My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1605 SE EVERETT MALL WAY WALMART 2025-09-10
>
Address Records
>
SE EVERETT MALL WAY
>
1605
>
WALMART
>
1605 SE EVERETT MALL WAY WALMART 2025-09-10
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/10/2025 2:48:40 PM
Creation date
8/21/2025 12:35:01 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1605
Tenant Name
WALMART
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
273
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A <br /> Page 1 of 2 <br /> �an&Associates, Inc. <br /> Field <br /> Geotechnical Engineering•Environmental Engineering Report NO.:09623350DFRIO182023MPS <br /> Construction Testing and Inspection <br /> DATE: 10/18/2023 Set Count: CONTRACTOR: ESI <br /> PROJECT#: 09623350 PERMIT#: <br /> PROJECT: Walmart 3053 INSPECTOR: Madhab Paudel/Nima Sherpa <br /> LOCATION: 1605 SE Everett Mall Way JURISDICTION: City of Everett <br /> KA P.M.: Jeff Mercer WEATHER: Cloudy TEMP:52'F <br /> A Krazan and Associates, Inc. representative was on site today for material testing& inspection. Upon arriving on <br /> site met with contractor and location, design & other requirements were noted. While on site we did following <br /> inspection: <br /> Reinforcing Steel Placement: We observed the placement of reinforcing steel for insulated concrete slab @ freezer <br /> area.We verified the placement of reinforcing steel for size,grade,count,spacing,clearances,lap and general overall <br /> placement. In our opinion,the reinforcing steel was placed in general conformance to the approved structural plans <br /> and specifications(Refer 2/S1). <br /> Concrete Placement: Total 5 cubic yards of(Smokey Point) concrete was poured on insulated slab @ freezer area <br /> had mix no. 0240P with minimum design compressive strength 4000 psi at 28 days. The concrete had acceptable <br /> level of slump&temperature. The concrete was poured via mechanical wheelbarrow. One set of 4x8 cure concrete <br /> cylinders were cast. Reference the concrete report 09623350CR10182023MP. <br /> J <br /> ;r <br /> .a <br /> Offices Serving the Western United States <br /> Lynnwood(425)485-5519•Poulsbo(360)598-2126•Tacoma(253)939-2500 <br /> The information provided on this report is prepared for the exclusive use of the client.This report may not be reproduced in any format without the written permission of the client and K—an&Associates.This report <br /> indicates our inspectors observation and testing results based on site conditions and contractor activities.This information is subject to review prior to final submittal.By signing this report,our inspector does not accept <br /> responsibility for validity of results.The same information has been provided by others on site.The test results apply only to the specific locations,and items inspected or tested.Template date 4/20/2023 <br />
The URL can be used to link to this page
Your browser does not support the video tag.