Laserfiche WebLink
96 Ft Monopole Tower Structural Analysis February 28, 2022CCl BU No 880407 <br /> Project Number 2078679, Order 601554, Revision 0 Page 13 <br /> Description Elevation Offset Azimuth E E,x Enr En <br /> From Angle <br /> Centroid <br /> ft n oK K K K__ <br /> CCISeismic Samsung 61.00 0.00 0.0000 0.00 0.00 0.00 _ 0.00 <br /> telecommunications TYPE <br /> 7(1-5/8")From 0 to 85(564 <br /> to66ft) <br /> CCISeismic Samsung 51.00 0.00 0.0000 0.00 0,00 0.00 0.00 <br /> telecommunications TYPE <br /> 70-5/8")From 0 to 85(46ft <br /> to56ft) <br /> CCISeismic Samsung 41.00 0.00 0.0000 0.00 0.00 0.00 0.00 <br /> telecommunications TYPE <br /> 7(1-5/6")From 0 to 85(36ft <br /> to46ft) <br /> CCISeismic Samsung 31.00 0.00 0.0000 0.00 0.00 0.00 0.00 <br /> telecommunications TYPE <br /> 7(1-5/8")From 0 to 85(26ft <br /> to36ft) <br /> CCISeismic Samsung 21.00 0.00 0.0000 0.00 0.00 0.00 0.00 <br /> telecommunications TYPE <br /> 7(1-5/8")From 0 to 85(16ft <br /> to26ft) <br /> CCISeismic Samsung 11.00 0.00 0.0000 0.00 0.00 0.00 0.00 <br /> telecommunications TYPE <br /> 7(1-5/8")From 0 to 85(6ft <br /> to16ft) <br /> CCISeismic Samsung 3.00 0.00 0.0000 0.00 0.00 0.00 0.00 <br /> telecommunications TYPE <br /> 7(1-5/8")From 0 to 85(Ott <br /> to6ft) <br /> CCISeismic(15)belden 69.00 0.00 0.0000 0.01 0.00 0.00 0.01 <br /> 9207(5/16)From 0 to 72(66ft <br /> to72ft) <br /> CCISeismic(15)belden 61.00 0.00 0.0000 0.02 0.00 0.00 0.01 <br /> 9207(5/16)From 0 to 72(56ft <br /> to66ft) <br /> CCISeismic(15)belden 51.00 0.00 0,0000 0.02 0.00 0.00 0.01 <br /> 9207(5/16)From 0 to 72(46ft <br /> to56ft) <br /> CCISeismic(15)belden 41.00 0 00 0.0000 0.02 0.00 0.00 0.00 <br /> 9207(5/16)From 0 to 72(36ft <br /> to46ft) <br /> CC[Seismic(15)belden 31.00 0.00 0.0000 0.02 0.00 0.00 0.00 <br /> 9207(5116)From 0 to 72(26ft <br /> to36ft) <br /> CCISeismic(15)belden 21.00 0.00 0.0000 0.02 0.00 0.00 0.00 <br /> 9207(5/16)From 0 to 72(16ft <br /> to26ft) <br /> CCISeismic(15)belden 11.00 0.00 0.0000 0.02 0.00 0.00 0.00 <br /> 9207(5/16)From 0 to 72(6ft <br /> tol6ft) <br /> CC[Seismic(15)belden 3.00 0.00 0.0000 0.01 0.00 0.00 0.00 <br /> 9207(5/16)From 0 to 72(Oft <br /> to6ft) <br /> CCISeismic(4)commscope 69.00 0.00 0.0000 0.00 0.00 0.00 0.00 <br /> FXL 540 PE(1/2)From O to 72 <br /> (66ft to72ft) <br /> CCISeismic(4)commscope 61.00 0.00 0.0000 0.00 0.00 0-00 0.00 <br /> FXL 540 PE(1/2)From 0 to 72 <br /> (56ft to66ft) <br /> CCISeismic(4)commscope 51.00 0.00 0.0000 0.00 0.00 0.00 0.00 <br /> FXL 540 PE(1/2)From 0 to 72 <br /> (46ft to56ft) <br /> CCISeismic(4)commscope 41.00 0.00 0.0000 0,00 0.00 0.00 0.00 <br /> FXL 540 PE(1/2)From 0 to 72 <br /> (36ft to46ft) <br /> CC[Seismic(4)commscope 31.00 0.00 0.0000 0.00 0.00 0.00 0.00 <br /> FXL 540 PE(1/2)From 0 to 72 <br /> (26ft to36ft) <br /> CCISeismic(4)commscope 21.00 0.00 0,0000 0.00 0.00 0.00 0.00 <br /> tnxTower Report-version 8.1.1.0 <br />