.C. TO SET AND CHECK ECONOMIZER AND VENTILATION PRE PROJECT REQUIREMENTS <br /> SCALE: 1/2" = V-0" <br /> O O <br /> PLENUM #PWR139 <br /> O <br /> ____10-1 <br /> 0__ 1.5 TON 4 kW <br /> MECHANICAL NOTES: WALL HUNG <br /> -------------- 8 - HEAT PUMP <br /> WA - 2018 IMC WAC AND 2018 WSEC 1020 CFM MAX <br /> 1. VENTILATION PROVIDED VIA NATURAL VENTILATION IN ACCORDANCE WITH IMC SECTION 402 IN 8 <br /> LIEU OF DOAS REQUIREMENTS. [WSEC SECTION C 403.3.5 EXCEPTION 1] g <br /> 2. MECHANICAL EQUIPMENT INSTALLATION IN OR ON THIS BUILDING SHALL BE IN ACCORDANCE WITH g <br /> THE REQUIREMENTS OF IMC WAC CHAPTER 6 UNLESS OTHERWISE EXEMPTED. <br /> 3. DUCT MATERIAL IS 26 GA. GALVANIZED WITH 2.2" FSK INSULATION. DUCTWORK SHALL BE <br /> SUPPORTED. [IMC WAC SECTION 603] T <br /> PLENUM #PWS052 <br /> 4. ROUND FLEX DUCT SHALL BE UL LISTED CLASS 1, STANDARD 181 - FACTORY MADE AIR <br /> DUCTSAND AIR CONNECTORS.THE MINIMUM THERMAL PERFORMANCE SHALL BE AT R-6, AND O <br /> MEASURED IN ACCORDANCE WITH ATSM C 518 OR ATSM C 177 AT 75DEG F MEAN <br /> TEMPERATURE. INSTALLATION SHALL BE IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION <br /> INSTRUCTIONS. MECHANICAL PLAN- <br /> DEVELOPMENT 5. MATERIAL IN DUCTS SHALL HAVE A FLAME SPREAD INDEX OF LESS THAN 25, SMOKE OF 50. [IMC SECTION 602] <br /> SCALE: 1/4" = 1'-0" <br /> 6. LOW PRESSURE DUCT SYSTEMS SHALL HAVE LONGITUDINAL AND TRANSVERSE JOINTS, SEAMS <br /> AND CONNECTIONS OF SUPPLY AND RETURN DUCTS AND PLENUMS SECURELY FASTENED AND <br /> SEALED WITH WELDS, GASKETS, MASTICS (ADHESIVES), MASTIC-PLUS EMBEDDED-FABRIC MECHANICAL SYMBOLS <br /> SYSTEMS OR APPROVED TAPES INSTALLED IN ACCORDANCE WITH IMC WAC SECTION 603.9. <br /> 7. DUCT INSULATION SHALL COMPLY WITH IMC WAC SEC 604. SYMBOL DESCRIPTION <br /> 8. WHEN ISOLATION SLEEVES ARE USED AT LINE CONNECTIONS TO PLENUMS, THEY SHALL COMPLY ® 2'x2' SUPPLY AIR DIFFUSER <br /> WITH IMC WAC CHAPTER 6. <br /> 9. IF DIFFUSERS HAVE NO MANUAL DAMPERS, USE FLOW CONTROL AT WYES. TYPICAL AS NOTED ON TYPICAL DOOR SWITCH WITH 2'x2' RETURN AIR GRILLE <br /> PLAN. TIME DELAY WIRING FOR HEAT PUMPS <br /> 10. MINIMUM OUTSIDE AIR VENTILATION PER IMC WAC TABLE 403.3.1.1. THIS DRAWING IS SHOWN WITH A JUMPER WIRE <br /> INSTALLED ON TERMINALS#1 TO#2"DOOR -X SUPPLY DUCT w/DIAMETER INDICATOR <br /> 11. OUTSIDE AIR DAMPERS SHALL COMPLY WITH WSEC, SECTION C403.7.8. SWITCH JUMPER" WIRE.REMOVE JUMPER WHEN <br /> DOOR SWITCH IS INSTALLED,WIRED AS SHOWN. <br /> 12. ALL NEW SYSTEMS REQUIRE ECONOMIZERS UNLESS EXEMPTED BY EXCEPTIONS. [WSEC SECTION OT THERMOSTAT <br /> 403.5] O O <br /> 13. DOOR SWITCH CONTROLS SHALL BE INSTALLED IN ACCORDANCE WITH WSEC 403.4.1.6 AT ALL F---------�� 1� <br /> DOORS THAT OPEN TO THE OUTDOORS. I RRT Natural Ventilation rates per IMC Section 402 <br /> 14. MECHANICAL DRAWINGS SHOW DUCTWORK SIZES TO BE CLEAR INSIDE DIMENSION. i _Z7 <br /> W2® ®G room# name Az (sf) 4%(sf) openings check notes <br /> 15. ELECTRICIAN MUST VERIFY ALL ELECTRICAL REQUIREMENTS AND LOCATIONS. 3® Break Room 238 9.5 29.83 OK <br /> 16. CONTRACTOR SHALL ARRANGE ALL HVAC UNITS AND ASSOCIATED ITEMS FOR ACCESS W3® ®C <br /> CLEARANCES. 4® E® ®Y <br /> 17. THERMOSTAT SCHEDULING TO BE PERFORMED ON SITE BY OTHERS. 5® L <br /> ® ®Y1 DOAS is not provided due to the exception for areas with natural ventilation under 2018 WSEC C403.3.5 Exception 1. <br /> 18. ALL HVAC EQUIPMENT LEAVES FACTORY WIRED FOR 240 VOLT OPERATION. 6® ® Natural Ventilation is provided per20181MCSection 402.1, 402.2and 402.3. <br /> 19. THE ACCEPTABLE OPERATING RANGE FOR THE 240V & 208V TAPS ARE: DH B <br /> z® <br /> TAP RANGE I I 01 ® �W1 <br /> FIELD 8® Section 402.1-The Natural Ventilation shall be provided through the windows and exterior doors (SEE PLAN SHEETA-1 <br /> 240 253 -216 INSTALLED O O for location and sizing information). <br /> WIRES ADD NEW UNIT LOW VOLTAGE <br /> 208 220-187 TERMINAL TERMINAL BLOCK <br /> BARD <br /> 20. SITE MECHANICAL CONTRACTOR IS RESPONSIBLE FOR MAKING SURE THE RIGHT TAP IS BLOCK Section 402.2-The minimum openable area of these means of natural ventilation, shall meet the 4% of floor area <br /> CONNECTED FOR THE APPLIED SITE VOLTAGE. 8607-021 <br /> L--j DOOR SWITCH(FIELD SUPPLIED) requirement.The exterior windows and doors provide direct natural ventilation to the spaces at the perimeter of the <br /> SWITCH IS OPEN WHEN DOOR <br /> 21. AIR FILTERS IN HVAC UNITS OR SYSTEMS ARE TO BE CHANGED EVERY 30 DAYS BY OTHERS ON <br /> I <br /> SITE. IS IN THE OPEN POSITION <br /> I <br /> 22. REGISTER AIR FLOW TEST AND BALANCE OF HVAC SYSTEM TO BE PROVIDED AND PERFORMED BY -� SWITCHNTHE IS CLOSEDED WHEN <br /> OTHERS ON SITE WHEN REQUIRED. L IS IN THE CLOSED POSITION <br /> 23. HVAC SITE CONTRACTOR IS RESPONSIBLE FOR BALANCING THE SYSTEM. BALANCING SHALL BE IN THIS KIT WILL COMPLY WITH WSECC403-4.1.6 <br /> ACCORDANCE WITH IMC WAC 403.3.1.5. CUSTOMER APPROVAL <br /> ❑ APPROVED <br /> ❑ APPROVED EXCEPT AS NOTED PRELIMINARY <br /> ❑ REVISE AS NOTED AND RESUBMIT <br /> APPROVED By Date NOT FOR CONSTRUCTION <br /> COPYRIGHT2021, BLAZER INDUSTRIES, INC. ■ MOBILE BREAK ROOM for. Approved forConst: Job No: 20081 <br /> THIS MATERIAL IS THE EXCLUSIVE PROPERTY <br /> OF BLAZER INDUSTRIES, INC.AND SHALL ■■ �f✓�`j/�� 10 x 30 Port of Everett Norton Expansion File Copy: <br /> NOT BE REPRODUCED, USED, OR DISCLOSED <br /> TO OTHERS EXCEPT AS AUTHORIZED BY THE �� INDUSTRIES,INC. Drawn By: LDG <br /> DATE REVISION BY WRITTEN PERMISSION OF BLAZER INDUSTRIES. P.O.BOx489 ille,O az 325- 48 WA Pacific Mobile Everett WA <br /> ■■ 945 Olney St. ■ Aumsville,OR 97325-0489 � Issue Date: 11-29-21 M i <br />