3106 44TH ST SE 2017 Plans 2025-08-28
>
Address Records
>
44TH ST SE
>
3106
>
Plans
>
3106 44TH ST SE 2017 Plans 2025-08-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/28/2025 2:35:51 PM
Creation date
8/28/2025 1:11:30 PM
Metadata
Fields
Template:
Address Document
Street Name
44TH ST SE
Street Number
3106
Permit
C1703-026
Year
2017
Notes
SFR BASIC/2015 IRC RB1502-004
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
K <br />- a <br />10Y2 5'-10" 2" 3'-6" <br />A. <br />7T @ 10" EA. <br />IL <br />SECOND 16 15 14 13 12J 11 10 9 <br />FLOOR <br />DN <br />1 Y2"O HANDRAIL AT <br />34" TO 38" ABOVE NOSING 7 <br />1 Y2" BETWEEN g <br />HANDRAIL & WALL 5 <br />HALF WALL 113 <br />+39" ABOVE 112 <br />NOSING TYP. <br />FLOOR UP <br />ABOVE 3'-6" <br />16 EQUAL RISERS = 10'-1 %" FIRST <br />MAX. RISER HEIGHT: 7-Y4" FLOOR <br />MIN. TREAD WIDTH: 10" <br />1/4"=1'-0" <br />N O T E S <br />30'-0" <br />14'-0" 9" . 15'-3" <br />3'_5j/2" 5,_3j/4" 5'-3JI4„ <br />E , <br />1 I <br />E E <br />3-6 L SH 2-0 13-6 SH <br />SAFETY GLAZING SAFET ( GLAZING <br />. w <br />N <br />3'x 5' N 1 <br />= LDR <br />48x3 OP IN TUB �, 0 <br />SHOWER <br />• <br />• <br />2X6 WALL <br />• M. Bath 8 4'-13`4" <br />24" TB <br />. w <br />9 <br />• TP `� -? v <br />EVA <br />7'-O)l 5'-O" 1.4'-0» <br />E <br />1 l <br />' LOW ROOF ' <br />E E <br />4-6 <br />I <br />t E <br />{E i <br />� 1 <br />4 4- 0 SL 4-6 4--0SL <br />12 EGRESS <br />D2 <br />• <br />o AN, <br />k Master Bedroom <br />13'-4%2' 7,--9" -4 HC3-7%2" <br />I 2,_5„ 5'-7Y 10'-10» <br />1 <br />d- 1 W.I.C. 2_0 <br />f <br />LO BIFOLD <br />5 SH. N CN <br />w , <br />, I N <br />I � <br />i 1 ¢ I� <br />L in N CL I r <br />_l N <br />o -o DN <br />AB �" Bedroto <br />om 2 <br />I o � <br />a LO w n I _ <br />122"X3 " <br />o ; p I ATII 1 DRYER <br />E1 ? 3'-1�2" 5'-3Y2" 2'-9Y2" 2,_4„ IACCE , Lndry. <br />d- �— — —t <br />2-6 HC <br />o WASHER <br />FRAMING: 2x6's AT 16" OC EXTERIOR WALLS <br />INSULATE AND WEATHER STRIP ALL ATTIC <br />2x4's AT 16" OC INTERIOR WALLS <br />ACCESS HATCHES. PROVIDE ' A MINIMUM OF <br />UNLESS NOTED OTHERWISE. <br />30" OF HEAD ROOM ABOVE ALL HATCHES. <br />CONCEALED SPACES SHALL BE FIRESTOPPED <br />ALL PLUMBING VENTS SHALL BE LOCATED <br />IN BOTH DIRECTIONS AT 10'-0" ON CENTER <br />ON REAR SIDE OF ROOF RIDGE. <br />AND AT FLOORS. TYPICAL. <br />OPENINGS BETWEEN GARAGE AND RESIDENCE <br />FIREBLOCKING SHALL ALSO BE AT <br />SHALL BE EQUIPPED WITH SOLID WOOD DOORS <br />INTERCONNECTIONS BETWEEN VERTICAL <br />NOT LESS THAN 1%" IN THICKNESS, SOLID OR <br />& HORIZONTAL SPACES, BETWEEN STAIR <br />HONEYCOMB STEEL DOORS NOT LESS THAN <br />STRINGERS AT TOP &BOTTOM OF RUN, <br />13/8" THICK, OR 20-MIN. FIRE RATED DOORS <br />AT OPENINGS THROUGH CEILING & FLOOR <br />PER IRC R302.5.1 <br />AND AT CHIMNEYS & FIREPLACES. <br />ALL ESCAPE OR RESCUE WINDOWS FROM SLEEPING <br />ALL BEDROOM DOORS SHALL BE UNDERCUT <br />ROOMS SHALL HAVE A MINIMUM NET CLEAR <br />A MINUMUM OF 1/2" ABOVE THE ADJACENT <br />OPENING OF 5.7 SQUARE FEET. THE MINIMUM <br />FLOOR COVERING. <br />CLEAR OPENING HEIGHT DIMENSION SHALL BE 24". <br />MINIMUM CLEAR OPENING WIDTH DIMENSION SHALL <br />INSULATE AND WEATHER STRIP ALL CRAWL <br />BE 20". SILL HEIGHT SHALL BE NOT MORE THAN <br />SPACE ACCESS HATCHES. <br />44" ABOVE THE FLOOR. <br />GLAZING SHALL CONFORM TO 2015 IRC SECTION R308. <br />PROVIDE STREET ADDRESS AT THE FRONT OF EACH <br />UNIT. USE 3" HIGH OR LARGER NUMBERS. <br />• • • • WALL INSULATION <br />INTERIOR ELEVATIONS LOCATED ON SHEET A7 <br />INSULATION <br />WALLS: R21 FIBERGLASS BATTS OR BLANKETS <br />FLOORS OVER UNHEATED AREAS - R38 <br />ATTICS ABOVE ROOF CEILING - R49 <br />SOLID CORE WOOD DOORS TO GARAGE: U=0.20 <br />GLAZED ENTRY DOORS: U=0.28 <br />INSULATED METAL ENTRY DOORS: U=0.20 <br />WINDOWS: ALL WINDOWS SHALL HAVE A U <br />FACTOR OF 0.28 OR BETTER <br />I <br />2-$ HC <br />5' TUB 5 SH. o o ;� 0 <br />e O— <br />z N SHWR 5 SH. c� m "' , 2-6 HC <br />d- U) N �G 91 -1� 6'-11" 4,_5" <br />g <br />I <br />CV <br />• <br />• <br />• <br />• <br />• <br />. <br />. <br />I <br />. <br />. <br />• <br />I <br />I• wN <br />r- <br />I r <br />` <br />. <br />I <br />I �n <br />` <br />• <br />I 9 <br />' <br />D3 <br />3 <br />' <br />'s <br />D3 <br />2 <br />0 <br />L0 <br />dI <br />I <br />� w <br />gat RETURN a <br />45' c., <br />5° <br />N Q <br />AIR <br />2,_4" <br />I <br />o <br />I <br />\ Ld <br />� <br />'• <br />° <br />HCW <br />Bedroom 4 <br />T w2-6 <br />o <br />Ln° <br />o' <br />' <br />C <br />cn <br />Wi <br />r- <br />• <br />, <br />cnl <br />¢ <br />°' <br />m <br />17 N <br />S <br />i - <br />& P 2-6 HCW <br />-. <br />w <br />'N <br />1 <br />I <br />0 - <br />I <br />- <br />; <br />D2 -CO <br />• <br />AJ <br />LO <br />WALL BELOW <br />D2 <br />6-0 BIPASs <br />i <br />N <br />TYP. <br />4'-4)/2" <br />3,_4" 3'_6" <br />v <br />v <br />f <br />1 <br />5'_7" <br />; 13'-2y" <br />• Bedroom 3 <br />3 Bonus <br />; <br />D2 10 <br />j _._! <br />• <br />INSULATE FLOOR <br />; °n <br />ABOVE GARAGE <br />I <br />INSULATE FLOOR Q <br />ABOVE GARAGE <br />` EGRESS <br />INSULATE FLOOR <br />i <br />' <br />ABOVE PORCH <br />6-015-0 SL <br />8 <br />I <br />7-0 5-0 DBL SL A8 F <br />E <br />- _ _. - - - .._.._ -- <br />LOW,ROOF <br />_ _. <br />EGRESS i 3-0 0 SH <br />........... .. ....... , <br />LOW I ROOF <br />O" <br />5'-3)/2" 5 -3%2 5- 8Y2 5 -8R 11 <br />4'-O» 4' <br />10'-71$ <br />1 V-5" <br />8'-0" <br />30'-0" <br />12n <br />A <br />1/4 "=if-o" <br />t <br />N <br />T <br />A <br />30'-0" A7 <br />14'-.0" 16'-0" <br />6 ROOF ABOVE 6x6 W/ ABU <br />1 <br />02 POST BASE <br />-,T ------ - - 7 -„- - <br />7'-0»J"----�_0 5 _& <br />12 ' I ' ' I o <br />D 1 ao <br />5-0 15-0 SL I I I I <br />! I , I I I Patio <br />• I wl <br />F----� o I DWLT----- <br />i I I s 5-0 15-0 SL 5-0 5�O SL I `' <br />• <br />I <br />1 ¢ SAFETY GLAZING o <br />Kitchen co <br />• <br />• , 1 o N <br />N I <br />Qo �_ , <br />• <br />1,_0,r co wN L <br />N . <br />dO 1 <br />c� <br />• E N <br />' I 2 11 DIRECT VENT <br />110 3 ; 1'-0" o GAS APPLIANCE <br />I ; '_47 "FIREPLACE" I : 17 <br />D1 <br />I � I I. o <br />-------------j ! I : 10 I <br />Great Room ; D3Lo <br />4 -3 52_0" ;..... <br />i INSULATE FLOOR <br />1 PANTRY 5�2„ RN OVER CRAWLSPACE <br />3 -5/ CAB 1o'-1" d- of N <br />LLO <br />2X6 WALL <br />EDGE OF SOFFIT 18 x24 CRAWL .- <br />1 SPACE ACCESS I <br />i (+7'-10" A.F.F N <br />: • <br />■ TYP.) z <br />TOP OF WALL <br />I C1 I I I I o <br />0 AT +39" A.F.F. I l I 6� I I I f I U N <br />B Dining ' ' ' I; ' ' 4x POST - <br />i::I {---I- I I ABOVE ►� <br />A7 A7 I..i <br />N LO �' i <br />' I `- <br />I <br />N I. I in <br />1..1 2x6 WALL w �. <br />I1 NCD <br />o <br />1 <br />• /� <br />I : 3 LOOR o , �. <br />� i� <br />D2 �I - °BOVE N <br />x N N O <br />• 2X6 A • <br />WALL :. ... .. $... , ..... 45 ; 1 <br />• 7.... N..�. 1 x °° <br />• - ` 3'U �» <br />- i..•...••..•r..•....•.......••.•.••.......r•.•... .•r.• ; <br />• f wdr: <br />• I........: HAL WALL <br />sl1E ; :N . 2x6 WALL ` TYP. <br />.:. <br />.. .. ... ; • +39" ABOVE i <br />: ... w T. <br />.. ...' ............ , .. ... 0 <br />• \ — : <br />_........ _ . .-.. .................................................: 2 8 INSU NOSING TYP. Z <br />CLOS G N <br />SOFFIT CEILING y 2x6 WALL <br />TO + 8'_ 1 " A.F.F. 2 o <br />8'-111 „ D2 „ I !.......; ...1 = Ent co � <br />42"x12" WOOD TREAD L - - - 4 Q <br />• 12 <br />" ; <br />MAX. RISER 73/4" 4 _0 SAFETY D1 ; D2 <br />SOFFIT CEILING GL ZING o <br />TO +8'-1" A.F.F.. 2x6 WALL <br />1-0 5-10 F I I <br />I I <br />E <br />2'-6" , 2'_9" 2'-9» I <br />O <br />I <br />STUD WALL HEIGHT 8'-1" <br />ABOVE FIN. FLOOR <br />SEE SHEET A7 FOR TOP <br />OF WINDOW HEIGHT <br />A7 <br />5052 REGISTERED <br />ARCHITECT <br />ROBERT E. WEIBLE <br />STATE OF WASHINGTON <br />N <br />Q <br />t/1 <br />O <br />,> <br />z <br />eta <br />Ce <br />N <br />02 <br />Q <br />c <br />Q <br />o <br />0 <br />a <br />z <br />-a <br />�- <br />r <br />00 <br />y <br />.. <br />0 <br />CO <br />o <br />o <br />v- <br />M <br />O <br />L <br />o <br />m <br />0 <br />3 <br />= <br />e <br />UM <br />n <br />0 <br />zt <br />r <br />20 <br />Garage 1 ,� <br />N v� CEILING FINISH f ,''►� <br />1 LAYER V$" TYPE 'X' GWB 36" HIGH RAIL j 0 <br />FIRE -TAPED <br />INSULATE FLOOR ABOVE j _ CL <br />Porch ' *j Q <br />w <br />0) <br />0 <br />1 7 <br />IN <br />■> <br />- <br />2x8 FRAMING FOR <br />I D1 <br />� <br />y <br />cii <br />A <br />ELEC. ENTRANCE <br />01 <br />14" CLEAR INSIDE. <br />t <br />�4 <br />`1- <br />16-0I7-0 SOHD <br />FLOOR ABOVE <br />----------- <br />- <br />4) <br />5 L----------- ---- <br />D2 6 <br />- ------� <br />5 <br />» <br />1 L <br />4 <br />3 -O <br />16'-0" D1 <br />3'-0" <br />6'-0„ <br />A8 <br />■.. <br />a. <br />STUD WALL HEIGHT 9'-1" <br />30'-O" ABOVE FIN. FLOOR <br />0 <br />A SEE SHEET A7 FOR TOP Q <br />3020M FIRST FLOOR PLAN A7 OF WINDOW HEIGHT o <br />0 <br />1/4 o <br />Job No.: 14-38 <br />Sheet No.. <br />