Laserfiche WebLink
Architects and Engineers Specifications <br /> 4 Zone Class B Speaker Splitter <br /> The Wheelock SP4Z-A/B shall be UL Standard 864, 9th edition, California State Fire Marshal (CSFM)and New York City(MEA) <br /> approved, 2-Zone Class A or 4-Zone Class B Speaker Splitter for operation with the Wheelock, SP40S, SP40/2, SPB-80/4, SPB- <br /> 160 and SPB-320. The SP4Z-A/B shall enable a single supervised speaker audio output to drive up to two Class A supervised <br /> speaker audio outputs or four Class B supervised speaker audio outputs. Each Class A zone shall be capable of accepting up to <br /> 40 watts and operate on either 25 or 70.7V RMS of audio input. Each Class B zone shall be capable of accepting up to 40 watts of <br /> audio and operate on either 25 or 70.7V RMS of audio input.The SP4Z-A/B shall be capable of supporting live microphone paging, <br /> prerecorded emergency voice evacuation messages, supervised background music and general paging announcements. <br /> The SP4Z-A/B shall mount inside the enclosure of the SP40S,SP40/2,SPB-80/4,SPB-160 and SPB-320 and shall have power and <br /> trouble LED's with individual zone short and open LED indication. The SP4Z-A/B shall be capable of detecting wiring faults. The <br /> SP4Z-A/B shall be powered by 24VDC,which is to be supplied by the SP40S, SP40/2,SPB-80/4,SPB-160 or SPB-320. Standby <br /> and Alarm current at 24VDC shall be 15mA. Removable wiring terminals for quick connect/disconnect accepting 12-22 AWG shall <br /> be incorporated. All output circuitry shall be power limited. Space shall be provided to allow for naming of the zones. <br /> Addressable Paging Splitter and Telephone Zone Controller <br /> The Wheelock Addressable Paging Splitter(SP4-APS) and Telephone Zone Controller (SP4-TZC) shall be used to control and <br /> direct telephone paging and background music zones connected to the SAFEPATH4 Multi-Function Facility Communication System <br /> using an RS485 connection. <br /> The Addressable Paging Splitter (SP4-APS) shall be UL Standard 864, 9th edition and California State Fire Marshal (CSFM) <br /> approved, addressable and supervised 2-zone Class A or 4-zone Class B Speaker splitter. The SP4-APS shall be used with <br /> Wheelock's SP40S or SP40/2 panel and the Audio Booster(SPB-160,SPB-80/4,and SPB-320)panels.Each SP4-APS shall have <br /> a single audio input capable of 25 Vrms or 70.7 Vrms at a maximum of 80 Watts.The input audio power shall be distributed to the <br /> zone connections with the total not exceeding the input and no zone exceeding 40 Watts. When audio boosters are connected, <br /> each audio booster module shall consume 1.2 Watts from the total input power of the SP4-APS. The splitter shall be mounted <br /> inside the SP40S, SP40/2 or Audio Booster that it is associated with, and it shall operate on 24VDC supplied by the supported <br /> module.The SP4-APS shall contain 16 LED indicators used to monitor and troubleshoot the module. <br /> The Telephone Zone Controller Module(SP4-TZC)shall be used to address the output zones on the SP4-APS.The SP4-TZC shall <br /> be capable of supporting 17 SP4-APS speaker splitter modules and shall be capable of addressing all zones at once("All Call"),a <br /> maximum of 68 separate zones, 17 fixed zone groups and 9 programmed logical zone groups.This shall be accomplished using <br /> two digit DTMF tones from a page port, an unused CO port, or a stand alone telephone with a loop start circuit.Also, the SP4- <br /> TZC shall be able to select zones for background music. The SP4-TZC has the following inputs: Power, USB port, Background <br /> Music(BGM), Page Audio in. The outputs are:Audio out and RS485 Digital Control.The basic operating parameters of the SP4- <br /> APS shall be pre-programmed. Customized programming shall be accomplished using a USB cable and programming computer <br /> software.The SP4-TZC shall be powered using a 24VDC filtered and regulated power supply such as the Wheelock RPS-2406. <br /> The Controller Module assembly is mounted in a metal enclosure measuring 13"L x 7 5/8"W x 2"D. <br /> Supervised Volume Control <br /> The Wheelock SP-SVC shall be UL Standard 864,9th edition approved,supervised volume control for use with the SAPEPATH°4 <br /> Facility Communications System. <br /> The SP-SVC shall provide for manual volume setting for telephone paging and background music for a specific speaker or speaker <br /> zone. The selected adjustment will not affect the volume setting of emergency prerecorded messages or live microphone usage. <br /> The SP-SVC shall be capable of handling up to 35 watts of audio power @ 70.7 volts or 4 watts audio power @ 25 volts and shall <br /> operate on either 70.7 or 25 volt input from an SP40S or Audio Booster. The SP-SVC shall be capable of operating in Class B or <br /> Class A wiring configurations (for Class A, the SP4-APS is required). The SP-SVC shall receive operating power from an Audio <br /> Booster, SP40S or SP40/2. Volume adjustment settings shall be off, 1 — 10, in 3dB increments. The SP-SVC shall be supplied <br /> with a stainless steel mounting plate with a black knob and require a double gang, 3'/2"deep back box for mounting. <br /> Remote Microphone <br /> The Wheelock SPRM shall be UL Standard 864, 9th edition and California State Fire Marshal (CSFM) approved, Remote <br /> Microphone for use with the SAFEPATH14 Facility Communications System. <br /> The SPRM shall be a supervised hand held push to talk microphone and a key shall be required to enable remote microphone <br /> use. (Same key as SP40S or SP40/2) Removable wiring terminals for quick connect/disconnect accepting 12—22 AWG shall be <br /> incorporated. All output circuitry shall be power limited. Individual front panel LED's shall be provided for indication of System <br /> Normal,System Trouble and Alarm. Multiple on board diagnostic LED's shall be provided. When used with the SP40S or SP40/2, <br /> the priority level shall be number two. Remote microphone usage shall disengage background music and general paging. <br /> Voice frequency response shall be 275 Hz-6.5 kHz+/-2.4 dB. Power requirements shall be 24VDC and will be supplied by the <br /> SP40S or SP40/2. Input current for Standby shall be 26mA and for Alarm 38mA. Audio output level shall be 1.05V RMA. There <br /> shall be a 6-wire connection to the SP40S or SP40/2. The mounting plate shall be red and measure, 8 3/4"x 5 '/4", and shall fit <br /> into a 4 gang back box. <br /> 15 <br />