My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1605 SE EVERETT MALL WAY WALMART 2025-09-10
>
Address Records
>
SE EVERETT MALL WAY
>
1605
>
WALMART
>
1605 SE EVERETT MALL WAY WALMART 2025-09-10
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/10/2025 2:48:40 PM
Creation date
8/21/2025 12:35:01 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1605
Tenant Name
WALMART
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
273
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D9127 Series POPIT Modules <br /> Region Certification D8125 to POPIT Loops <br /> Use one two-wire data expansion loop, or distribute <br /> CSFM see our website the POPITs on up to three loops. The maximum <br /> FDNY- 6059[D9412GV3&D7412GV3] lengths shown in the following table are for all data <br /> CoA expansion loops combined connected to the same <br /> D8125 module. Setting DIP switches on the POPIT <br /> FDNY 6174 CoA modules assigns them to point numbers. The switch <br /> setting on each POPIT assigns it a point number, <br /> FDNY- 6196 regardless of its physical location. <br /> CoA <br /> POPIT to Sensor Loops <br /> Australia CTICK C Tick The number of detection devices each sensor loop can <br /> Canada ULC AMCX7.S1871-Central Station Alarm supervise is limited only by the resistance on the loop. <br /> Units Certified for Canada Resistance on each sensor loop must be less than <br /> ULC AOTX7.S1871 Local Alarm Units Certi- 100 Q not including the end-of-line (EOL) resistor. <br /> fied for Canada Certain UL and National Fire Protection Association <br /> ULC APAW7.S1871 Police-station-connec- (NFPA) applications can limit the number of detection <br /> ted Alarm Units Certified forCanada devices. Consult the appropriate UL or NFPA <br /> standards. <br /> ULC APOU7.S1871 Proprietary Alarm Units Terminate each POPIT sensor loop with the 33 kf1 EOL <br /> Certified for Canada resistor included with each POPIT. <br /> ULC NBSX7.S1871 Household Burglar Alarm Use a twisted-pair wire (six twists per foot) in all <br /> System Units Certified for Canada POPIT installations for both the data expansion loop <br /> Instal ration notes wiring and the POPIT sensor loops. Run wires away <br /> •nf - from AC sources to prevent AC induction. <br /> Compatibility Information Parts included <br /> Control Panels All G Series control panels,D9412,D7412, <br /> D7212,D7212131,D9112,D9112131, Quantit Component <br /> D8112G1,D8112G2,and D9124 y <br /> Module D8125 1 PORT module <br /> The D8125 Multiplex Zone Expander is required. The 1 33 kO EOL resistor <br /> D9127 modules are wired in parallel on the D8125 1 Magnet(D9127T only) <br /> data loop. <br /> Number of POPIT Modules per Control Panel 1 Hardware pack <br /> D7212G,D7212GV2,D7212GV3 32 D9127 POPITs 1 Literature pack <br /> D7212131 40 D9127 POPITs Technical specifications <br /> D7212,D7412,D7412G,D7412GV2, 67 D9127 POPITs Environmental Considerations <br /> D7412GV3 <br /> Relative humidity Up to 93%non-condensing <br /> D9124 119 D9127 POPITs <br /> Temperature 0°C to+50°C(+32°F to+122T) <br /> D9112B1 126 D9127 POPITs (operating) <br /> D9112,D9412,D9412G,D9412GV2, 238 D9127 POPITs Properties <br /> D9412GV3 <br /> Wiring Considerations Color Off white <br /> Dimensions 8.1 cm x 3.8 cm x 2.4 cm <br /> Wire Size Maximum Length of all Data <br /> (3.2 in.x 1.5 in.x 0.9 in.) <br /> Expansion Loops Combined <br /> 0.8 mm(22 AWG) 549 m(1800 ft) Material UL Listed fire-resistant <br /> 1.0 mm(20 AWG) 881 m(2890 ft) <br /> 1.2 mm(18 AWG) 1402 m(4600 ft) <br /> 1.5 mm(16 AWG) 2231 m(7320 ft) <br /> 1.8 mm(14AWG) 3551 m(11650ft) <br />
The URL can be used to link to this page
Your browser does not support the video tag.