21 D9412GV4 Series Control Panels <br /> • Custom keypad text is fully programmable, including Programmable Passcode-controlled Menu List <br /> remote programming The system prompts users to enter a passcode prior to <br /> • Full function command menu including Custom viewing the keypad menu. The keypad display shows <br /> Functions the user the menu options allowed according to the <br /> • Authority by area and 16-character name for each user's authority level. Passcode-controlled menus <br /> user provide users only with the options and information <br /> • 14 custom authority levels control user's authority to pertinent to them, simplifying system operation. <br /> change, add, or delete passcodes or access control <br /> credentials; to disarm or bypass points; and to start Flexible Control <br /> system tests The system provides the flexibility to select added <br /> convenience or high security. For example, you can <br /> Area Configurations restrict passcode arming and disarming to a keypad's <br /> Area programming offers a wide selection of different immediate local area, even if the user has access to <br /> system configurations. Each area is assigned an other areas. This is particularly useful for high security <br /> account number to define annunciation, control, and areas, where a user may have access to the area, but <br /> reporting functions. Multiple areas can be linked to a would prefer to only disarm the area individually rather <br /> shared area which is automatically controlled (hallway than with the rest of the system. Another option is to <br /> or lobby). Area arming can be conditional on other program the system to disarm all areas the user can <br /> areas (master or associate). Any area can be access from any keypad. <br /> configured for perimeter and interior arming, not <br /> requiring a separate area for this function. Invisible Walk Test <br /> A menu item allows the user to test invisible 24-hour <br /> Custom Functions points within the scope of the keypad without sending <br /> For added convenience, Custom Functions can be a report to the central station. <br /> programmed to eliminate keystrokes for users allowing <br /> the installer to program an easy command for a System Users <br /> complicate function. For example, a custom function The system supports up to 1000 users, each can have <br /> can be written to bypass a group of points and arm a passcode, an access token and a wireless keyfob <br /> the system, allowing the user to perform this function (NEW). User passcodes contain three to six digits. <br /> with one easy command. This can be used to control a Passcodes can be assigned to one of 14 customized <br /> particular room, or even a single door allowing authority levels in each area, and can be restricted to <br /> customized access. In additions, Custom Functions operate only during certain times. <br /> can be activated with a token or card, or automatically Communication Formats <br /> as a scheduled event (SKED) providing further The D9412GV4 Control Panel prioritizes and sends <br /> flexibility and ease of use. reports in Contact ID or Modem Illaz communications <br /> Door-Activated Custom Function formats to four route groups. Each group has a <br /> A custom function activates when user credentials are programmable primary and backup destination. <br /> presented to a D9210C Access Control Interface The D9412GV4 provides flexible communications for <br /> Module door controller's reader. The custom function most central stations with reporting capabilities such <br /> behaves as though the user performed a function at as: <br /> the keypad associated with the door controller. Individual point numbers <br /> • Opening or closing reports by user and area number <br /> Passcode Security Remote programming attempts <br /> For high security applications, GV4 can be configured Diagnostic reports <br /> for several different passcode options. <br /> • Dual Authentication — requires a user to enter their IP Communication <br /> passcode and also use a token or card (NEW). The D9412GV4 uses the B420 Ethernet <br /> • Two-Man Rule- Requires two people with two unique Communication Module (NEW), DX4020 and/or the <br /> passcodes to be present at the time of opening. ITS-DX4020-G Cellular Communicator to communicate <br /> • Early Ambush -Allows users to verify that the facility with the Conettix D6600 and D6100i Communications <br /> is safe by requiring two passcode entries at the same Receiver/Gateways. Using Conettix IP communication <br /> keypad, sending a duress event if the user does not offers a secure path that includes anti-replay/anti- <br /> enter the passcode a second time after inspecting the substitution features and provides enhanced security <br /> premises. with encryption. The B420, DX4020 and ITS-DX4020-G <br /> Easy Exit Control can all be used for remote programming. <br /> The D9412GV4 Control Panel changes from one armed GV4 is the first Security Control panel to support DNS <br /> state to another armed state without disarming. For (Domain Name System) for both remote programming <br /> example, if you change the state from Perimeter Arm and central station communication. DNS provides ease <br /> to Master Arm, the control panel complies and reports of use, eliminating the need to use static IP addresses <br /> the change. Easy Exit Control reduces the number of as your reporting destination and accommodates a <br /> keystrokes, simplifying system operation. simple solution for central station disaster recovery. <br />