My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2227 GRAND AVE 2025-09-11
>
Address Records
>
GRAND AVE
>
2227
>
2227 GRAND AVE 2025-09-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/11/2025 1:29:38 PM
Creation date
8/21/2025 2:43:03 PM
Metadata
Fields
Template:
Address Document
Street Name
GRAND AVE
Street Number
2227
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
62
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AND LARGER. ALL REINFORCING BAR BENDS SHALL BE MADE COLD WITH A <br /> MINIMUM RADIUS OF 6 BAR DIAMETERS (1'-7"MINIMUM). CORNER BARS (2'-0" <br /> BEND) SHALL BE PROVIDED FOR ALL HORIZONTAL REINFORCEMENT. LAP ALL <br /> BARS A MIND"OF 48 BAR DIAMETERS UNLESS NOTED OTHERWISE. UNLESS <br /> NOTE OTHERWISE ON THE DRAWINGS REINFORCING STEEL SHALL HAVE THE <br /> FOLLOWING MINIMUM COVER: <br /> CONCRETE CAST AGAINST EARTH 3 INCHES <br /> CONCRETE EXPOSED TO EARTH OR WEATHER: <br /> 46 THROUGH#18 BARS 2 INCHES <br /> #5 BAR AND SMALLER 1-1/2 INCHES <br /> STRUCTURAL TIMBER: <br /> ALL LUMBER SHALL CONFORM TO WWPA GRADING RULES FOR WESTERN <br /> LUMBER,LATEST EDITION. PROVIDE CUT WASHERS UNDER ALL NUTS AND <br /> BOLTS BEARING AGAINST WOOD. ALL WOOD IN CONTACT WITH CONCRETE <br /> SHALL BE PRESSURE TREATED IN ACCORDANCE WITH AWPA UI AND M4 <br /> STANDARDS. ALL STRUCTURAL LUMBER SHALL BE AS NOTED BELOW: <br /> 4X BEAMS DOUG-FIRILARCH#2---Fb=850PSI <br /> 6X BEAMS DOUG-FIR/LARCH#2----Fb=850PSI <br /> LUMBER NOT NOTED HEM-FIR#2-------------Fb=850 PSI <br /> MISCELLANEOUS HANGERS TO BE SIMPSON OR APPROVED EQUAL. ALL <br /> HANGERS SHALL BE FASTENED TO WOOD WITH PROPER NAILS. ALL HOLES <br /> SHALL BE NAILED. MACHINE BOLTS TO BE A-307. ANCHOR BOLTS INTO <br /> CONCRETE SHALL BE 5/8 INCH DIAMETER WITH 7 INCHES OF EMBEDMENT INTO <br /> CONCRETE UNLESS NOTED OTHERWISE ON THE PLANS. ALL NAILS SHALL BE <br /> COMMON WIRE NAILS. NAILING SHALL BE IN ACCORDANCE WITH THE CURRENT <br /> I.B.C. SCHEDULE. <br /> STRUCTURAL LAAHNATED LUMBER(GRADE 2.0) <br /> Fb=2600 PSI <br /> E=2,000,000 PSI <br /> Fv=285 PSI <br /> FLOOR SHEATHING: <br /> SHEATHING SHALL BE 3/INCH TONGUE AND GROOVE A.P.A.RATED SHEATHING. <br /> SPAN RATING 48/24 WITH LONG DIMENSION PERPENDICULAR TO SUPPORTS. <br /> UNLESS NOTED OTHERWISE NAIL WITH 8d COMMON NAILS AT 6 INCHES ON <br /> CENTER.AT SUPPORTED PANEL EDGES AND 10 INCHES ON CENTER AT <br /> INTERMEDIATE SUPPORTS. THE FLOOR SHEATHING SHALL BE GLUED TO THE <br /> JOIST AND THE TONGUE AND GROOVE JOINTS WITH AN APPROVED ADHESIVE. <br />
The URL can be used to link to this page
Your browser does not support the video tag.