Laserfiche WebLink
victaulic.com <br /> 2.0 CERTIFICATION/LISTINGS <br /> c L us FMVdS ( E UK <br /> C A <br /> N1Y LISTED APPROVED O oLpcB <br /> EN 10311 BS EN 10311 <br /> CPR(EU) CPR(UK) <br /> No.305/2011 2019 No.465 <br /> NOTES <br /> • When supplied as"hot dip galvanized"the following fittings are UL Classified in accordance with ANSI/NSF 61 and for use on cold+86°F/+30°C potable water <br /> service and ANSI/NSF 372:No. 10 90'Elbow,No. 11 45'Elbow,No. 12 22 V?Elbow,No. 13 111/4'Elbow,No.100 90'Long Radius Elbow,No. 110 45°Long <br /> Radius Elbow,No.20 Tee,No.25 Tee with Grooved Branch,No.30 45'Lateral,No.60 Cap,No.50 Concentric Reducers,No.51 Eccentric Reducers. <br /> • The following Victaulic fittings are VdS approved:No.10 90'Elbow,No.11 45'Elbow,No.20 Tee and No.60 Cap. <br /> • The following Victaulic fittings are LPCB approved:No.10 90'Elbow,No.11 45'Elbow,No.12 22 1h Elbow,No.13 11 1/4'Elbow,No.30 45'Lateral,No.30-R <br /> Reducing Lateral,No.100 Long Radius Elbow,No.110 Long Radius Elbow,No.20 Tee,No.35 Cross,No.60 Cap,No.25 Reducing Tee,No.33 True Wye,No.50 <br /> Concentric Reducer,No.51 Eccentric Reducer and No.29M Tee with Threaded Branch. <br /> • The following Victaulic fittings are FM approved:No.10 90°Elbow,No.11 45'Elbow,No.12 221h Elbow,No.13 111/a°Elbow,No.30 45'Lateral,No.100 Long <br /> Radius Elbow,No.20 Tee,No.35 Cross,No.60 Cap,No.25 Reducing Tee and No.50 Concentric Reducer. <br /> • Download publication 10.01 for Fire Protection Certifications/Listings Reference Guide to view which sizes of the fittings listed above have active fire protection <br /> approvals. <br /> 3.0 SPECIFICATIONS - MATERIAL <br /> Fitting: (specify choice) <br /> LJ Standard: Ductile iron conforming to ASTM A536, Grade 65-45-12. <br /> ❑ Optional: Segmentally welded carbon steel, standard wall, conforming to ASTM A53, Type E or S, Gr. B <br /> Nipples: (specify choice) <br /> ❑ 3�4-67DN20- DN150: Carbon steel, Schedule 40, conforming to ASTM A53, Type E or S, Gr. B <br /> ❑ 8- 127DN200- DN300: Carbon steel, standard wall, conforming to ASTM A53, Type E or S, Gr. B <br /> Flanged Adapter Nipples: (specify choice) <br /> ❑ Class 125 Flange: Cast iron conforming to ANSI B16.1 <br /> ❑ Class 150 Flange: Carbon steel conforming to ANSI B16.5, raised or flat face <br /> ❑ Class 300 Flange: Carbon steel conforming to ANSI B16.5, raised or flat face <br /> Fitting Coating: (specify choice) <br /> ❑ Standard: Orange enamel <br /> ❑ Optional: Hot dip galvanized and others. Some fittings supplied electroplated as standard -see product <br /> specifications <br /> Flanged Adapter Nipple Coating: (specify choice) <br /> ❑ Standard: None (Unfinished) <br /> ❑ Optional: Orange enamel, hot dip galvanized and others <br /> 07.01 1449 Rev AJ Updated 05/2023 ©2023 Victaulic Company.All rights reserved. <br /> victaulic.com 2 ✓ctsulicr <br />