Laserfiche WebLink
i Permit Inspections <br /> V E R E T T City of Everett <br /> WASHINGTON <br /> Non code horizontal wet vent system.Lav drain and vertical vent must be 2"through roof. Per UPC chap 9-Grade of drains must be sloped to 2%per <br /> UPC chap 7.Currently all drains are back-graded.-(drains and vents below flood level),Vertical to horizontal and horizontal to horizontal changes of <br /> direction must be with approved long sweep fittings per UPC chap 7.***Joists to be drilled per building code. <br /> 2/26/2025 2/26/2025 PLUMB 03--ROUGH JEFF M RHODE APPROVAL see notes <br /> Notes: <br /> notes from plumbing final that should have been a rough in <br /> 9/30/2024 1:45:20 PM(JEFF M RHODE) <br /> -corrections made from previous inspection <br /> 4/10/2025 4/10/2025 PLUMB 08 FINAL** JEFF M RHODE CORRECTION see notes <br /> REQUIRED <br /> Notes: <br /> 4/6/2025 9:23 PM Brian Hughes <br /> Contact Name:Brian Hughes <br /> Site Address:2501 OAKES AVE <br /> Phone:2062936390 <br /> e-Mail:madderscience@gmail.com <br /> -hammer arrestor required for dishwasher water connection-gravity drainage hose on air gap back graded <br /> 4/11/2025 4/11/2025 PLUMB 08-FINAL** JEFF M RHODE APPRVD-PERMIT see notes <br /> FINAL <br /> Notes: <br /> 4/10/2025 8:06 PM Brian Hughes <br /> corrected D/W Drain and added water hammer arrestor on hot water side supply under sink. <br /> Contact Name:Brian Hughes <br /> Site Address:2501 OAKES AVE <br /> Phone:2062936390 <br /> e-Mail:madderscience@gmail.com <br /> -kitchen and bath in upstairs unit ok <br /> I <br /> Printed:Thursday,28 August,2025 2 of 2 rk <br /> SUPERION <br />