Laserfiche WebLink
3020 mA SECOND FLOOR ELECTRICAL PLAN <br />REGISTERS IN CEILING <br />THIS PLAN U.N.O. <br />ELECTRICAL LEGEND <br />-& DUPLEX RECEPTACLE OUTLET <br />4tr- DUPLEX RECEPTACLE OUTLET <br />SPLIT WIRED (SWITCH TOP HALF) <br />MW'9'-- DUPLEX RECEPTACLE OUTLET <br />MICROWAVE <br />DIRECTIONAL INCANDESCENT <br />CEILING MOUNTED LIGHT <br />INCANDESCENT RECESSED <br />CEILING LIGHT <br />r'1 INCANDESCENT WALL <br />Y MOUNTED LIGHT <br />SINGLE RECEPTACLE OUTLET <br />208v (R.: RANGE, D: DRYER) O DOUBLE TUBE FLUORESCENT <br />CEILING MOUNTED LIGHT <br />JUNCTION BOX <br />SINGLE POLE SWITCH <br />$3 THREE WAY SWITCH <br />DIM.$ DIMMER SWITCH <br />�T <br />TIMER SWITCH <br />24 HR CLOCK TIMER — <br />AUTOMATIC <br />SMALL FLUORESCENT <br />STRIP LIGHT <br />PPENDANT <br />LIGHT <br />H RECESSED HEAT LAMP — <br />NUTONE 9410H, 250W LAMP <br />CEILING FIXTURE <br />HEAT LAMP, EXHAUST <br />FAN COMBINATION RECESSED <br />CEILING FIXTURE — 250W LAMP <br />50 CFM MIN, 4.0 SONES, <br />4" ROUND DUCT <br />RECESSED CEILING <br />EXHAUST FAN <br />50 CFM MIN, 1.5 SONES, <br />4" ROUND DUCT <br />L J <br />MICROWAVE OVEN/RANGE <br />HOOD COMBINATION — <br />Mw <br />EXHAUST FAN TO PROVIDE <br />A MIN. OF 100 CFM. <br />METER CENTER <br />INCANDESCENT CEILING <br />o <br />ELECTRICAL PANEL <br />MOUNTED LIGHT <br />THERMOSTAT <br />CARBON MONOXIDE <br />® <br />SMOKE DETECTOR <br />DETECTOR <br />FLOOR REGISTER <br />RECESSED CEILING WHOLE HOUSE <br />EXHAUST FAN MEETING CFM <br />TEL V <br />TELEPHONE JACK <br />WHF <br />REQUIREMENTS OUTLINED IN IRC <br />SECTION M1057.3. <br />TV <br />TELEVISION JACK <br />+84" ABV. <br />SLAB, TYP. <br />ELEVATION OF ELECTRICAL OUTLETS A.F.F. <br />AT KITCHEN REVISED. <br />3020 "A FIRST FLOOR ELECTRICAL PLAN <br />1/4 "=i 1-0" <br />REGISTERS IN CEILING <br />THIS PLAN U.N.O. <br />GENERAL NOTES <br />THIS ELECTRICAL PLAN IS THE ARCHITECT'S SUGGESTED. <br />LAYOUT. THE ELECTRICAL CONTRACT IS ON A DESIGN —BUILD <br />BASIS. ELECTRICAL CONTRACTOR'S DESIGN SHALL BE <br />APPROVED BY THE OWNER AND SHALL CONFORM TO THE <br />APPLICABLE ELECTRIC CODE REGARDLESS OF WHAT IS SHOWN <br />ON THIS DRAWING. <br />ALL SWITCHES, OUTLETS AND ENVIRONMENTAL CONTROLS <br />SHALL BE MOUNTED NOT LESS THAN 15" NOR MORE THAN 48" <br />ABOVE FINISHED FLOOR AND SHALL BE ALIGNED VERTICALLY. <br />APPLIANCES DESIGNED TO BE FIXED IN POSITION SHALL BE <br />SECURELY FASTENED IN PLACE. <br />WATER HEATERS SHALL BE ANCHORED OR STRAPPED AT <br />POINTS WITHIN THE UPPER 113 OR LOWER 113 TO RESIST <br />EARTHQUAKE MOTION. <br />LIGHT FIXTURES THAT SERVE TO ILLUMINATE INTERIOR STAIRS <br />SHALL BE LOCATED IN THE IMMEDIATE VICINITY OF EACH STAIR <br />LANDING AND SHALL PROVIDE A MIN. LIGHTING LEVEL OF 1 <br />FOOT—CANDLE .MEASURED AT CENTER OF TREADS AND <br />LANDINGS PER IRC R303.7. <br />ENERGY NOTES <br />SEE ENERGY NOTES ON SHEET D1. <br />FURNACE AND WATER HEATER SHALL BE FUELED BY <br />NATURAL GAS. THE PILOTS, BURNERS, HEATING ELEMENTS <br />AND SWITCHES SHOULD BE A MINIMUM OF 18" ABOVE THE <br />GARAGE FLOOR. <br />DUCT AND VENTILATION NOTES <br />VENTILATION: SEE NOTES ON COVER SHEET. <br />KITCHEN EXHAUST FAN TO BE 100 CFM MIN. AND SHALL VENT <br />TO OUTSIDE. <br />ALL EXHAUST DUCTS SHALL BE RIGID METAL, AND SHALL BE <br />FITTED WITH A TIGHT FITTING BACGGAFT DAMPER CAPABLE OF <br />CLOSING WHEN THE FAN IS NOT IN USE. <br />DUCTS IN UNHEATED SPACES INCLUDING ATTICS SHALL BE <br />INSULATED TO A MINIMUM OF R-4. <br />TOP FLOOR EXHAUST FANS SHALL VENT THROUGH ROOF. <br />MECHANICAL VENTILATING SYSTEMS IN BATHROOMS AND <br />LAUNDRY ROOMS SHALL EXHAUST DIRECTLY TO THE OUTSIDE. <br />DUCTS PENETRATING OCCUPANCY SEPARATION BETWEEN <br />GARAGE AND DWELLING, AND WITHIN THE GARAGE SHALL BE <br />CONSTRUCTED OF NO. 26 GAUGE SHEET STEEL. <br />DRYER EXHAUST DUCT SHALL BE 4" RIGID METAL WITH A 4" <br />OPENING ON THE EXHAUST HOOD. THE DRYERS SHALL BE <br />GENERAL ELECTRIC. DRYER SHALL BE INSTALLED ACCORDING <br />TO MANUFACTURER'S INSTALLATION INSTRUCTIONS ON SITE. <br />5052 REGISTERED <br />ARCHITECT <br />A&ioL-L <br />7OF <br />E. WEIBLE <br />STWASHINGTON <br />L <br />N <br />�C <br />a7 <br />�L <br />t/1 <br />C <br />d.. <br />O <br />.T <br />�> <br />V <br />Z <br />N <br />4- <br />V <br />_V <br />Q <br />'a <br />a <br />L <br />�c <br />6 <br />Q <br />� <br />s <br />a <br />�L <br />o <br />o_ <br />0 <br />v <br />o <br />QZ <br />o� <br />o <br />a <br />t0 <br />� <br />00 <br />U) <br />a� <br />+- <br />a <br />0 <br />� <br />cC <br />to <br />� <br />an <br />as <br />a <br />o <br />r <br />O <br />r <br />M <br />O <br />m <br />a <br />= <br />� <br />a <br />L <br />W <br />O <br />0 <br />r <br />11 <br />r <br />O <br />L <br />tCi <br />CL <br />c <br />N <br />>N <br />O <br />E <br />0 <br />C? <br />y <br />� <br />L <br />� <br />Z <br />(L <br />= <br />> <br />W <br />= <br />0 <br />0) <br />>% <br />i <br />.- <br />cl) <br />0 <br />a <br />Job No.: 14-38 <br />Sheet No.: <br />