Laserfiche WebLink
CO® Worldwide www.tyco-fire.com <br /> Contacts <br /> Series ELO.231 FRB - 11.2 K-factor <br /> Upright and Pendent Sprinklers <br /> Quick Response, Standard Coverage <br /> IMPORTANT The 11.2K ELO-231FRB Upright and <br /> to Technical Data Sheet Pendent Sprinklers were subjected to <br /> Refer <br /> Refer 0 for warnings pertaining to full scale, high-piled storage fire tests <br /> 9 p 9 to qualify their use in lieu of 5.6 or <br /> regulatory and health information. 8.0 K-factor standard spray sprinklers <br /> Always refer to Technical Data for the protection of high-piled storage. <br /> Sheet TFP700 for the "INSTALLER Higher flow rates can be achieved at <br /> WARNING" that provides cautions much lower pressures with the 11.2K <br /> with respect to handling and instal- ELO-231 FRB Sprinklers, making <br /> lation of sprinkler systems and com- their use highly advantageous in high '4 <br /> ponents. Improper handling and density applications, such as the pro- - <br /> installation can permanently damage tection of high-piled storage. <br /> a sprinkler system or its compo- <br /> nents and cause the sprinkler to fail pp• <br /> to operate in a fire situation or cause intermediate level version of the -_ <br /> Sprinklers can Series ELO-231FRB S - <br /> it to operate prematurely. p <br /> be obtained by utilizing the Series <br /> ELO-231FRB Upright Sprinkler with <br /> Scan the QR code or enter the URL the WSG-2 Guard & Shield, and a <br /> in a web browser to access the most pendent intermediate level version <br /> up-to-date electronic version of this of the Series ELO-231 FRB Sprinklers <br /> document. Data rates may apply. can be obtained by utilizing the Series <br /> _i ELO-231FRB Pendent Sprinkler with <br /> the WS-2 Shield. If there is a possibil- <br /> ity of the pendent intermediate level <br /> version being exposed to mechanical <br /> damage, a G-2 Guard can be added. <br /> ` The Series ELO-231FRB Sprinklers ✓ ' . <br /> described herein must be installed \ ✓ <br /> '; and maintained in compliance with this �� r <br /> document, as well as with the applica- <br /> We standards of the National Fire Pro- <br /> L tection Association(NFPA), in addition Sprinkler <br /> docs.jci.com/tycofire/series- to the standards of any other authori- <br /> elo-231frb-11_2-k-up-pen-res-cov ties having jurisdiction.Failure to do so <br /> may impair the performance of these Identification <br /> devices. Numbers (SINs) <br /> General The owner is responsible for main- <br /> taining their fire protection system Refer to Table A for sprinkler identifica- <br /> Description and devices in proper operating con- tion numbers. <br /> dition. Contact the installing contrac- <br /> TYCO Series ELO-231 FRB 11.2K Quick for or product manufacturer with any <br /> Response,Standard Coverage,Upright questions. <br /> and Pendent Sprinklers (Ref. Figure 1) Installation of Series ELO-231FRB <br /> are automatic sprinklers of the frangi- Pendent Sprinklers in recessed <br /> ble bulb type.They are quick response escutcheons will void all sprinkler war- <br /> spray sprinklers that produce a hemi- ranties, as well as possibly void the <br /> spherical water distribution pattern sprinkler's Approvals and/or Listings. <br /> below the deflector. <br /> NFPA 13 prohibits the installation of <br /> 112 in. NPT sprinklers with a K-factor <br /> greater than 5.6K in new installations. <br /> They are intended for use in retrofit <br /> applications only. <br /> Page 1 of 4 APRIL 2022 TFP344 <br />