Laserfiche WebLink
STRUCTURAL NOTES C C <br /> (THESE NOTES ARE TYPICAL UNLESS NOTED OR DETAILED OTHERWISE ON DRAWINGS) ENGINEERING <br /> CODE CONCRETE COVER ON REINFORCING 250 4TH AVE. S., SUITE 200 <br /> LEGEND EDMONDS, WASHINGTON 98020 <br /> ALL MATERIALS,WORKMANSHIP,DESIGN,AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH: 3" PHONE (425) 778-8500 <br /> SPECIFICATIONS,AND THE INTERNATIONAL BUILDING CODE(IBC),2021 EDITION.SPECIFICATIONS AND STANDARDS DEFINITION SYMBOL DEFINITION SYMBOL FAX (425) 778-5536 <br /> WHERE REFERENCED ON THE DRAWINGS ARE TO BE THE LATEST EDITION. CONCRETE EXPOSED TO EARTH AND WEATHER: <br /> #6 BARS AND LARGER 2" DIRECTION OF NATIVE SOIL III=11 III=11 <br /> DESIGN LOADS #S BARS AND SMALLER 11/2" FRAMING <br /> EXTENT OF GRANULAR FILL <br /> DEAD LOADS: CONCRETE NOT EXPOSED TO EARTH OR WEATHER: FRAMINGRAMING <br /> STORAGE RACK SELF WEIGHT 110 LBS PER RACK SLABS,WALLS AND JOISTS 3/4" <br /> LIVE LOADS: <br /> COLUMN TIES OR SPIRALS AND BEAM STIRRUPS 11/2" COLUMNS STRUCTURALSTEEL <br /> STORAGE RACK 3000 LBS PER SHELF NON-SHRINK GROUT COLUMN BEARING t" <br /> RATED SHEATHING <br /> EARTHQUAKE LOADS: NON-SHRINK GROUT SHALL BE CEMENT-BASED WITH A MINIMUM COMPRESSIVE STRENGTH OF 5000 PSI WHEN <br /> ON BEAM <br /> TESTED IN ACCORDANCE WITH ASTM C-109.GROUT SHALL BE MIXED AND PLACED IN STRICT ACCORDANCE WITH BEAM CONTINUOUS SHEAR WALL <br /> EQUIVALENT LATERAL FORCE PROCEDURE PER ASCE 7-16. THE MANUFACTURER'S RECOMMENDATIONS. SWX <br /> OVERSUPPORT (SEE SCHEDULE) <br /> SITE CLASS D(DEFAULT) STRUCTURAL STEEL ,�L <br /> SHORT PERIOD SPECTRAL RESPONSE ACCEL(Ss) 1.378 CONCRETE WALL COLUMN MARK 51- G. C <br /> ONE SECOND SPECTRAL RESPONSE ACCEL($) 0.489 STRUCTURAL STEEL DESIGN,FABRICATION AND ERECTION SHALL BE IN ACCORDANCE WITH THE AISC (SEE SCHEDULE) / 05 of XA- GS <br /> SHORT PERIOD DESIGN SPECTRAL RESPONSE ACCEL(Sos) 1.102 "SPECIFICATION FOR THE DESIGN,FABRICATION,AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS",LATEST BEARING STUD FOOTING MARK <br /> ONE SECOND DESIGN SPECTRAL RESPONSE ACCEL(SDI) 0.489 EDITION. WALL (SEE SCHEDULE) F So 0 <br /> RISK CATEGORY II <br /> SEISMIC IMPORTANCE FACTOR 00 1.0 WIDE FLANGE SHAPES SHALL CONFORM TO ASTM A992,Fy=50 KS1. NON-BEARING HOLDOW N MARK <br /> SEISMIC DESIGN CATEGORY C STUD WALL (SEE SCHEDULE) at, 3sss3 <br /> BASIC SEISMIC FORCE-RESISTING-SYSTEM STEEL STORAGE RACK PLATES,ANGLES,CHANNELS,AND RODS SHALL CONFORM TO ASTM A36,Fy=36 KSI. ysS, aC YS�' 1 <br /> RESPONSE MODIFICATION FACTOR,(R) 4.0 BEARING STUD HANGER MARK K SIONAL <br /> REDUNDANCY FACTOR(P) 1.0 STRUCTURAL TUBING SHALL CONFORM TO ASTM A500 GRADE C,RECTANGULAR/SQUARE Fy=50 K51, SHEAR WALL (SEE SCHEDULE) O <br /> SEISMIC RESPONSE COEFFICIENT(Cs) 0.276 ROUND Fy=46 K51. NON-BEARING �( FLAG NOTE WI5/25 <br /> STUD SHEAR WALL TL �— z (SEE PLAN NOTES) <br /> W=TOTAL SEISMIC DEAD LOAD AS DEFINED PER ASCE 7-16. STEEL PIPE SHALL CONFORM TO ASTM A53 GRADE B,Fy=35 K51. �j— <br /> CMU WALL STEEL MOMENT <br /> BASE SHEAR(V),V=CsW= S_wos W BOLTS CONNECTING STEEL MEMBERS SHALL CONFORM TO ASTM A325-N.BOLTS SHALL BE 3/4"0 MINIMUM,UNO FRAME CONN. �V <br /> ANCHOR BOLTS SHALL CONFORM TO ASTM A307. <br /> WIND LOADS: <br /> CONTRACTOR SHALL PROVIDE CONNECTION ADJUSTMENT TOLERANCES TO SATISFY THE REQUIREMENTS OF AISC ABBREVIATIONS <br /> BASIC WIND SPEED(3 SECOND GUST) 98 MPH MANUAL OF STEEL CONSTRUCTION. <br /> EXPOSURE B (A) ABOVE HORIZ HORIZONTAL N <br /> Kn 1.0 UNLESS SPECIFIED AS STAINLESS STEEL,ALL STEEL MEMBERS,SHAPES,BOLTS,AND ACCESSORIES EXPOSED TO qg ANCHOR BOLT KIP KING POST Z <br /> WEATHER SHALL BE HOT DIP GALVANIZED. O <br /> CONCRETE ALT ALTERNATE KSI KIPS PER SQUARE INCH Ln <br /> WELDING w <br /> ARCH ARCHITECT MECH MECHANICAL <br /> ALL CONCRETE SHALL BE MIXED,PROPORTIONED,CONVEYED,AND PLACED IN ACCORDANCE WITH CHAPTER 26 OF Q 'Z <br /> ACI318 AND THE AMERICAN CONCRETE INSTITUTE'S SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS WELDING SHALL CONFORM TO AWS"STRUCTURAL WELDING CODE",LATEST EDITION.ALL WELDING SHALL BE (g) BELOW MF MOMENT FRAME Z <br /> (ACI 301). DONE WITH 70 K5I LOW HYDROGEN ELECTRODES.WHERE NOT CALLED OUT,MINIMUM FILLET WELD SIZE SHALL BE z O <br /> PER TABLE 5.81N AWS 01.1,LATEST EDITION. BLKG BLOCKING NS NEAR SIDE C cp F <br /> ALL CONCRETE SHALL BE STONE-AGGREGATE CONCRETE HAVING A UNIT WEIGHT OF APPROXIMATELY 150 POUNDS BM BEAM Oc ON CENTER <br /> WELDING OF REINFORCING BARS SHALL NOT BE PERMITTED UNLESS SPECIFICALLY CALLED OUT ON DRAWINGS OR 0_ <br /> PER CUBIC FOOT. H W <br /> APPROVED BY STRUCTURAL ENGINEER.WELDING OF GRADE 60 REINFORCING BARS SHALL BE PERFORMED USING BOT BOTTOM OPP OPPOSITE U � N <br /> LOW HYDROGEN ELECTRODES.WELDING OF GRADE 40 REINFORCING BARS SHALL BE PERFORMED USING E70XX <br /> CONCRETE STRENGTHS AT 28 DAYS(fc)AND MIX CRITERIA SHALL BE AS FOLLOWS: ELECTRODES.SEE REINFORCING NOTES FOR MATERIAL REQUIREMENTS OF WELDED BARS.WELDING WITHIN 4"OF BTWN BETWEEN PL PLATE w w O <br /> MAXIMUM MIN CEMENT COLD BENDS IN REINFORCING BAR515 NOT PERMITTED. CIP COMPLETE JOINT PENETRATION PLCS PLACES d U <br /> TYPE OF CONSTRUCTION fc* WATER/CEMENT CONTENT PER CUBIC MAXIMUM <br /> RATIO YARD SHRINKAGE STRAIN ALL WELDING SHALL BE DONE BY WASHINGTON ASSOCIATION OF BUILDING OFFICIALS(WABO)CERTIFIED WELDERS. CUR CLEAR P51 POUNDS PER SQUARE INCH A <br /> FOOTINGS 3000 PSI 0.50 51/2 SACK N/A CMU CONCRETE MASONRY UNIT PSF POUNDS PER SQUARE FOOT W <br /> EXISTING BUILDING H .ti to <br /> COL COLUMN P/T POSTTENSIONED o <br /> THE MINIMUM AMOUNT OF CEMENT LISTED ABOVE MA V BE CHANGED IF A CONCRETE PERFORMANCE MIX IS CONTRACTOR SHALL VERIFY ALL DIMENSIONS,MEMBER SIZES AND CONDITIONS OF THE EXISTING BUILDING CONICCONCRETE PT PRESSURE TREATED O O <br /> SUBMITTED TO THE ENGINEER AND THE BUILDING DEPARTMENT FOR APPROVAL TWO WEEKS PRIOR TO PLACING DEPICTED IN THE DRAWINGS,AND NOTIFY THE STRUCTURAL ENGINEER OF ANY DISCREPANCIES FOR POSSIBLE <br /> ANY CONCRETE.THE PERFORMANCE MIX SHALL INCLUDE THE AMOUNTS OF CEMENT,FINE AND COARSE REDESIGN. CONN CONNECTION REINF REINFORCING Y <br /> AGGREGATE,WATER,AND ADMIXTURES AS WELL AS THE WATER-CEMENT RATIO,SLUMP,CONCRETE YIELD,AND CONT CONTINUOUS REQ'D REQUIRED Q <br /> SUBSTANTIATING STRENGTH DATA IN ACCORDANCE WITH CHAPTER 26 OF ACI 318. CONTRACTOR RESPONSIBLE FOR COMPLETELY SEALING ALL AREAS WHERE EXISTING ROOF MATERIAL IS <br /> PENETRATED OR REMOVED.PROVIDE WATERPROOFING AS REQUIRED BY THE ARCH. DEL DOUBLE SCHED SCHEDULE <br /> ALL CONCRETE EXPOSED TO WEATHER OR TO FREEZING TEMPERATURES SHALL BE AIR-ENTRAINED IN ACCORDANCE GENERAL DIET DETAIL SIM SIMILAR DESIGN: BTJ <br /> WITH ACI 318 TABLE 19.3.3.1 FOR MODERATE EXPOSURE CLA55 Fl. <br /> DIM DIMENSION 50G SLAB ON GRADE DRAWN: JEG <br /> *PROVIDE fc SPECIFIED IN TABLE FOR DURABILITY REQUIREMENTS.2500 PSI CONCRETE MEETS STRENGTH CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS FOR COMPATIBILITY BEFORE PROCEEDING.ANY <br /> REQUIREMENTS,THEREFORE SPECIAL INSPECTION IS NOT REQUIRED. DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE STRUCTURAL ENGINEER BEFORE PROCEEDING. EA EACH STD STANDARD CHECK: JGG <br /> CONTRACTOR-INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE STRUCTURAL ENGINEER FOR ELEV ELEVATION SW SHEAR WALL JOB NO: 25270.003 <br /> REINFORCING STEEL APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION.CHANGES SHOWN ON SHOP DRAWINGS ONLY WILL NOT EXIST EXISTING TOC TOP OF CONCRETE <br /> : <br /> REINFORCING STEEL SHALL BE DEFORMED BILLET STEEL CONFORMING TO ASTM A615,AND SHALL BE GRADE 60(F SATISFY THIS REQUIREMENT.(Fy SATISFY EXPANSION TOS TOP OF STEEL DATE 04/1 1/25 <br /> =60,000 PSI),UNLESS NOTED OTHERWISE.GRADE 60 REINFORCING BARS INDICATED ON DRAWINGS TO BE WELDED DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION.WHERE CONDITIONS ARE NOT FUR FLOOR TOW TOP OF WALL <br /> SHALL CONFORM TO ASTM A706.REINFORCING COMPLYING WITH ASTM A615 MAY BE WELDED IF MATERIAL SPECIFICALLY INDICATED BUT ARE OF A SIMILAR CHARACTER TO DETAILS SHOWN,SIMILAR DETAILS OF <br /> PROPERTY REPORTS INDICATING CONFORMANCE WITH WELDING PROCEDURES SPECIFIED IN AWS D3.4 ARE CONSTRUCTION SHALL BE USED,SUBJECT TO REVIEW AND APPROVAL BY THE STRUCTURAL ENGINEER. FDN FOUNDATION TYP TYPICAL <br /> SUBMITTED. FT N <br /> G FOOTING UNO UNLESS NOTED OTHERWISE Y <br /> WELDED WIRE FABRIC SHALL CONFORM TO ASTM ALES.PROVIDE WELDED WIRE FABRIC IN SHEETS NOT ROLLS.LAP FS FAR SIDE VFV VERIFY U <br /> WELDED WIRE FABRIC 12"ATSIDESAND ENDS. <br /> FH FULL HEIGHT VIF VERIFY IN FIELD Q <br /> REINFORCING STEELSHALL BE DETAILED INCLUDING HOOKS AND BENDS IN ACCORDANCE WITH ACI SP-66 AND ACI GLB GLUE-LAMINATED BEAM VET <br /> VERTICAL <br /> 318,LATEST EDITIONS.UNLESS OTHERWISE NOTED,REINFORCING SPLICE LENGTHS AND DEVELOPMENT LENGTHS <br /> SHALL BE PER SCHEDULE. W <br /> MECHANICAL SPLICING OF REINFORCING BARS,WHERE INDICATED ON THE DRAWINGS,SHALL BE BYAN ICED Q <br /> APPROVED SYSTEM,SHALL DEVELOP 125%OF TH E SPECIFIED YIELD STRENGTH OF THE BAR,AND SHALL BE <br /> INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. <br /> O <br /> REINFORCING SHALL BE PLACED AND ADEQUATELY SUPPORTED PRIOR TO PLACING CONCRETE.WET-SETTING l­_ <br /> EMBEDDED ITEMS IS NOT ALLOWED WITHOUT PRIOR ENGINEER APPROVAL.BARS PARTIALLY EMBEDDED IN 0 <br /> HARDENED CONCRETE SHALL NOT BE FIELD BENT UNLESS 50 DETAILED OR APPROVED BY THE STRUCTURAL <br /> ENGINEER.REFER TO CHAPTER 25 OF ACI 318 FOR OTHER REINFORCING STEEL REQUIREMENTS. <br /> MINIMUM LAPS AND EMBEDMENT N <br /> Q <br /> UNLESS OTHERWISE NOTED,REINFORCING SPLICE LENGTHS AND DEVELOPMENT LENGTHS SHALL BE AS TABULATED W N <br /> BELOW: <br /> w <br /> Fc=2500 P51 W ho <br /> DEVELOPMENT LENGTH LAP SPLICE 11-- 3:: 0 O <br /> BAR TENSION COMPRESSION TENSION COMPRESSION Z N Z <br /> SIZE 00 <br /> TOP BARS BARS ALL BARS TOP BARS BARS ALL BARS U 0 J <br /> #3 24 18 9 30 23 12 CL N Q Q <br /> #4 31 24 12 41 31 15 O _ 0:f <br /> #5 39 30 15 51 39 19 Q <br /> #6 47 36 18 61 47 23 Lo <br /> #7 68 53 21 89 68 27 CL LLI C) <br /> #8 i 78 1 60 1 24 302 78 30 C14O O L.L.( <br /> NOTE: <br /> 2.ALL LENGTH ARE IN INCHES. z > <br /> ALL LAP SPLICES ARE CLASS B. N - Ld N *J <br /> 3."TOP BARS"ARE HORIZONTAL REINFORCEMENT PLACED SUCH THAT MORE THAN 12 INCHES OF <br /> CONCRETE IS CAST IN THE MEMBER BELOW THE BAR. SH EET: <br /> sil <br />