Laserfiche WebLink
Store/Cusl: Wal-Mart 90 Ipac Supercenter#3053 OEM Hill PHOENIX EMS Manufacturer Novar <br /> Location: Everett,Washington Phone# 800-685-5475 Rack EMS Model# OPUS XCM.20R <br /> MTC Quote/Job: 80054 Prepared By: johnmcc <br /> Model No: PS86VMRAD Preto Size: 90 RIB Prato 7126113 Date 11/5/2013 <br /> Equipment Type: InviroPac C <br /> Field Connection: Rear vertical up Rack Voltage: 460/60/3 <br /> Rev. Date By: Deription Control Control Voltage Transformer <br /> sc <br /> Power Rack 460/60/3 208/60/1 (KVA) <br /> 1 2/6/2023 TW Changes Per FOR Updates. 208/60/1 N/A <br /> MCA 111.4 5.0 <br /> MOPD 125 10 <br /> Refrigerant Type: R-407A <br /> Condenser Model# BNL-D06-AO48-4-WN -BG <br /> Fan RPM 830 Coaled(Y/N) Y Discharge Heat Reclaim Liquid Receiver Subcooler ' <br /> T.D. 12.6` Fin Spacing(FPI) 10 Manifold Size 2-1/8" Water/Air N/A Line size from receiver 1-1/8" Orientation Horizontal Heat Exchgr Model B10THx30 w : w ^^-� <br /> FLA 19.8 Disch.Regulator WA Desuperheating or Full Contl N/A Manifold 2-118" Dia.x Length H12x108 S.G.1 Subcooler Load(MBH) 24.1 rc LLpp3e�ow°u <br /> Main Condenser Supply Heal Exchanger Model# Lbs. 80%Pum down rc o <br /> MOPD 25 PPY 2-1/8" 9 N/A Drier DCR-969 @ P 376 S.G.2 Subcooler Load(MBH) 0 O aroma :app�"+-a> <br /> Weight(Ibs) 2140 Heat Reclaim Valve N/A Sigh(glass SA-19g Condenser Flooding Charge 43 Total Subcooler Load(MBH) 24.1 z ::_a,°�'a°:rc:LL p<s <br /> VFD 177U5415 Oil System GPM N/A Main Cord.Return 2-1/8" Rack&Cond.Ref.Charge 317 Sat Suct Temp(°F) 60 O u��_�rc w �"� € <br /> Split 50% 50% N/A Discharge Oil Separator OS6-21-RES Isol.Valve To N/A Drain Regulator A81-1 1/8PX2 1/8C AID Receiver Pressurization A9-5/8PX5/8C B Subcooler Controller Model Sporlan g a;o=°01 o�o'u' <br /> Solenoid (1)OE42S2130 (1)OE42S2130 N/A Oil Reservoir N/A Isol.Valve From N/A Liquid Pressure Regulator A810E-1 1/8PX1 1/8C A/D Surge Solenoid N/A Expansion Valve#1 SER-B <br /> Oil Brand Type LPR bypass Solenoid Max Operating Pressure Expansion Valve#2 F <br /> Isol.Valve To 1-5/8" 1-5/8" N/A YP Emkarale RL 2-3MAF YP OE25S290 P 9 450# P N/A <br /> Isol.Valve From 1-3/8" 13/8" N/A Oil Differential Valve N/A Liquid Solenoid Valve#1 E6S140 <br /> Liquid Solenoid Valve#2 WA <br /> Suction Group 1 Design Requirements Suction Group 1 System Capabilities System Piping Connections Liquid Suction Defrost Subcooler EPR Valve PORT57 <br /> Total Load Required 357.1 Net Refrig Effect Available(MBH) 388.6 Loop 1C 1-518" 3-1/8" None Isol.Valve To 112" <br /> Condensing Temp.(°F) 103 %Net Refrig Effect Avail 108.8% Spare 718" 1-5/8'. None Isol.Valve From 7/8" <br /> Design Ambient Temp(°F) 88 Total Heal of Rejection(MBH) 552.6 N/A N/A N/A N/A <br /> Saturated Suction Temp(°F) 18 Suction Manifold Size 2-5/8" N/A N/A N/A N/A <br /> Return Gas Temp('F) 50 Suction Filter 5 FA-42S(1) N/A N/A N/A N/A ■` w�.m a <br /> 2o <br /> Subcooled Liquid Temp(°F) 75 Suction Accumulator A10-31 N/A N/A N/A N/A F A[7�`e <br /> Superheat for NRE(°F) 10°F N/A N/A N/A N/A z¢ I <br /> 2ma� <br /> Compressor Suction Group 1 Net Refrig. Condenser Heat of Variable VFD Model No. Min.Var. Max.Var. Unloader Unloader% HP RPM RLA LRA z I. <br /> d <br /> Position Compressor Model Effect(MBH) %of Load Rejection(MBH) Capacity? Capacity Capacity O <br /> U <br /> 1 ZFD18KVE-TFD-261 49.1 13.7% 70.3 Unloader N/A 4.91 49.1 D 10,100 6 3500 11.1 70 <br /> 2 ZF18KVE-TFD-262 48.5 13.61/6 68.9 No N/A N/A N/A 0 100 6 3500 11.1 70 <br /> 3 ZF18KVE-TFD-262 48.5 13.6% 68.9 No N/A N/A N/A 0 100 6 3500 11.1 70 <br /> 4 ZF18KVE-TFD-262 48.5 13.6% 68.9 No N/A N/A N/A 0 100 6 3500 11.1 70 <br /> 5 ZF18KVE-TFD-262 48.5 13.6% 68.9 No N/A N/A N/A 0 100 6 3500 11.1 70 <br /> 6 ZF18KVE-TFD-262 48.5 13.6% 68.9 No N/A N/A N/A 0 100 6 3500 11.1 70 Z <br /> 7 ZF18KVE-TFD-262 48.5 13.6% 68.9 No N/A N/A N/A 0 100 6 3500 11.1 70 O C� <br /> 8 ZF18KVE-TFD-262 48.5 13.6% 68.9 No N/A N/A N/A 0 100 6 3500 11.1 70 <br /> Compressor Staging Comps.on %of Required Load O O Q <br /> From To Notes: `Condenser T.D.derated by 8% cp ?� <br /> Stop 1 1.4% 13.6% LID Z J <br /> J O <br /> Step 2 1&2 14.89/6 27.1% <br /> Step 1,2&3 28.2% 40.5% <br /> M <br /> Step 4 1,2,3,&4 41.7% 53.9% Q ran <br /> Step 5 1,2,3,4&5 55.1% 67.49/6 > w z > <br /> Step 6 1,2,3,4,5&6 66.6% 80.8% > W w <br /> Step 7 1,2,3,4,5,6&7 82.0% 94.3% m <br /> W O H <br /> Step 8 1,2,3,4,5,6,7&8 95.5% 107.7% 111 w <br /> Step 9 N/A N/A N/A L____J w U) <br /> Step 10 N/A N/A N/A I/1 C"1\ w o <br /> w UU F <br /> w w <br /> z <br /> m <br /> O <br /> CUSTOMER Wal-Mart ISSUE BLOCK <br /> STORE: #3053 CONTACT <br /> H U S S m A n n R LOCATION: Everett,WA SALESMAN Keith Exler <br /> QUOTE/JOB#: CRM178324 ENGINEER Tabitha Waldron <br /> C REFRIGERATOR/UNIT COOLER DIS REOM UNIT SIZES DESIGN CONDITIONS CONDENSING UN IT DATA <br /> O SYS AIR CAP EVP DEF DEF WEIGHT SPEC MID POINT COND REF CONDENSING UNIT CAP COMP MID POINT UNIT UNIT UNIT <br /> N <br /> D # SIZE MODEL DESCRIPTION TMP (MBH) TMP TYPE TER LBS SHEET SST DEG TYPE MODEL# MBH kW CONDT VOLT MCA MOPD <br /> RCU1 13.11.10 KRD44E-148TDAK Pickup Freezer W.1. -8 11.30 -16 EL 226 40.6Lx17.3Wx33H -19 90.4 Ambient R-448A XFAL-030Z-TFC-081 12.6 20813PH 17.1 25 <br /> 2.4A 208/l/60 Fan Motor <br /> 17AA 208/3/60 Eleetrio defrost <br /> KE2 SHI LOOSE INCLUDES: <br /> 1 E5 Valve CASE FANS,LIGHTS,CONDENSATE PAN HTR AND PUMP, <br /> DEFROST HEATER NOT POWERED FROM THE UNIT <br /> RCU2 13xllx10 KRD44E-148TDAK Pickup Freezer W.I. -10 11.30 -18 EL 244 40.6Lxl7.3WX33H -21 90.4 Ambient R-44aA XFAL-035Z-TFC-081 14.3 208/3PH 24.9 40 <br /> 2.4A 208/1/60 Fac Motor <br /> 17AA 208/3/60 Electric defrost <br /> CHECKED BY: DL <br /> KE2 SHIP LOOSE INCLUDES: <br /> 1 ES Valve DRAWN BY: GM <br /> CASE FANS,LIGHTS,CONDENSATE PAN HTR AND PUMP, <br /> DEFROST HEATER NOT POWERED FROM THE UNIT <br /> PROTO: 90 <br /> PROTO CYCLE: 11/11/22 <br /> RCU3 17xl3x10 GLD66D-268TDAA Pickup Cooler W.I. 34 20.90 26 EL 226 40.6Lxl7.3Wx33H 24 90.4 Ambient R-448A XFAM-025Z-TFC-081 21.6 208/3PH 18.1 30 DOCUMENT DATE: 02/22/23 <br /> 3.OA 208/1/60 Fan Motor <br /> 20.9A 208/l/60 Eleemie defrost <br /> KE2 SHIP LOOSE INCLUDES: <br /> E6 Valve <br /> CASE FANS,LIGHTS,CONDENSATE PAN HTR AND PUMP, <br /> DEFROST HEATER NOT POWERED FROM THE UNIT <br /> "CARP COMPLIANCE IS FOR RESPONSIBILITY" <br /> DOCUMENTS THAT DO NOT <br /> HAVE THE ARCHITECT OR <br /> ENGINEER OF RECORD <br /> SEAL AND SIGNATURE <br /> SHALL BE CONSIDERED <br /> NOT FOR CONSTRUCTION <br /> REFRIGERATION <br /> SUBMITTALS <br /> EXISTING CONDITIONS WERE TAKEN FROM EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING <br /> ORIGINAL DRAWINGS AND MAY NOT REFLECT A THOROUGH KNOWLEDGE OF ALL DRAWINGS AND <br /> EXACT"AS-BUILT'CONDITIONS.CONTRACTOR SPECIFICATIONS IN THEIR RELATED FIELD.THE FAILURE <br /> SHALL FIELD VERIFY ALL EXISTING CONDITIONS TO ACQUAINT THEMSELF WITH THIS KNOWLEDGE DOES <br /> PRIOR TO SUBMITTING FINAL BIDS.CONTRACTOR NOT RELIEVE THE RESPONSIBILITY OF PERFORMING <br /> SHALL CAREFULLY COORDINATE NEW WORK AND THE WORK PROPERLY.NO ADDITIONAL SHEET: <br /> DEMOLITION WITH ALL OTHER DISCIPLINES AND COMPENSATION SHALL BE ALLOWED BECAUSE OF R4 <br /> EXISTING CONDITIONS. CONDITIONS THAT OCCUR DUE TO FAILURE TO <br /> FAMILIARIZE WORKERS WITH THIS KNOWLEDGE. <br />