My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1605 SE EVERETT MALL WAY WALMART 2025-09-10
>
Address Records
>
SE EVERETT MALL WAY
>
1605
>
WALMART
>
1605 SE EVERETT MALL WAY WALMART 2025-09-10
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/10/2025 2:48:40 PM
Creation date
8/21/2025 12:35:01 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1605
Tenant Name
WALMART
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
273
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SCOPE OF WORK <br /> r--------------------------- <br /> I I D9412GV4 BATTERY CALCULATIONS <br /> BDA EQUIPMENT I Total <br /> SYSTEM 2 I Standby Total Standby Alarm Alarm <br /> PT PT PT ;S% <br /> PTDescription Device Quantity Current Current Current Current <br /> eATTERY ControlPanel D9412GV4 1 02000 0.2000 0.3000 03000 <br /> CHARGERAC POWER LOW R ANTENNA BatteryLead Supervision Module D113 1 0.0450 0.0450 0.0450 0.0450 <br /> FAILURE LOSS BATTERY FAILURE MALFUNCTION I <br /> Dual Class AB NAC Module D 192G 1 0.0350 0.0350 0.1000 0.1000 <br /> I I _P2uaiF1ww,LincR&L.T Y a DAZ2 L____ _J---L Q9 8D_ _Q.Q1 SD__ Q.]ODLL 11QQD <br /> BOA EQUIPMENT I r CellularConvnnicator B450V+B444V 1 0.0600 0.0600 0.1800 0.1800 <br /> SYSTEM 1 i L J Annunciator/Keypad(FAA) D1256RB/1257R 2 0.0350 0.0700 0.0700 0.1400 <br /> IFITI <br /> IT �R�Tl <br /> �Tl <br /> �RTS <br /> Pr Pr Pr Pr PT PT PT PT PT POPEXModule D8125 2 0.0500 0.1000 0.0500 0.1000 <br /> RTS RTS RTSRTS RTS RTSRTSPOPITS D9127U 90 0.0008 0.0720 0.0008 0.0720 X X XX X X A ERY qC POWER OW gNTENNA 2 2 2 2 2 I CHARGER LOSS BATTERY BOOSTER MALFUNCTION I NEW INTRUSION POPITS D9127 3 0.0005 0.0015 0.0008 0.0024 <br /> FAILURE FAILURE L J <br /> DUCT DETECTOR DUCT DETECTOR DUCT DETECTOR DUCT DETECTOR DUCT DETECTOR DUCT DETECTOR DUCT DETECTOR DUCT DETECTOR DUCT DETECTOR DUCT DETECTOR DUCT DETECTOR I I Auxilary Relay Module D130 2 0.0600 0.1200 <br /> AND#1 AHU#2 RTU#1 RTU#3 RTU#7 RTU#8 RTU#9 RTU#11 RTU#12 RTU#13 RTU#14 L--------------------------J DSI Splitter ICP-SDI-9114 1 0.0300 0.0300 0�2 <br /> Dual fromC Relay(on Alum) D8130 1 0.0070 0.0070 0.0600 0.0600 WR w <br /> 12v-4w Smoke Detector EOLR D273THE 1 0.0150 0.0150 0.0360 0.0360 2 S m Eno, M <br /> PT PT PT PT PT PT PT PT PT PT PT PT PT PT <br /> L H T TOTAL V $6V_w Bw~ <br /> y N <br /> COMPUTATIONS OTALT <br /> STANDBY 0.646 ALARM 1.435TOTALS < <br /> T T T <br /> e <br /> pIII o a <br /> T< a <br /> COOKING HOOD GARDEN GARDEN GARDEN GARDEN GARDEN FIRE PUMP FIRE PUMP FIRE PUMP FIRE PUMP VALVE VALVE VALVE VALVE TOTAL AMPS USED IN STANDBY= 0.646 X 24 HOURS= 16.492 AH run <br /> SUPPRESSION DRY SYSTEM DRY SYSTEM DRY SYSTEM DRY SYSTEM DRY SYSTEM FAILURE TO PHASE LOSS OF MOTOR TAMPER#7 TAMPER#6 TAMPER#5 TAMPER#4 Z <br /> DELI PREP TAMPER#2 TAMPER#1 LOW AIR HIGH AIR WATERFLOW OPERATE REVERSAL PHASE RUNNING TOTAL AMPS USED IN ALARM= 1.436 X 15 MIN= 0.369 AH o <br /> +20%CONTINGENCY 3.170 AH <br /> TOTAL STANDBYBATTERYREQUDtEMENTS= 19.021 AH <br /> FAA D8125 PT PT PT PT PT PT PT PT PT PT E- <br /> O <br /> TOTAL BACKUP BATTERY PROVIDED= 36.000 AH � <br /> z z B z TOTAL BACKUP BATTERYREQUIRED- 19.021 AH O 0 <br /> FACU F.WER TO ABOVE BREAKROOM RESTROOM MANAGER'S CUSTOMER RISER#1 RISER#2 RISER#1 RISER#2 VALVE TOTAL BACKUP BATTERYRESERVED= 16.979 AH <br /> DETECTORS CPU CORRIDOR CORRIDOR OFFICE SERVICE WATERFLOW WATERFLOW TAMPER TAMPER TAMPER#3 0 <br /> CORRIDOR EXISTING:(2)18ah battery to provide 36 amp hours at 12 volts x <br /> AS PER MINER'S REC. <br /> NEW 1 EXISTING �� ( 27 SECURITY {�M <br /> CENTRAL CELL I FACE ZONEX 2 PORTS E� 0..1..4 Ln <br /> STATION --J D9412GV4 <br /> NOTE: O <br /> ALL SECURITY DEVICES,KEYPADS,MOTIONS, <br /> 120V A.C. SIRENS,ETC.ARE POWERED FROM A <br /> SEPARATE POWER SUPPLY NOT THE CPU. <br /> BOSCH D8004 N W O <br /> TRANFORMEft COVERS '.^'� (Y <br /> [HALL BE UTILIZED] D192G p <br /> Io n <br /> POWERED BY A o 0 0 0 � �� O <br /> LOCKED AND DEDICATED f '" <br /> BRANCH CIRCUIT A TO EVAC 0--�--1� <br /> �IKI SEE SHEET EFP2 6 <br /> 0 0 0 0 <br /> 1 <br /> POINT TO BE POINT TYPE AHJ / COMPLIANCE NOTES w <br /> ANNUNCIATED AS FIRE ALARM SUPERVISORY ALARM "PROPRIETARY SYSTEM" <br /> RISER #1 WATERFLOW x ISSUE BLOCK <br /> RISER #2 WATERFLOW X 1. THIS SYSTEM DESIGN IS BASED UPON COMPLIANCE WITH <br /> RISER #3 WATERFLOW x THE NATIONAL, STATE AND LOCAL CODES. THE <br /> RISER #4 WATERFLOW x OCCUPANCY CLASS IS MERCANTILE. <br /> RISER #5 WATERFLOW X <br /> RISER #1 TAMPER x 2. REMOTE ANNUNCIATOR(S) WILL FEATURE POINT I.D. OF ALL <br /> RISER #2 TAMPER X DEVICES/ZONES IN PLAIN ENGLISH DISPLAY. THE CPU <br /> RISER #3 TAMPER X CABINET HAS NO ANNUNCIATOR OR USER INTERFACE <br /> FIRE ALARM SYMBOLS LEGEND RISER #4 TAMPER X CONTROLS, AND IS A CABINET HOUSING (NON-ANALOG <br /> SYMBOL OTY DESCRIPTION MAKE/MODEL RISER #5 TAMPER X ADDRESSABLE) CIRCUITRY ONLY. <br /> PIV TAMPER X <br /> FAGP EXISTING FIRE ALARM CONTROL PANEL BOSCH D9412GV4 BACKFLOW TAMPER X 3. AT LEAST ONE MANUAL STATION WILL BE INSTALLED AND <br /> FACUEXISTING CONTROL ANNUNCIATOR BOSCH D1256RB DRY VALVE SPRINKLER WATERFLOW X LOCATED WHERE REQUIRED BY THE AHJ, PER NFPA 72. <br /> DRY VALVE SPRINKLER TAMPER x UNLESS OTHERWISE SPECIFIED BY THE AHJ, IT WILL BE <br /> FFAq EXISTING ANNUNCIATOR BOSCH D1257RB DRY VALVE SPRINKLER LOW x LOCATED PER THE DRAWING. <br /> EVAC EXISTING FACILITY COMMUNICATIONS WHEELOCK SAFEPATHID4 SP40S DRY VALVE SPRINKLER HIGH X <br /> w/SP4-APs MANUAL PULL STATION x 4. ONE SMOKE DETECTOR WILL BE INSTALLED ABOVE THE CPU <br /> WHEELOCK SAFEPATH®4 SPB-160 SMOKE / HEAT DETECTORS x IN ACCORDANCE WITH NFPA 72. <br /> AMP EXISTING AUDIO BOOSTER W/SP4Z-A/B SPUTTER <br /> DUCT SMOKE DETECTORS x COOKING HOOD SUPPRESSION SYSTEM x 5. AIR HANDLING UNITS IN EXCESS OF 2000 CFM WHICH CHECKED BY: RH <br /> WHEELOCK sgFEPATH®a INCLUDE DUCT SMOKE DETECTORS SHALL SHUT DOWN <br /> MIC EXISTING REMOTE MICROPHONE SPRM 8996 W/STI 9110 REFRIGERANT LEAK DETECTION x DRAWN BY: LB <br /> THEIR RESPECTIVE FANS AND CAUSE A "SUPERVISORY" <br /> NAc EXISTING NOTIFICATION POWER SUPPLY ALTRONIx AL1002-ULADA SIGNAL ON THE CPU PER NFPA 90A. SEE SCOPE OF FILE NAME: <br /> ALL FIRE ALARM SYSTEM CIRCUIT WIRING MUST ANNUNCIATE A TROUBLE SIGNAL DURING OPEN MECHANICAL CONTRACTORS SHOP DRAWINGS FOR DETAILS. PROTO CYCLE: <br /> APS EXISTING AUXILIARY POWER SUPPLY ALTRONIX AL4000LX AND GROUND FAULT CONDITIONS. ADDITIONALLY ALL OUTPUT CIRCUITS(HORNS/STROBES)ARE <br /> REQUIRED TO ANNUNCIATE A TROUBLE SIGNAL DURING A WIRE TO WIRE SHORT CONDITION. THE <br /> EXISTING COOKING HOOD SUPPRESSION POINT OF CONNECTION ONLY) FIRE ALARM SYSTEM WILL BE TESTED BY THE OWNER'S REPRESENTATIVES TO THE CRITERIA OF 6. ALL NON-REQUIRED DEVICES INDICATED N THE SUBMITTAL DOCUMENT DATE: 06/22/23 <br /> 0 SYSTEM ( TABLES 10.3A AND 10.4.22 OF THE 2007 NFPA 72. <br /> SYSTEM SENSOR D4120. (IF ANY), ARE VOLUNTARILY PROVIDED AND ARE <br /> PROVIDED BY MECH DIV. PROJECT ADDRESS: <br /> O xlsnrlc DUCT SMOKE DETECTOR INSTALLED BY ELECTRICAL DIV. DESIGNATED AS "SUPPLEMENTARY" IN NATURE, AS DEFINED 1605 SE EVERETT MALL WAY <br /> (POINT OF CONNECTION ONLY) SEQUENCE OF OPERATIONS IN NFPA 72. EVERETT, WA 98208 <br /> OEXISTING REMOTE TEST SWITCH SYSTEM SENSOR RTS151KEY. <br /> 7. AUDIBLE AND VISUAL NOTIFICATION APPLIANCES ARE <br /> pT 10 NEW FORT MODULE BOSCH D9127U PROVIDED AS INDICATED ON THE PLAN. <br /> CONTRACTOR: <br /> O EXISTING SMOKE DETECTOR BOSCH D273THE w s LOW VOLTAGE SECURITIES <br /> w 8. WALMART SECURITY TECHNOLOGY WILL INSTALL THE FIRE <br /> 3 z NOTES: ALARM WHERE LEGALLY ENTITLED BY LICENSING, 16716 2ND ST E, LAKE <br /> EXISTING MANUAL PULL STATION BOSCH FMM-100 TAPS, WA 98391 w O o <br /> m a <br /> PERMITTING, CERTIFICATION OR EXEMPTION. LOCAL <br /> REMOVE a ATTN: MARK SHAW <br /> VC ALL SUPERVISED VOLUME CONTROL WHEELOCK SAFEPATH®4 SP-SVC 0 0 w I,�j 3 p_ o N W CONTRACTOR TQ BL USED ELSEWHERE. <br /> a o v 253-315-1439 <br /> 15cd.y0�20�275cd WHEELOCK E90-24MCC-FW w 3 a w MARKLVSQYAHOO.COM <br /> Ego ExlsnNCFORI ow aeluNs Locnnoss OBE MULTI cd TAPPED®z WATTS 0 o O o w w L LL w CENTRAL <br /> STATION TO <br /> 9. OFF PREMISES, AUTOMATIC EMERGENCY NOTIFICATION WILL <br /> BE VIA 2 APPROVED MEANS OF COMMUNICATION TO <br /> N w zw E WAL <br /> ExISTINc -MART'S UL LISTED (UUFX) CENTER. SEE UL FILE <br /> 115cd CEILING MOUNT SPEAKER/STROBE CEILING MOUNT SPEAKER/STROBE w z U U z O m <br /> _ WHEELOCK S8-24MCCH-Fw-115od 0 g - < a-> < < a #S3152-1 FOR CERTIFICATE INFORMATION. <br /> HIGH CANDELA TAPPED 0 2 WATTS U.O.N. o N w U 3 F <br /> O <br /> 0' 0 0 0 0> ` o < 10. WIRING WILL BE INSTALLED PER (THE NEC) NFPA 70 AND <br /> 75cd Op 75cd WHEELOCK SS-24MCC-FW Z Z Z Z Z O O Z U <br /> EXISTINCCEILING MOUNT SPEAKER/STROBE MULTI CANDELA o o z O O o,i, z o J J ALL OTHER APPLICABLE SECTIONS. ALL EQUIPMENT SHALL <br /> TAPPED®z wgrs U.S.N. < >w < > < < BE PROPERLY LISTED PER NFPA 72. <br /> - - - - - - w <br /> 75cd WHEELOCK ET70WP-2475W-FR U U U U U U cE ac a <br /> ®Wp 1 NEW WALL MOUNT WE SPEAKER/STROBE «-40'C=115 d 7TC=180cd < < < < < <m < < � 1- 0 0 11. THIS SYSTEM IS DESIGNATED AS A "PROPRIETARY Z C.HE <br /> TAPPED 0 2 WATTS U.S.N. X X X X x ACTIVATES HORN/STROBE LIGHTS SUPERVISING STATION SYSTEM" IN ACCORDANCE WITH OT��F WASI, <br /> 15cd OR 75cd CEILING MOUNT SPEAKER/STROBE WHEELOCK <br /> 2 NEW MULTI CANDELA,HIGH FIDELITY E90H-24MCC-FW-MULTI od TRANSMIT ALARM SIGNAL To APPROVED CENTRAL NFPA 72 WITH 24 HOURS OF STAND-BY POWER THEN 5 1 c <br /> -1�-E90 TAPPED®2 WATTS U.O.N. X x x X X STATION ALARM MONITORING SERVICE STORE MANAGEMENT N "ALARM" PER NFPA 72. <br /> WF EXISTING WATERFLOW ALARM PRESSURE SWITCH POTTER VSR-F(PROVIDED& MINUTES ~INSTALLED BY FIRE SPRINKLER DIV) TRANSMIT SUPERVISORY SIGNAL To APPROVED PERSONNEL ARE DESIGNATED FOR 1 HOUR RUNNER <br /> HP EXISTING HIGH AIR suPERVlsoftv SWITCH POTTER PS-4 o(PROVIDED& X X X CENTRAL STATION ALARM MONITORING SERVICE SERVICE. 9 30465 fie. <br /> INSTALLED BY FIRE SPRINKLER DIV 12. F <br /> POTTER PS-40(PROVIDED& X X X X TRANSMIT TROUBLE SIGNAL TO APPROVED " C)STE`v <br /> LP EXISTING LOW AIR SUPERVISORY SWITCH R <br /> INSTALLED BY FIRE SPRINKLER DIV CENTRAL STATION ALARM MONITORING SERVICE 12. THESE NOTES DO NOT SUPERCEDE REQUIREMENTS OF ONAL EN <br /> EXISTING WATER FLOW INDICATOR SWITCH POTTER VSR-F(PROVIDED BY FIRE X ACTIVATES AHU RTU UNIT TO SHUTDOWN OTHER TRADES, SPECIFICALLY INCLUDING MECHANICAL. EXPIRES 10-z4-zoz4 <br /> SPRINKLER DIV / <br /> EXISTING SUPERVISORY TAMPER SWITCH POTTER PCV1-1(PROVIDED BY X ACTIVATES WP NOTIFICATION ABOVE FDC 13. APPLICABLE STATE AND LOCAL MODIFICATIONS ADOPTED Date Signed:June 30,2023 <br /> fCC1��CCC FIRE SPRINKLER ER x X X +xx OVERRIDE DELAY EGRESS SYSTEM RELEASE FIRE DOOR THROUGH DUE PROCESS OF LAW AND WHICH CONFLICT <br /> END OF LINE RESISTOR/DEVICE PER MANUFACTURER WITH THESE NOTES SHALL SUPERCEDE AND COPIES <br /> X <br /> WP WEATHERPROOF SHOULD BE CONVEYED TO THE CONTACT PERSON ELECTRONIC <br /> CELL 1 NEW CELLULAR DIALER MODULE BOSCH B450&B444 INDICATED BELOW. FIRE <br /> WIRE LEGEND DIRECT FIRE ALARM RELATED (ONLY) COMPLIANCE ISSUES TO: PROTECTION <br /> A COMMUNICATION CIRCUIT3pr THE EXISTING FIRE ALARM EQUIPMENT SHALL SACRAMENTO ENGINEERING CONSULTANTS RISER, <br /> #18 AM FPL COMPLY WITH NFPA 72 10.6.5 REGARDING CIRCUIT 10555 OLD PLACERVILLE RD DETAILS, & <br /> B VISUAL NOTIFICATION CIRCUIT <br /> PAIGE 12 AM SIAMESE IDENTIFICATION AND ACCESSIBILITY (10.6.5.2.1), SACRAMENTO, CA 95827 <br /> G RE TE MIC <br /> OAS CIRCUIT 3pr MECHANICAL PROTECTION 10.6.5.3 , AND PHONE: 916-368-4468 CALCS. <br /> ( ) FAX: 916-368-4490 <br /> D MULTIPLE CABLES OVERCURRENT PROTECTION (10.6.5.5) EMAIL: rh©saceng.com <br /> PLENUM RATED CABLE FPLP SHALL BE UTILIZED IN PLENUM RATED CEILING AREAS ONLY SHEET: <br /> EEE3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.