Laserfiche WebLink
? , r SHEET NOTES <br /> t ' DEMOLITION NOTES COLOR LEGEND <br /> ' 4 + 1. NOT USED. P# COLOR NAME 1. PATCH AND REPAIR EXTERIOR WALL SURFACES, <br /> 2. REMOVAL OF BUILDING MOUNTED ITEMS,SHOWN OR DAMAGED OR EXPOSED DUE TO REMOVAL OF BUILDING <br /> NOTED TO BE DEMOLISHED OR AS REQUIRED BY SCOPE MOUNTED ITEMS,TO MATCH ADJACENT AS REQUIRED. <br /> l� OF WORK,SHALL OCCUR PRIOR TO PAINTING BUILDING. 2. REFER TO DETAILS ON SHEET A2.1 FOR SUBSTRATE AND b2 <br /> COORDINATE DEMOLITION WORK SO EXTERIOR P5E SAFETY YELLOW OSHA STANDARD FINISH REQUIREMENTS AT LOCATIONS OF BUILDING Pgineering <br /> hitecture <br /> PAINTING WILL OCCUR PRIOR TO INSTALLATION OF MOUNTED SIGNS. <br /> ;. -- - BUILDING MOUNTED ITEMS. 3. RESURFACE EXISTING EIFS WHERE SHOWN(HATCHED <br /> r P33E CREAM AREA). <br /> 4. NOT USED. 2809 Ajax Avenue Suite 100 <br /> 5. PRIOR TO PAINTING WALL AT LOCATION(S)OF LIT ID/LOGO Rogers Arkansas 72758 <br /> T��Z • Phone 479636.3545 <br /> w SIGN(S),COORDINATE SCOPE OF WORK WITH WALMART <br /> P36E BLACK CM Fax'4796361209 <br /> 6. IF PAINTING ADJACENT WALLS PAINT FRAMES,AND Architect of Record <br /> T-a " Additional Permits Are Required ` City of Everett Permit Review DOWNSPOUTS,EXPOSED METAL FLASHING,HANDRAILS, William Douglas Hurley <br /> a i1, �. .., P49E DARK GRAY AND EXPOSED MISCELLANEOUS STEEL TO MATCH Washington Lcense No 8855 <br /> 1 - as r�• - - '�3 y,,� For This Project To Include: EVERETT Status:Reviewed for Permit PRIMARY ADJACENT BUILDING COLOR UNO. Unified Business ID No.602 491 668 <br /> 08/15/2023 1:24:55 PM 7. PAINT ANY ROOFTOP GAS PIPING P5E .WHERE <br /> ❑Plumbing P76U WALMART BLUE(URETHANE-LIKE) EXTERIOR WALL IS BEING PAINTED,GAS PIPE ALONG SIDE <br /> �3••s PICKUP - f Sprinkler <br /> I 'T ❑ P WALL TO GRADE SHALL MATCH ADJACENT BUILDING.DO w w >y� o <br /> q - n• Imo, t °'r faa- ❑Mechanical NOT PAINT METER OR VALVES. ° o.> <br /> OUTDOOR •w ❑ Fire Alarm 8. IF PAINTING ADJACENT WALLS PAINT CANOPY y r "O <br /> j ,i ❑x Electrical P134E LIGHT GRAY STRUCTURAL STEEL AND FLASHING TO MATCH ADJACENT �'iw "w35o <br /> WALL,UNO. <br /> P135E MEDIUM GRAY 9. WHERE CANOPIES ARE VISIBLE TO AND ACCESSED BY wwz3tagp�w<°pm <br /> •r '+ - - - CUSTOMERS,PAINT UNDERSIDE OF CANOPY DECK P33E <br /> d ! DO NOT PAINT CANOPY DECK IF NOT PREVIOUSLY <br /> PAINTED <br /> SITE ID P162E BLACK GRAY 10.INSTALL GRAY BOLLARD SLEEVES AT ALL ENTRANCE 3H3oo°hoy<uw <br /> BOLLARDS.PAINT ALL SAFETY BOLLARDS P5E.PAINT ALL <br /> ••• OTHER PAINTED/DECORATIVE BOLLARDS P135E. <br /> SITE PLAN SITE ID 11.PAINT SECURITY WALL PACK HOUSINGS TO MATCH <br /> ADJACENT WALL.REMOVE PAINT OVERSPRAY FROM <br /> Ref 6-A2 12.DO NOT PAINT LED WALL PACK HOUSINGS <br /> 13.PAINT GARDEN CENTER STEEL DOORS AND FRAMES <br /> P36E. <br /> 14.NOT USED. <br /> 15.DO NOT PAINT QUIK BRIK,STONE VENEER,FACE BRICK, <br /> UNPAINTED TILT-WALL OR PRECAST PANELS <br /> 16.AT MASONRY LOCATIONS WHERE SIGNS ARE BEING <br /> REPLACED,REMOVE AND PAINT AREA BEHIND SIGN TO <br /> MATCH EXISTING COLOR.REF SPEC 09900. <br /> 17.PAINT JIB CRANE P36E ON JIB BOOM.P5E ON HANDRAILS. <br /> WHITE LETTERS LIKE-FOR-LIKE FACE, YELLOW SPARK, O O <br /> COLOR PMS 285C F.COLOR PMS 1235C <br /> SHERWIN-WILLIAMS CUSTOM BLUE CAP CAP L <br /> BRONZE/ORDER NUMBER REVEAL DURADONIC DOOR P134E P134E P134E O C r <br /> 7248-0044642 BRONZE,REF TABLE HOOD CAP CAP <br /> -BRONZE MATCH FOR CUSTOM COLORwaiiWalmart P76U O 0 Q <br /> -CUSTOM MANUAL MATCH P134E P134E P134E P134E P134E <br /> BAC COLORANT: OZ 32 64 128 CAP P135 P135E TZ <br /> W 1 WHITE - 43 - 1 P134E ♦♦♦y///��� a s <br /> Bi BLACK 6 4 1 1 vJ <br /> R2 MAROON - 19 - 1 PRECAST CONCRETE CAP ��fl <br /> Y3 DEEP GOLD - 48 1 1 JJ O vo <br /> W <br /> G2 NEW GREEN - 18 - - z w N <br /> ONE GALLON I j O <br /> #1354T00104 REPLACE FACE ON EXISTING SIGN P135E P134E P134E P134E P134E W m <br /> UI TRADECP 9796999993 CABINET,TYP OF BOTH SIDES P134E P135E DOOR P135E P135E 0 to <br /> TVP a <br /> W � <br /> MULTI-TENANT MONUMENT SIGN LEFT ELEVATION Ww <br /> w <br /> 0 <br /> ISSUE BLOCK <br /> CAP CAP CAP <br /> CAP CAP CAP fir134E P1 P134E P134E 34E P5E <br /> P134E P134E P134E 1 <br /> 134E P,34E <br /> CAP <br /> P134E <br /> I I <br /> P134E P134E P134E P134E P134E P134E P134E <br /> FENCING SHOWN DASHED P134E P134E P134E P134E P134E P134E P134E <br /> FOR CLARITY DOOR DOOR CHECKED BY: SIB <br /> DRAWN BY: OS <br /> BALE & PALLET ELEVATION REAR ELEVATION PROTO: 90 <br /> 1"=20'-0" a) 1"=20'-0" A B C D E F G PROTO CYCLE: 11.11.2022 <br /> Q Q Q Q Q Q Q DOCUMENTDATE: 02.22.2023 <br /> CAP EQ EQ <br /> CAP P49E P134E 2,0" DOOR DOOR <br /> P134 E CAP w CAP CAP CAP CAP HOOD HOOD <br /> P76U <br /> P134E P134E P134E P134E <br /> )*A;P135E P135E NEW Ow <br /> v <br /> P135E P135E P134E P134E P134 E PP113344EE P134E <br /> P135EE <br /> P135E P76U P134E 1SIGN <br /> REF -A2.1 <br /> 3 4E <br /> GARDEN CENTER FENCING ON FABRICATED <br /> SHOWN DASHED FOR CLARITY PANEL ASSEMBLY <br /> REF 8-A2.1 <br /> RIGHT ELEVATION RBGISTBRED <br /> MCWTECT <br /> W <br /> 03.03.2023 E <br /> °I DOCUMENTS THAT DO NOT <br /> =I HITECTOR <br /> ENGNEER OF RECORDSEAL <br /> a AND SIGNATURE SHALL BE <br /> EQ 6 <br /> 20'-0" L 59'4" <br /> 20'0" CONSIDERED NOT FOR <br /> EQ EQ CAP CONSTRUCTION <br /> EQ EQ EQ EQ EQ EQ <br /> o P49E P134E P134E P49E <br /> O1I CAP NEW SIGN CAP <br /> P134E P134E P134E P134E REF S-A2.1 p135E P135E P76U P134E P135E Ow CAP NEW SIGN CAP <br /> z - - P135E P134E P134E P134E P134E REF2-A2.1 P76U O P734E P134E EXTERIOR <br /> P <br /> - a d <br /> ELEVATIONS <br /> E 7 <br /> 79 <br /> P135E-� P134E P135E P135E P735E P134E NEW SIGN, P135E NEW SIGN P735E P735E P135E P135E NEW SIGN P49E P134E P49E P135E P134E P135E P135E P135E P135E NEW SIGN, P135E P135E P135E <br /> IN EXISTING REF 3-A2.1 REF 1-A2.1 CENTERED <br /> TYP TYP DOOR TYP DOOR DOOR TYP <br /> LOCATION ON FABRICATED IN FIELD <br /> E REF 6-A2.1 PANEL ASSEMBLY GARDEN CENTER FENCING REF 4-A2.1 <br /> JFRONT ELEVATION REF 6-A2.1 SHOWN DASHED FOR CLARITY. SHEET <br />