My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3106 44TH ST SE 2017 Plans 2025-08-28
>
Address Records
>
44TH ST SE
>
3106
>
Plans
>
3106 44TH ST SE 2017 Plans 2025-08-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/28/2025 2:35:51 PM
Creation date
8/28/2025 1:11:30 PM
Metadata
Fields
Template:
Address Document
Street Name
44TH ST SE
Street Number
3106
Permit
C1703-026
Year
2017
Notes
SFR BASIC/2015 IRC RB1502-004
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IS <br />3020 "C SECOND FLOOR ELECTRICAL PLAN <br />1/4 "=l $_0" <br />REGISTERS IN CEILING <br />THIS PLAN U.N.O. <br />ELECTRICAL LEGEND <br />DUPLEX RECEPTACLE OUTLET <br />DUPLEX RECEPTACLE OUTLET <br />SPLIT WIRED (SWITCH TOP HALF) <br />MWo DUPLEX RECEPTACLE OUTLET <br />MICROWAVE <br />DIRECTIONAL INCANDESCENT <br />CEILING MOUNTED LIGHT <br />INCANDESCENT RECESSED <br />CEILING LIGHT <br />INCANDESCENT WALL <br />MOUNTED LIGHT <br />SINGLE RECEPTACLE OUTLET <br />208v (R: RANGE, D: DRYER) O DOUBLE TUBE FLUORESCENT <br />CEILING MOUNTED LIGHT <br />Q JUNCTION BOX <br />SINGLE POLE SWITCH <br />$3 THREE WAY SWITCH <br />DIM.$ DIMMER SWITCH <br />$T <br />TIMER SWITCH <br />24 HR CLOCK TIMER - <br />AUTOMATIC <br />SMALL FLUORESCENT <br />STRIP LIGHT <br />-OP <br />PENDANT LIGHT <br />RECESSED HEAT LAMP - <br />NUTONE 9410H, 250W LAMP <br />CEILING FIXTURE <br />HEAT LAMP, EXHAUST <br />FAN COMBINATION RECESSED <br />CEILING FIXTURE - 250W LAMP <br />50 CFM MIN, 4.0 SONES, <br />4" ROUND DUCT <br />RECESSED CEILING <br />EXHAUST FAN <br />50 CFM MIN, 1.5 SONES, <br />4" ROUND DUCT <br />L <br />MICROWAVE OVEN/RANGE <br />HOOD COMBINATION — <br />MW <br />EXHAUST FAN TO PROVIDE <br />A MIN. OF 100 CFM. <br />METER CENTER <br />INCANDESCENT CEILING <br />ELECTRICAL PANEL <br />MOUNTED LIGHT <br />(D <br />THERMOSTAT <br />© <br />CARBON MONOXIDE <br />SMOKE DETECTOR <br />DETECTOR <br />FLOOR REGISTER <br />©RECESSED <br />CEILING WHOLE HOUSE <br />EXHAUST FAN MEETING CFM <br />TEL r <br />TELEPHONE JACK <br />WHF <br />REQUIREMENTS OUTLINED IN IRC <br />TELEVISION JACK <br />SECTION M1057.3. <br />+84" ABV. <br />SLAB, TYP. <br />1/4"=1'-0" <br />+84" ABV. <br />SLAB, TYP. <br />GENERAL NOTES <br />+84" ABV. <br />SLAB, TYP. <br />ELEVATION OF ELECTRICAL OUTLETS A.F.F. <br />AT KITCHEN REVISED. <br />FIRST FLOOR ELECTRICAL PLAN <br />THIS ELECTRICAL PLAN IS THE ARCHITECT'S SUGGESTED <br />LAYOUT. THE ELECTRICAL CONTRACT IS ON A DESIGN -BUILD <br />BASIS. ELECTRICAL CONTRACTOR'S DESIGN SHALL BE <br />APPROVED BY THE OWNER AND SHALL CONFORM TO THE <br />APPLICABLE ELECTRIC CODE REGARDLESS OF WHAT IS SHOWN <br />ON THIS DRAWING. <br />ALL SWITCHES, OUTLETS AND ENVIRONMENTAL CONTROLS <br />SHALL BE MOUNTED NOT LESS THAN 15" NOR MORE THAN 48" <br />ABOVE FINISHED FLOOR AND SHALL BE ALIGNED VERTICALLY. <br />APPLIANCES DESIGNED TO BE FIXED IN POSITION SHALL BE <br />SECURELY FASTENED IN PLACE. <br />WATER HEATERS SHALL BE ANCHORED OR STRAPPED AT <br />POINTS WITHIN THE UPPER 1/3 OR LOWER 1/3 TO RESIST <br />EARTHQUAKE MOTION. <br />LIGHT FIXTURES THAT SERVE TO ILLUMINATE INTERIOR STAIRS <br />SHALL BE LOCATED IN THE IMMEDIATE VICINITY OF EACH STAIR <br />LANDING AND SHALL PROVIDE A MIN. LIGHTING LEVEL OF 1 <br />FOOT-CANDLE MEASURED AT CENTER OF TREADS AND <br />LANDINGS PER IRC R303.7. <br />ENERGY NOTES <br />SEE ENERGY NOTES ON SHEET D1. <br />FURNACE AND WATER HEATER SHALL BE FUELED BY <br />NATURAL GAS. THE PILOTS, BURNERS, HEATING ELEMENTS <br />AND SWITCHES SHOULD BE A MINIMUM OF 18" ABOVE THE <br />GARAGE FLOOR. <br />REGISTERS IN CEILING <br />THIS PLAN U.N.O. <br />DUCT AND VENTILATION NOTES <br />VENTILATION: SEE NOTES ON COVER SHEET. <br />KITCHEN EXHAUST FAN TO BE 100 CFM MIN. AND SHALL VENT <br />TO OUTSIDE. <br />ALL EXHAUST DUCTS SHALL BE RIGID METAL, AND SHALL BE <br />FITTED WITH A TIGHT FITTING BACGGAFT DAMPER CAPABLE OF <br />CLOSING WHEN THE FAN IS NOT IN USE. <br />DUCTS IN UNHEATED SPACES INCLUDING ATTICS SHALL BE <br />INSULATED TO A MINIMUM OF R-4. <br />TOP FLOOR EXHAUST FANS SHALL VENT THROUGH ROOF. <br />MECHANICAL VENTILATING SYSTEMS IN BATHROOMS AND <br />LAUNDRY ROOMS SHALL EXHAUST DIRECTLY TO THE OUTSIDE. <br />DUCTS PENETRATING OCCUPANCY SEPARATION BETWEEN <br />GARAGE AND DWELLING, AND WITHIN THE GARAGE SHALL BE <br />CONSTRUCTED OF NO. 26 GAUGE SHEET STEEL. <br />DRYER EXHAUST DUCT SHALL BE 4" RIGID METAL WITH A 4" <br />OPENING ON THE EXHAUST HOOD. THE DRYERS SHALL BE <br />GENERAL ELECTRIC. DRYER SHALL BE INSTALLED ACCORDING <br />TO MANUFACTURER'S INSTALLATION INSTRUCTIONS ON SITE. <br />5052 REGISTERED <br />ARCHITECT <br />ROBERT E. WEIBLE <br />STATE OF WASHINGTON <br />-a <br />a� <br />N <br />a� <br />L <br />N <br />�C <br />.V <br />Q <br />V1 <br />C <br />d. <br />O <br />�> <br />Z <br />� <br />N <br />V <br />•F� <br />V <br />L <br />Q <br />T3 <br />a <br />ZE <br />0 <br />0 <br />c� <br />� <br />s <br />a <br />� <br />cs. <br />a <br />v <br />�o <br />o� <br />CO <br />a <br />0 <br />0_ <br />�o <br />a <br />o� <br />M <br />O <br />u <br />L <br />m <br />3 <br />a <br />L <br />= <br />7 <br />ui <br />0 <br />a <br />tt <br />0 <br />U <br />C. <br />0 <br />E <br />N <br />.c0 <br />V? <br />._ <br />Ei <br />0 <br />Z <br />M <br />> <br />W <br />a <br />tm <br />._ <br />0 <br />a <br />Job No.: 14-38 <br />Sheet No.: <br />