Laserfiche WebLink
4. 50 feet setback from slopes greater than 15 percent and greater than 10 feet in height. <br /> 5. All underground stormwater facilities shall be setback from any structure or property line a distance <br /> equal to the depth of the ground disturbed in setting the structure. <br /> Infiltration trenches may be located under pavement if a small yard drain or catch basin with grate cover is <br /> placed at the end of the trench pipe such that overflow would occur out of the 2019 Stormwater Management <br /> Manual for Western Washington Volume V - Chapter 4 - Page 707 catch basin at an elevation at least one foot <br /> below that of the pavement, and in a location which can accommodate the overflow without creating a <br /> significant adverse impact to downhill properties or drainage systems. This is intended to prevent saturation of <br /> the pavement in the event of system failure. <br /> 6. Applicable access requirements of DCSS 4-4.2 (3) have been met. <br /> 7. Filter fabric shall be placed over the drain rock as shown on Figure V-4.1: Typical Downspout <br /> Infiltration Trench prior to backfilling. <br /> 8. Does this project include infiltration of runoff from pollution generating surfaces? <br /> Yes. Treatment is required and shall be designed per the 2019 SWMMWW. <br /> Indicate type and sizing of treatment that will be provided prior to infiltration (provide BMP number, and sizing of <br /> BMP). <br /> No. No treatment required. <br /> City of Everett Public Works <br /> Small Project Stormwater Site Plan Report for Projects in 18 <br /> the Combined Sewer Area-April 2021 <br />