Laserfiche WebLink
TFP172 <br /> Page 3of4 <br /> Care and 2-7/8" DIA. _ <br /> Maintenance (73,0 mm) <br /> 2-1/4" DIA. <br /> The TYCO Series TY-FRB,5.6 K-factor, E OF (57,2 mm) <br /> Upright (TY313) and Pendent (TY323) SPRI ER <br /> Sprinklers must be maintained and ser- FITTING 5/8"(15,9 mm) <br /> viced in accordance with this section. FLUSH <br /> Before closing a fire protection system 3/8 5/16" <br /> main control valve for maintenance (9,5 7,9 mm) 7 Ll <br /> work on the fire protection system <br /> that it controls, obtain permission to 1/8" f <br /> shut down the affected fire protection MOUNTING 2 mm I <br /> systems from the proper authorities SURFACE ) <br /> and notify all personnel who may be CLOSURE SERIES MOUNTING /8" (34,9 mm) <br /> affected by this action. TY-FRB PLATE <br /> Absence of the outer piece of an 3/4' 1 mm) <br /> escutcheon, which is used to cover FIGURE <br /> a clearance hole, can delay sprinkler SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY 323) <br /> operation in a fire situation. WITH TWO PIECE 518 INCH TOTAL ADJUSTMENT STYLE 15 <br /> The owner must assure that the sprin- <br /> RECESSED ESCUTCHEON <br /> klers are not used for hanging any <br /> objects and that the sprinklers are only 2-7/8" DIA. _ <br /> cleaned by means of gently dusting (73,0 mm) <br /> with a feather duster; otherwise, non- FACE OF <br /> operation in the event of a fire or inad- SPRINKLER 2-1/4" DIA. <br /> vertent operation may result. FITTING (57,2 mm) <br /> Sprinklers which are found to be 5/16 1/4" <br /> leaking or exhibiting visible signs of (7,9 6,4 mm) 1/2"(12,7 mm) <br /> corrosion must be replaced. FLUSH <br /> Automatic sprinklers must never be 1 <br /> painted, plated, coated, or other ri <br /> - <br /> 711 <br /> wise altered after leaving the factory. " <br /> 1/8 <br /> Modified sprinklers must be replaced. MOUNTING (3,2 <br /> Sprinklers that have been exposed to SURFACE <br /> corrosive products of combustion, but <br /> have not operated,should be replaced <br /> if they cannot be completely cleaned CLOSURE SERIES MOUNTING 1-1 (34,9 mm) <br /> by wiping the sprinkler with a cloth or TY-FRB PLATE 7/8"(22,2 mm) <br /> by brushing it with a soft bristle brush. FIGURE 5 <br /> Care must be exercised to avoid SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) <br /> damage to the sprinklers before, WITH TWO PIECE 112 INCH TOTAL ADJUSTMENT STYLE 20 <br /> during, and after installation. Sprin- RECESSED ESCUTCHEON <br /> klers damaged by dropping, striking, <br /> wrench twist/slippage,or the like, must Limited Recessed Escutcheon <br /> be replaced. Also, replace any sp.... Specify: Style 15 Recessed Escutch- <br /> kler that has a cracked bulb or that has Warrant eon with(specify")finish, P/N(specify") <br /> lost liquid from its bulb. (Ref. Installa- Y <br /> tion Section.) Specify: Style 20 Recessed Escutch- <br /> For warranty terms and conditions,visit eon with(specify')finish, P/N(specify") <br /> The owner is responsible for the www.tyco-fire.com. Refer to Technical Data Sheet TFP770 <br /> inspection,testing,and maintenance of <br /> their fire protection system and devices Ordering <br /> Sprinkler Wrench <br /> in compliance with this document, as Specify: W-Type 6 Sprinkler Wrench, <br /> well as with the applicable standards procedure P/N 56-000-6-387 <br /> of the National Fire Protection Asso- Specify: W-Type 7 Sprinkler Wrench, <br /> ciation (e.g., NFPA 25), in addition to Contact your local distributor for avail- P/N 56-850-4-001 <br /> the standards of any other authorities ability.When placing an order, indicate <br /> having jurisdiction.Contact the install- the full product name and Part Number <br /> ing contractor or product manufacturer (P/N). <br /> with any questions. <br /> Sprinkler Assemblies with NPT <br /> Automatic sprinkler systems are rec- Thread Connections <br /> ommended to be inspected, tested, Specify: Series TY-FRB Upright or <br /> and maintained by a qualified Inspec- Pendent (specify) Sprinkler, SIN <br /> tion Service in accordance with local (specify), K=5.6, Quick Response, <br /> requirements and/or national codes. (specify) temperature rating, (specify) <br /> finish, P/N (specify, refer to Table A). <br />