Laserfiche WebLink
February 28, 2022 <br /> 96 Ft Monopole Tower Structural Analysis CC/BU No 880407 <br /> Project Number 2078679, Order 601554, Revision 0 Page 18 <br /> Dishes <br /> Description Face Dish Offset Offsets_ Azimuth 3 dB Elevation Outside <br /> or Type Type Horz Adjustment Beam Diameter <br /> Leg Lateral Width <br /> Vert <br /> ft ft ft <br /> VHLP1-23-1GR B Paraboloid w/Shroud(HP) From 1.50 0.0000 72.00 1.27 <br /> Leg 0.00 <br /> 3.00 <br /> VHLP1-23-1GR C Paraboloid w/Shroud(HP) From 1.50 0.0000 72.00 1.27 <br /> Leg 0.00 <br /> 3.00 <br /> VHLP2-23-1 GR C Paraboloid w/Shroud(HP) From 1.50 0.0000 72.00 2.17 <br /> Leg 0.00 <br /> 3.00 <br /> Load Combinations <br /> Comb. Description <br /> NO, <br /> 1 Dead Only <br /> 2 1.2 Dead+1.0 Wind 0 deg-No Ice <br /> 3 0.9 Dead+1.0 Wind 0 deg-No Ice <br /> 4 1.2 Dead+1.0 Wind 30 deg-No Ice <br /> 5 0.9 Dead+1.0 Wind 30 deg-No Ice <br /> 6 1.2 Dead+1.0 Wind 60 deg-No Ice <br /> 7 0.9 Dead+1.0 Wind 60 deg-No Ice <br /> 8 1.2 Dead+1.0 Wind 90 deg-No Ice <br /> 9 0.9 Dead+1.0 Wind 90 deg-No Ice <br /> 10 1.2 Dead+1.0 Wind 120 deg-No Ice <br /> 11 0.9 Dead+1.0 Wind 120 deg-No Ice <br /> 12 1.2 Dead+1.0 Wind 150 deg-No Ice <br /> 13 0.9 Dead+1.0 Wind 150 deg-No Ice <br /> 14 1.2 Dead+1.0 Wind 180 deg-No Ice <br /> 15 0.9 Dead+1.0 Wind 180 deg-No Ice <br /> 16 1.2 Dead+1.0 Wind 210 deg-No Ice <br /> 17 0.9 Dead+1.0 Wind 210 deg-No Ice <br /> 18 1.2 Dead+1.0 Wind 240 deg-No Ice <br /> 19 0.9 Dead+1.0 Wind 240 deg-No Ice <br /> 20 1.2 Dead+1.0 Wind 270 deg-No ice <br /> 21 0.9 Dead+1.0 Wind 270 deg-No ice <br /> 22 1.2 Dead+1.0 Wind 300 deg-No Ice <br /> 23 0.9 Dead+1.0 Wind 300 deg-No Ice <br /> 24 1.2 Dead+1.0 Wind 330 deg-No Ice <br /> 25 0.9 Dead+1.0 Wind 330 deg-No Ice <br /> 26 1.2 Dead+1.0 ice+1.0 Temp <br /> 27 1.2 Dead+1.0 Wind 0 deg+1.0 Ice+1.0 Temp <br /> 28 1.2 Dead+1.0 Wind 30 deg+1.0 Ice+1.0 Temp <br /> 29 1.2 Dead+1.0 Wind 60 deg+1.0 Ice+1.0 Temp <br /> 30 1.2 Dead+1.0 Wind 90 deg+1.0 Ice+1.0 Temp <br /> 31 1.2 Dead+1.0 Wind 120 deg+1.0 Ice+1.0 Temp <br /> 32 1.2 Dead+1.0 Wind 150 deg+1.0 Ice+1.0 Temp <br /> 33 1.2 Dead+1.0 Wind 180 deg+1.0 Ice+1.0 Temp <br /> 34 1.2 Dead+1.0 Wind 210 deg+1.0 Ice+1.0 Temp <br /> 35 1.2 Dead+1.0 Wind 240 deg+1.0 Ice+1.0 Temp <br /> 36 1.2 Dead+1.0 Wind 270 deg+1.0 Ice+1-0 Temp <br /> 37 1,2 Dead+1.0 Wind 300 deg+1.0 Ice+1.0 Temp <br /> 38 1.2 Dead+1.0 Wind 330 deg+1.0 Ice+1.0 Temp <br /> 39 Dead+Wind 0 deg-Service <br /> 40 Dead+Wind 30 deg-Service <br /> 41 Dead+Wind 60 deg-Service <br /> 42 Dead+Wind 90 deg-Service <br /> 43 Dead+Wind 120 deg-Service <br /> 44 Dead+Wind 150 deg-Service <br /> 45 Dead+Wind 180 deg-Service <br /> tnxTower Report-version 8.1.1.0 <br />