Laserfiche WebLink
Engineered <br /> ECS EJECTOR <br /> ECS' corrosion <br /> Solutions, <br /> Complete Corrosion Control. <br /> IX <br /> ECS Ejector Automatic Air Vent - PAV-W ,' 0 <br /> Specifications <br /> ■ <br /> Stock Number: PAV-W <br /> PAV-WS ( upervised) <br /> Service Pressure: Up to 175 PSIG (12 Bar) <br /> . System Connection: 1" NPT Male <br /> Temperature Range: 40°F to 120°F (4.5°C to 49°C) <br /> v Dimensions: 14"(L) X 7"(D) X 7"(H) <br /> (368mm(W) X 191mm(D) X 203mm(H)) <br /> FM weight: 8 Lbs (3.6 Kg) <br /> Clear Height: 5" (127mm) <br /> APPROVED <br /> • Patented redundant float design eliminates piping to a drain <br /> U.S. Pat. No. 8,636,023 Support Hanger Not Required <br /> General Description <br /> The ECS Ejector Automatic Air Vent (PAV-W/WS) is a external corrosion. The float mechanism on the ECS <br /> device that provides automatic venting of trapped air in Ejector Automatic Air <br /> wet pipe fire sprinkler systems. As a fire sprinkler system Vent will automatically close when water reaches the <br /> is filled with water,trapped air migrates to the high point vent and the redundant design eliminates the need to <br /> of the system near the vent installation location which plumb the PAV-W/WS to drain. If the primary air vent <br /> allows for trapped air to be vented. Trapped air contains valve allows any significant amount of water to leak past <br /> oxygen which is the primary cause of corrosion in fire the second air vent valve will close preventing water <br /> sprinkler systems. Corrosion in wet pipe fire sprinkler from discharging and provide a system pressure reading <br /> systems is directly proportional to the amount of oxygen on the pressure gauge. This condition will be an indica- <br /> trapped within the system piping, so a reduction in lion that the primary automatic gas vent valve has failed <br /> trapped air will in turn reduce the internal corrosion and requires service or replacement. The pressure gauge is <br /> activity of the fire sprinkler system. Venting the trapped designed to be visible from the floor below the ECS <br /> air in a wet pipe sprinkler system can also decrease Ejector Automatic Air Vent from a distance of <br /> water delivery time and reduce false water flow alarms. approximately 30 feet. <br /> The ECS Ejector Automatic Air Vent must be installed as There are two available models of the ECS Ejector <br /> shown on the engineering design documents, if a Automatic Air Vent: PAV-W and PAV-WS. The units both <br /> location is not provided install the vent at an accessible operate as described previously, but the PAV-WS includes <br /> high point on the fire sprinkler system remote from the a wiring connection to a monitoring circuit. A single <br /> system riser where gas can be vented and at a location contact rated 24VAC/DC @ 2A for electronic monitoring <br /> that the pressure gauge provided for visual monitoring with an end of line resistor (EOLR) must be installed <br /> can be viewed from directly below. The PAV-W/WS is according to the wiring diagram in Figure 1 to <br /> also equipped with brass components that allows the electronically monitor the PAV-WS. <br /> device to be installed in areas subject to <br /> Engineered Corrosion Solutions•11336 Lackland Road•St.Louis,MO 63146•Phone 1-314-432-1377• www.ecscorrosion.com <br /> ECS EJECTOR AUTOMATIC AIR VENT - PAV-W/WS May 2018-Rev 4 <br /> 1 <br />