Laserfiche WebLink
AIR CURTAIN SCHEDULE MECHANICAL SYMBOLS <br /> AREA WEIGHT FAN MOTORS ELECTRICAL DATA <br /> MARK SERVED MANUFACTURER MODEL (LBS) HP 110LTS PH FLA MCA MOCP NOTES 18"x12" RECTANGULAR DUCT 18"WIDE <br /> AC 1 OGP BERNER CHD10-2072A 169 0.75 120 1 16.0 20.0 25 A,H,I,K,M BY 12"DEEP <br /> POWEREDAIRE ETA 2-72 <br /> GENERAL INFORMATION(ALL DEVICES): 12"4! 12"DIAMETER ROUND DUCT <br /> 1. AIR CURTAINS FURNISHED AND INSTALLED BY CONTRACTOR. <br /> 2. PROVIDE A DEDICATED ELECTRICAL CIRCUIT FOR EACH AIR CURTAIN WHEN MULTIPLE AIR CURTAINS ARE INSTALLED AT A SINGLE OPENING. <br /> SUPPLY DUCT IN SECTION <br /> NOTES: <br /> A. FURNISH WITH FACTORY MOUNTED NON-FUSED TOGGLE DISCONNECT SWITCH LOCATED ON TOP OF AIR CURTAIN. RETURN OR EXHAUST DUCT IN <br /> B. FURNISH WITH MANUFACTURER'S 120V PHOTOELECTRIC SENSOR SWITCH,SENSOR REFLECTOR,AND REQUIRED ACCESSORIES TO ENERGIZE ALL AIR CURTAINS SECTION <br /> AT EACH DOOR ON HIGH SPEED WHEN DOOR OPENS AND DE-ENERGIZE AIR CURTAINS WHEN DOOR CLOSES. <br /> C. UNIT SHALL BE TOP MOUNTED.FOR CURTAIN INSTALLATIONS NOT DETAILED ON ARCHITECTURAL DRAWINGS,SUSPEND CURTAINS FROM UNISTRUT INSTALLED �--I <br /> BELOW DOOR TRACK AND SPANNING ENTIRE DOOR OPENING AS REQUIRED.SUPPORT UNISTRUT FROM STRUCTURE. ELBOW WITH TURNING VANES <br /> D. AS REQUIRED,ALL OPENINGS WITH TWO AIR CURTAINS TO BE FURNISHED WITH A FIELD MOUNTED AND WIRED RELAY TO ALLOW FOR ONE SWITCH TO ACTIVATE III lii <br /> TWO AIR CURTAINS. <br /> E. BERNER UNIT SHALL BE FURNISHED WITH FACTORY INSTALLED SINGLE PHASE CONTROL PANEL,LEFT END. <br /> F. BERNER UNIT SHALL BE FURNISHED WITH TANDEM PERFORMANCE KITS. TEE WITH TURNING VANES <br /> G. BERNER UNIT SHALL BE FURNISHED WITH FACTORY INSTALLED INTELLISWITCH DIGITAL CONTROLLER. <br /> H. FURNISH WITH A FIELD MOUNTED AND WIRED 24V MAGNETIC LIMIT DOOR SWITCH AND TIME DELAY TO ENERGIZE AIR CURTAIN WHEN DOOR OPENS AND <br /> CONTINUE OPERATION FOR 60 SECONDS AFTER DOOR CLOSES. ROUND(OR OVAL)ELBOW "-' <br /> I. FURNISH WITH MANUFACTURER'S WALL MOUNTING PLATE FOR INSTALLATION ABOVE DOOR OPENING WITH BOTTOM OF UNIT FLUSH WITH TOP OF DOOR.IF AIR a z„LLp "'gF <br /> CURTAIN MUST BE OFFSET TO CLEAR DOOR HARDWARE OR OTHER OBSTRUCTION,UNIT SHALL BE TOP MOUNTED AND SUPPORTED FROM STRUCTURE. <br /> REFERENCE MECHANICAL AIR CURTAIN INSTALLATION DETAIL. �N ow>u LLrc VOLUME/BALANCE DAMPER aoa <br /> J. INSTALL BOTTOM OF AIR CURTAIN NO HIGHER THAN B'-0"AFF.INSTALL PER MANUFACTURER'S INSTRUCTIONS. Z �Yz 0wo= y =F <br /> K. AIR CURTAIN SHALL BE TESTED IN ACCORDANCE WITH ANSI/AMCA 220. u = <br /> L. UNITS SHALL BE BLACK IN COLOR. SUPPLY AIR DIFFUSER WITH g 3Qi <w <br /> M. BERNER FURNISHED WITH FACTORY INSTALLED FAN SPEED CONTROL WITH TAMPER PROOF COVER. ROUND SUPPLY DUCT o ak w o G y z g <br /> RETURN OR EXHAUST AIR DIFFUSER <br /> ao « <br /> AIR DEVICE SCHEDULE WITH ROUND DUCT <br /> MARK SERVICE MANUFACTURER MODEL STYLE FRAME TYPE FACE SIZE NOTES 24"x24" BRANCH DUCT AND/OR NECK SIZE u <br /> CD SUPPLY AIR TUTTLE&BAILEY S1200 ROUND NECK LAY-IN I..x24" B,D,E CD DIFFUSER OR GRILLE TYPE <br /> E.H.PRICE SCD CEILING DIFFUSER 450 CFM <br /> CARNES SFTB 0 $ <br /> CD1 SUPPLY AIR TUTTLE&BAILEY M ROUND NECK SURFACE REFER TO B,E,I,L,M,N C <br /> E.H.PRICE SMD CEILING DIFFUSER MOUNT DRAWINGS O THERMOSTAT U s <br /> CARNES SKFA <br /> RAG1 SUPPLY AIR TUTTLE&BAILEY M 1/2"xi/2"x1/2" SURFACE REFER TO C,E,I,M,N OS TIMER f2 <br /> E.H.PRICE SMD EGGCRATE MOUNT DRAWINGS < `N <br /> CARNES SKFA CEILING GRILLE <br /> TEMPSENSOR <br /> RAW RETURN AIR TUTTLE&BAILEY T75 FIXED BLADE SURFACE REFER TO B,E,I <br /> SX <br /> E.H.PRICE 510Z WALL GRILLE MOUNT DRAWINGS 0 w <br /> CARNES RSRBH CONNECT TO EXISTING p <br /> SAW SUPPLY AIR TUTTLE&BAILEY T64 LOUVERED FACE SURFACE REFER TO B,E,F,H <br /> E.H.PRICE 52ODS REGISTER MOUNT DRAWINGS ETR EXISTING TO REMAIN <br /> CARNES RTDBV <br /> VOLUME/BALANCE DAMPER SCHEDULE <br /> FIRE DAMPER <br /> TYPE MANUFACTURER/MODEL FD <br /> ROUND AES/WMVCD O 0 Z <br /> RUSKIN/WMRS25 O O O <br /> RECTANGULAR AES/AMD4 O 0 <br /> RUSKIN/WMD25 U1 Q <br /> GENERAL INFORMATION(ALL DEVICES): <br /> 1. INSTALL BOTTOM OF WALL MOUNTED AIR DEVICES AT ELEVATION INDICATED ON DRAWINGS UNLESS NOTED OTHERWISE. <br /> 2. BALANCE DAMPER CONTACTS:❑ _ N ~ <br /> AES-(800)786-0402 (n <, a <br /> RUSKIN-(816)761-7476 Q O <br /> o W0 <br /> NOTES: W� o <br /> A. 6-WAY(DBi-DB3)OR 4-WAY(DB4-DB8)THROW UNLESS SHOWN OTHERWISE WITH FLOW ARROWS ON PLAN. W Z <br /> N <br /> B. ALL STEEL CONSTRUCTION. j W <br /> C. ALL ALUMINUM CONSTRUCTION. W V <br /> D. BRANCH DUCT SIZE SHALL BE SAME AS NOTED DIFFUSER NECK SIZE UNLESS NOTED OTHERWISE. O U J LU O N <br /> E. STANDARD WHITE FINISH. <br /> F. PROVIDE NECK FOR DUCT CONNECTION. L N <br /> G. DROP BOX DIFFUSERS FURNISHED BY OWNER INSTALLED BY CONTRACTOR.REFERENCE SPECIFICATIONS. Lt.l <br /> H. PROVIDE INTEGRAL OPPOSED BLADE DAMPERS ON ALL DRUM LOUVERS ON DROP BOXES WITH BRANCH DUCTWORK ATTACHED TO THE SUPPLY PLENUM. <br /> I. PROVIDE MANUFACTURER'S OPPOSED BLADE DAMPER ACCESSIBLE THROUGH FACE UNLESS NOTED OTHERWISE. W <br /> J. PROVIDE WITH FASTENERS FOR COMPLETE(NON-HINGED)REMOVABILITY OF GRILLE.DO NOT PROVIDE FILTER UNLESS NOTED OTHERWISE. w <br /> K. TWO 2"SLOTS WITH MANUFACTURER'S INSULATED PLENUM(TUTTLE&BAILEY LP,PRICE JSPI,CARNES CXPC.) <br /> L. REFER TO PLANS FOR DIRECTIONAL ARROWS INDICATING CFM THROWS FOR PROPER GRILLE SELECTION.NO DIRECTIONAL ARROWS INDICATES 4-WAY <br /> THROW. <br /> M. PROVIDE ROUND NECK ADAPTER 0 <br /> N. PROVIDE CEILING TRANSITION REGISTER BOX WITH 16"OR 24"PLATE FOR ROUGH-IN. <br /> ISSUE BLOCK <br /> City of Everett Permit Review <br /> EVERETT Status:Reviewed for Permit <br /> 12/01/2023 12:04:29 PM <br /> CHECKED BY: JEE <br /> DRAWN BY: RGD <br /> PROTO: 90 <br /> PROTO CYCLE: 11/11/22 <br /> DOCUMENT DATE: 02/22/23 <br /> TOP BEAM <br /> CLAMP TYP <br /> 3" <br /> MAX TOP CHORD OF JOIST ROOF <br /> ROOF <br /> 2"x2"x1/4"ANGLE OR <br /> 6" 1 5l8"xi 5l8"UNISTRUT <br /> NOT FOR <br /> DUCT HANGER STRAP <br /> 6" <br /> REF SPECIFICATIONS CONSTRUCTION <br /> REFSTRUCTURALFOR LOADS MUST BE LOADS MUST BE <br /> BOTTOM OF <br /> ATTACHMENT HUNG WITHIN 3" 1"MIN. HUNG WITHIN 3" <br /> OF PANEL POINTS STRUCTURE OF PANEL POINTS <br /> REFSTRUCTURALFOR REFSTRUCTURAL <br /> MOUNTING DETAIL THREADED ROD SCREWS TYP <br /> TYP 60"MAX. <br /> SHEET METAL <br /> RECTANGULAR DUCT REFSTRUCTURAL <br /> 2"x2"xi/4"ANGLE OR <br /> RECTANGULAR DUCT 1 5/8"x1 5/8"UNISTRUT RECTANGULAR DUCT <br /> OFFSET AWAY NOTE:AIR CURTAIN IS REQUIRED TO BE PERPENDICULAR TO STRUCTURE PARALLEL TO STRUCTURE <br /> FROM WALL INSTALLED 3/8 INCH(BERNER)OR 1/2 INCH <br /> AIR CURTAIN (POWERED AIRE)AWAY FROM WALL FOR LOADS MUST BE <br /> EVERY INCH ABOVE CLEAR DOOR OPENING <br /> DOOR OPTIONAL ROUTING BEAM CLAMP <br /> HARDWARE HUNG WITHIN R IN CONCEALED DUCT HANGER STRAP <br /> (IF APPLICABLE) �( MAX OF PANEL POINTS AREAS REF SPECIFICATIONS <br /> 1` 3^ REFSTRUCTURAL <br /> ROOF ROOF <br /> OFFSET ABOVE CLEAR <br /> DOOR OPENING 2"x2"xi/4"ANGLE OR <br /> TOP OF 1 5/8"x1 5/8"UNISTRUT <br /> ENTRY DOOR <br /> 6„ 6 <br /> L=W/4,4"MIN <br /> 'tJ <br /> /, /` BOTTOM OF <br /> STRUCTURE LOADS MUST BE <br /> 0 <br /> p� ��tf <br /> DUCT HANGER STRAP OF PANEHUNG IL PIOINTS <br /> �Q�' REF SPECIFICATIONS .AO � SCREWS TYP <br /> 0 go DUCTSUPPORTBAND <br /> EXTERIOR INTERIOR I ARUND DUCT PPLY ��`5 �SO3 SAME SIZE AS STRAP MECHANICAL <br /> / LOAD RATED 7,6 <br /> FASTENERS DETAILS AND <br /> NOTES: W SCHEDULES <br /> 1.ENSURE AIR CURTAIN INSTALLATION ALLOWS PROPER DOOR OPERATION,AIR CURTAIN AIRFLOW, SUPPLY REGISTER,REF FLOOR PLAN FOR SIZE <br /> ❑ AND ACCESS TO AIR CURTAIN AND DOOR HARDWARE(IF APPLICABLE)FOR MAINTENANCE. AND LOCATION,MOUNT REGISTERS @ 30 DEGREE <br /> 2.AIR CURTAIN IS REQUIRED TO BE OFFSET FROM WALL IF INSTALLED HIGHER THAN 1"ABOVE DOOR ANGLE DOWN FROM HORIZONTAL IN OPEN OFFICES <br /> ❑ OPENING. AND STOCKROOM AREA,EXCEPT THOSE ROUND SUPPLY <br /> 3.FOLLOW MANUFACTURER'S INSTALLATION INSTRUCTIONS AND POST-INSTALLATION AIRFLOW SHOWN ON BOTTOM OF DUCT ON THE PLAN AIR DUCT <br /> ❑ PATTERN VERIFICATION,REF SPECIFICATIONS. NOTES: <br /> 1.SPIN-IN FITTINGS W/SCOOPS ARE NOT ACCEPTABLE PERPENDICULAR TO JOIST PARALLEL TO JOIST <br /> 2.REF PLANS FOR RUNOUT SIZES <br /> 3.45"LEAD IN <br /> 0IAIR CURTAIN INSTALLATION �,�HIGH EFFICIENCY BRANCH DUCT FITTING �DUCT SUPPORT AND GRILLE SHEET: <br /> NTS L NTS <br /> NTS ^n 2 <br />