My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1605 SE EVERETT MALL WAY WALMART 2025-09-10
>
Address Records
>
SE EVERETT MALL WAY
>
1605
>
WALMART
>
1605 SE EVERETT MALL WAY WALMART 2025-09-10
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/10/2025 2:48:40 PM
Creation date
8/21/2025 12:35:01 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1605
Tenant Name
WALMART
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
273
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PRODUCT DATA SHEET 9cp applied technologies <br /> RECOVER° <br /> Hydration stabilizer <br /> ASTM C494 Type D <br /> Product Description <br /> Recover8 is a ready-to-use aqueous solution of chemical compounds specifically designed to <br /> stabilize the hydration of Portland cement concretes. The ingredients are factory pre-mixed in exact <br /> proportions under strict quality control to provide uniform results. One gallon weighs approximately <br /> 9.6 Ibs (1.15 kg/L). <br /> Uses Set Time Control <br /> Recover is used to stabilize mixer wash water and returned or Recover is also used in situations where a controlled set time <br /> leftover concrete for extended periods, allowing for use of extension is required. Examples include: extended hauls, large <br /> the materials when specified or allowed. It is also used where continuous pours or pre-batching of concrete for later use. <br /> controlled extended set of concrete is needed. It is the concrete <br /> user's responsibility to determine if leftover, returned or Performance <br /> extended-set concrete is specified or allowed. <br /> Recover stabilizes the hydration process of Portland cement <br /> Wash Water preventing it from reaching initial set. This stabilization is not <br /> permanent and is controlled by dosage rate. For wash water, <br /> For wash water applications, Recover is used to eliminate the the Recover treated water is mixed or sprayed in a specific <br /> need to discharge wash water from the mixer. This allows the manner to thoroughly coat the interior of the mixer.The water is <br /> wash water to be used as mix water in the next batch of concrete used as mix water in the next batch of concrete produced,which <br /> produced and prevents the residual plastic concrete from hardening. then scours the unhardened material from the interior of the <br /> Stabilization of up to 96 hours is possible depending on dosage mixer. Stabilization of returned or leftover concrete with Recover <br /> rate. maintains the plasticity of the concrete for the desired storage <br /> duration. This stabilized concrete then resumes normal hydration <br /> Returned Concrete when the Recover dosage effects subside,or when it is activated <br /> For returned or leftover concrete, Recover is used to prevent by the addition of fresh concrete and/or an accelerator.The result <br /> plastic concrete from reaching initial set.This allows the concrete can be concrete with normal plastic and hardened properties. <br /> to be stored in a plastic state and then used when specified or <br /> allowed. The use of this concrete may require the addition of Addition Rates <br /> freshly batched concrete and/or an accelerator such as Daraccel® <br /> or PolarSet®. Addition rates of Recover for wash water range from 6 to 128 fl oz <br /> (180 to 3800 mL) per treatment. The amount used will depend <br /> Stabilization of concrete for up to 96 hours is possible depending on the specific materials involved, mixer type and stabilization <br /> on dosage rate.Use prevents the waste of unused concrete. period. Addition rates for returned or leftover concrete will <br /> range from 3 to 128 fl oz/100 Ibs(195 to 8350 mL/100 kg)of <br /> cement. The amount used will depend on the specific materials <br /> Product Advantages involved, concrete age, temperature conditions and stabilization <br /> period. For applications requiring set time extensions well in <br /> • Eliminates the need to discharge wash water excess of 4 hours, Recover may be used at addition ranges from <br /> from the mixer 5 to 50 oz/100 Ibs (325 to 3260 mL/100 kg) of cement For <br /> • Prevents the waste of unused concrete use as a traditional ASTM Type D retarder, Recover may be <br /> used at addition rates of 2 to 6 oz/100 Ibs (130 to 390 mL <br /> • Provides predictable extended set for continuous /100 kg) of cement. Proper dosage rate selection can only be <br /> placement on mass concrete and tremie projects, achieved through pretesting. Consult your local GCP Applied <br /> or on long hauls to remote sites Technologies admixture representative. <br />
The URL can be used to link to this page
Your browser does not support the video tag.