My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1605 SE EVERETT MALL WAY WALMART 2025-09-10
>
Address Records
>
SE EVERETT MALL WAY
>
1605
>
WALMART
>
1605 SE EVERETT MALL WAY WALMART 2025-09-10
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/10/2025 2:48:40 PM
Creation date
8/21/2025 12:35:01 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1605
Tenant Name
WALMART
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
273
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Engineered <br /> ECS EJECTOR <br /> ECS" corrosion Automatic Air Vent <br /> Solutions," designed for fire sprinkler systems <br /> Complete Corrosion Control. <br /> FIGURE 1-Wiring Diagram Figure 2- ECS Ejector Automatic Air Vent Outline Drawing <br /> INSTALLATION NOTES: <br /> 1. If Monitored By The Building Fire <br /> Alarm System, Provide One Ad- <br /> dressable Monitoring Module To <br /> Monitor The Ejector Automatic Gas Discharge Orifice <br /> Air Vent. <br /> 2. Connect The Ejector Automatic 1"Connection to 5"(127mm) <br /> Air Vent To The Addressable S Sprinkler System r, <br /> Monitoring Module. <br /> N � <br /> 3.Supervise The Circuit Using An <br /> End-Of-Line (E.O.L.) Resistor In Primary and Secondary D <br /> Gas Vent Valves o <br /> 9 <br /> m - <br /> ECS � <br /> Automatic 0 Q <br /> pir Vent � <br /> J � <br /> 0 <br /> C <br /> \Wring Ha mess Su fled-h <br /> Eo.L. A,V-1 %"Isolation Ball Valve 2"(51mm) <br /> Pressure Gauge <br /> Addressable "Y"Strainer with <br /> �—Moni or Motlule <br /> Fr—Panell N-11 os ,�Ne Ball Valve <br /> Addressable Device ' <br /> Figure 3- ECS Ejector Automatic Air Vent Installed on Sprinkler System <br /> 1"Connection to Sprinkler System must <br /> be on to or side of pipe <br /> NOTE: Patented redundant float design <br /> eliminates piping vent to drain. <br /> NOTE: Piping to the vent assembly cannot be <br /> installed in a configuration that would trap water <br /> and prevent drainage to the sprinkler system; a <br /> water trap impedes the ability of the vent to <br /> remove gas from the fire sprinkler system. <br /> Engineered Corrosion Solutions- 11336 Lackland Road-St. Louis, MO 63146-Phone 1-314-432-1377- www.ecscorrosion.com <br /> ECS EJECTOR AUTOMATIC AIR VENT - PAV-W/WS May 2018-Rev 4 <br /> 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.