My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2600 FEDERAL AVE PORT OF EVERETT 2026-01-15
>
Address Records
>
FEDERAL AVE
>
2600
>
PORT OF EVERETT
>
2600 FEDERAL AVE PORT OF EVERETT 2026-01-15
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/15/2026 9:00:57 AM
Creation date
8/20/2025 1:20:17 PM
Metadata
Fields
Template:
Address Document
Street Name
FEDERAL AVE
Street Number
2600
Tenant Name
PORT OF EVERETT
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
527
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
W. <br /> MODULAR BUILDING <br /> CHASSIS BEAM <br /> 18878 <br /> STEEL PIER PER PLAN& 30'-0" <br /> NOTES <br /> (5)16A6 PADS&STL PIERS @ 81"=27'-0' V-6" RENENS 9 27 2023 NON-STRUCTURAL SKIRTING(OPTIONAL) <br /> 0 <br /> 16x16 ABS PAD OR 12x24 P.T.PLANKS <br /> PER PLAN&NOTES,ON ASPHALT OVER _ <br /> COMPACTED GRAVEL PAD <br /> PIERIPAD SUPPORT <br /> 1'-0" <br /> LONGITUDINAL ANCHOR,3/Fl,EA END UPLIFTANCHOR,4/Fl,EASIDE <br /> � I II <br /> MODULAR BUILDING <br /> CHASSIS BEAM — <br /> SOIL ANCHOR STRAP 1-p' (4)SOIL ANCHORS,21F1,EA SIDE <br /> MM-32 W/BUCKLE <br /> SECOND SOIL ANCHOR STRAP IS <br /> REQUIRED TO GO TO NEXT RAIL (n <br /> WHEN PRIMARY ANCHOR STRAP >� <br /> EXCEEDS45° <br /> SOIL ANCHOR PER PLAN <br /> &NOTES ::3 <br /> m <br /> STRUCTURAL NOTES: <br /> (6 <br /> 1. GENERAL BUILDING DESIGN: 7 <br /> 1.1.VERIFY BUILDING DIMENSIONS PRIOR TO INSTALLATION OF FOUNDATION -0 <br /> 1.2.BUILDING RISK CATEGORY II ccO <br /> 1.3.AGEOTECHNICAL REPORT WAS NOT SUPPLIED BY THE OWNER FOR THE DESIGN OF G <br /> LATERAL ANCHOR THESE FOUNDATIONS.THE OWNER IS RESPONSIBLE FOR PROVIDING A SUITABLE <br /> Scale: 1/2"=1'-O" STABLE SUBGRADE FOR THE BUILDING FOUNDATION. 06 <br /> 2. DESIGN INFORMATION&LOADING: <br /> 2.1.BUILDING CODE IBC 2018,ASCE 7-16,WBC <br /> MODULAR BUILDING 2.2.ROOF LIVE LOAD 25 PSF,SNOW A <br /> CHASSIS BEAM 2 FLOOR LIVE LOAD 50 PSF OR 2,0001 CONC. <br /> 2.4.WIND CRITERION 100 MPH,EXP c,Krt=1.0 <br /> 2.5.SEISMIC CRITERION SD5=0.834,1e=1.0,SEISMIC CATEGORY,D <br /> 2.6.ASSUMED SOIL BEARING 1,500 PSF,SITE CLASS D(SOIL AT BOTTOM OF <br /> GRANULAR BASE) <br /> 3. CONCRETE: <br /> 3.1.DESIGN COMP.STRENGTH 2,500 PSI <br /> 3.2.REINFORCING YIELD 60 KSI g <br /> 3. MASONRY: w p <br /> SOIL ANCHOR STRAP MMA-71 3.1.8x16x8 UNITS ASTM C-90,GRADE N Lu <br /> 3.2.SET UNITS W/CORES VERTICAL,PER PLAN. a- <br /> F N <br /> AND BEAM CONNECTOR MMA-34 3.3.STACKS OF 3 OR LESS SINGLE CAN BE DRY-STACKED. VI g a <br /> 3.4.STACKS OF 4-6 UNITS TO BE DOUBLED DRY-STACKED W/EACH COURSE ROTATED 90 In =m <br /> °FROM COURSE BELOW. z u w <br /> 3.5.STACKS OF OVER 6 UNITS TO BE GROUTED FULL WITH(1)#4 IN EACH OF THE(4) p '- <br /> SOILANCHORPER � CJ p <br /> CELLS. <br /> PLAN&NOTES 4. WOOD: m <br /> 4.1.GENERAL MEMBERS TO BE HF-CONST GRADE OR BETTER. j 3 p -d o <br /> 4.2.BEAMS&POSTS TO BE HF#2 OR BETTER. > Do <br /> 4.3.MEMBERS EXPOSED TO EARTH,CONCRETE OR MA50NRYSHALL BE PRESSURE Z <br /> TREATED AND FASTENERS STAINLESS STEEL OR GALVANIZED. Q G8.2 <br /> 4.4.ALL FASTENERS IN TREATED WOOD SHALL BE GALVANIZED BOX NAILS OR STAINLESS LJJ STEEL COMMON. 0 <br /> S. SPECIALTY ITEMS:("MINUTE MAN PRODUCTS,INC."(800)438-7277 <br /> LONGITUDINAL ANCHOR N 3 <br /> W W W.MINUTEMANPRODUCTS.COM) <br /> Scale: 1/2"=V-0" 5.1.METAL PIERS: g <br /> 5.1.1. TO BE CAPABLE OF SUPPORTING 6,0001t <br /> 5.1.2. USE BOLTED CLIP CONNECTOR AT HEAD OF PIER TO MODULE CARRIAGE RAIL. <br /> 5.1.3. ATTACH BASE OF PIER TO CONCRETE WITH'SIMPSON'HD TITAN SCREWS OR Z <br /> TO PLASTIC OF WOOD PADS WITH#12 PAN-HEADED WOOD-SCREWS AT O <br /> MODULAR BUILDING OPPOSITE CORNERS OF PADS. Q <br /> CHASSIS BEAM 5.2.SOIL ANCHORS(BASED ON A MAXIMUM HEIGHT OF FINISHED FLOOR=48"ABOVE <br /> FOUNDATION SUBGRADE) Z <br /> 5.2.1. UPLIFT ANCHORS-AUGER ANCHORS PRE-DRILLED THROUGH PAVEMENT AND M 2 <br /> BASE INTO NATIVE SOILS MMA-92 OR GW2. Q 3 <br /> MM-32 CHOR STRAP O <br /> MM-32 W/BUCKLE 5.2.1. MMA-X-DRIVE ANCHORS INTO COMPACTED GRAVEL OR ASPHALT SUBGRADE m N <br /> MMA-35. a C7 <br /> STEEL PIER PER PLAN& 5.2.2. STRAlz <br /> PS ANCHOR HEAD TO RIM JOIST: W ZO <br /> 5.2.2.1. MMA-32 FOR STRAPS WRAPPED AROUND THE RIM BEAM W/BUCKLE. cc <br /> 5.2.2.2. MMA-71 FOR S <br /> NOTES TRAPS BOLTED TO RIM JOISTS W Z z w <br /> 5.2.2. STRAPS SHALL SET AT 30°TO 45°FROM HORIZONTAL.IF STRAPS ARE SET AT > Qa w m a <br /> a 16xl6 ABS PAD PER PLAN MORE THAN 45°TO OUTSIDE CARRIAGE RAIL INSTALL A SECOND STRAP TO THE Lu X w <br /> i &NOTES,ON COMPACTED NEXTADJACENT RAIL. L.L Z z O F- <br /> GRAVEL PAD 5.2.3. INSTALL ALL SPECIALTY ITEMS PER THE MANUFACTURER'S O ^' <br /> RECOMMENDATIONS. Q cc z 6 ry <br /> 5.2.4. CONNECT ANCHOR TIES TO BUILDING ONLYAFTER BUILDING IS FULLY BLOCKED O c Q Z o <br /> SOIL ANCHOR PER <br /> AND LEVELED. w 3 <br /> PLAN&NOTES 6. VENTING:(IF SKIRTING INSTALLED) O Z o m a o <br /> 6.1.PROVIDE A CLASS I VAPOR RETARDER OVER ENTIRE CRAWLS SPACE " m <br /> 6.2.PROVIDE VENTING TO RATIO OF I SOFT <br /> OF VENTILATION PER 1500 SQ.FT OF d <br /> CRAWLSPACE AREA. ^� m <br /> 6.3.PROVIDE MINIMUM OF ONE VENT NEAR EACH FOUNDATION CORNER FOR O o <br /> CROSS-VENTILATION. <br /> UPLIFT ANCHOR 7. ACCESS:(IF SKIRTING INSTALLED) m ¢ w <br /> Scale: l/2"=1'-0" 7.1.PROVIDE MINIMUM I8"x24"ACCESS TO THE UNDER FLOOR AREA. x w <br /> 7.2.PROVIDE 18"MIN.CLEARANCE FROM SUBGRADE TO UNDERSIDE OF ANY O 3 u <br /> UNTREATED WOOD MEMBER. p <br /> 7.3.PROVIDE 12"MIN.CLEARANCE UNDER FROM SUBGRADE TO UNDERSIDE OF ALL <br /> BUILDING MEMBERS. REVISION DATE: <br /> 8. SITE CONDITIONS: 12-21-2021 <br /> 8.1.FOUNDATION SUBGRADE IS 9-INCHES OF ASPHALT PAVING OVER 12-INCHES OF F 1 <br /> COMPACTED GRANULAR BASE OVER STABLE COMPACT SOIL. <br /> SHEET: 1 OF 1 <br /> SC07MLSON <br />
The URL can be used to link to this page
Your browser does not support the video tag.