GENERALNOTES <br /> THESE DRAWINGS ARE THE PROPERTY OF H12D,LLC.ANY REPRODUCTIONS MUST BE AUTHORIZED BY THE ARCHITECT AND MUST BEAR THE NAME OF THE ARCHITECT.©COPYRIGHT PROJECT INFORMATION <br /> 2023 BY H21).LLC.THESE DRAWINGS ARE PROTECTED BY FEDERAL AND STATE COPYRIGHT LAWS. <br /> 1.CODES/REGULATIONS: PROJECT OWNER: EVAN BENJAMIR BURTON CONSTRUCTION <br /> -CONSTRUCTION TO CONFORM TO THE 2018 INTERNATIONAL RESIDENTIAL CODE(IRC),WASHINGTON STATE LAWS AND REGULATIONS,CURRENT WASHINGTON STATE RESIDENTIAL 280 SW 43rJ St.BIJo 4 <br /> ENERGY CODE AND VARIOUS CODES IMPOSED BY LOCAL AUTHORITIES. RENTON WA 98057 <br /> -A SEPARATE PERMIT MAY BE REQUIRED FOR PLUMBING,ELECTRICAL,AND/OR MECHANICAL WORK AS APPLICABLE. <br /> -A COPY OF THE APPROVED PERMIT PLANS MUST BE ON THE JOB SITE DURING CONSTRUCTION <br /> 2.CONTRACTOR'S RESPONSIBILITY: PROJECT ARCHITECT: HEIDI HELGESON <br /> -PRIOR TO CONSTRUCTION,THE CONTRACTOR 15 TO VERIFY ALL DIMENSIONS AND STRUCTURAL MEMBER SIZES. PROJECT DESIGNER: H P AIR WELLER <br /> -DO NOT SCALE CONTRACT DOCUMENTS. 22 ARCHITECTURE+DESIGN <br /> -IF ANY DISCREPANCIES IN THE DRAWINGS OF,FROM THE CODES ARE NOTED,ARCHITECT I5 TO SE NOTIFIED IMMEDIATELY. 23020 EDMOND8 WAY,#113 <br /> ALL CHANGES MADE BY THE CONTRACTOR SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO CONSTRUCTION. 206-54PMON S,73 98020 <br /> 206-542-3734 <br /> -THE ARCHITECT SHALL NOT HAVE CONTROL OR CHARGE OF,AND SHALL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS AND METHODS,SAFETY PRECAUTIONS,ACTS OR <br /> OMISSIONS OR PERFORMANCE OF THE CONTRACTOR. STRUCTURAL ENGINEER: DIRK ROG5TAD <br /> _CONTRACTOR SHALL BE RE5PONSIBLE FOR THE PERFORMANCE AND WEATHERPROOFING OF THE ENTIRE BUILDING.ITS COMPONENT EQUIPMENT.AND PARTS. CIS ENGINEERINGALL <br /> -ALL STRUCTURAL SYSTEMS SUCH AS WOOD TRUSSES WHICH ARE TO BE COMPOSED OF COMPONENTS TO BE FIELD ERECTED SHALL BE SUPERVISED 5Y THE SUPPLIER DURING 250 4TH AVE E.SUITE 200 <br /> MANUFACTURING,DELIVERY,HANDLING,STORAGE,AND ERECTION IN ACCORDANCE WITH INSTRUCTIONS PREPARED BY THE SUPPLER. EDMONDS.WA 98020 <br /> -ALL WORK MUST FOLLOW CURRENT KRP RULES AND REQUIREMENTS AS DEFINED BY THE EPA AND THE STATE OF WASHINGTON. (425)778-8500 <br /> -ALL WASTE AND REFUSE CAUSED IN CONNECTION WITH THE WORK SHALL BE REMOVED FROM THE PREMISES AND DISPOSED OF BY THE CONTRACTOR.THE PREMISES SHALL BE <br /> LEFT CLEAR AND CLEAN TO THE SATISFACTION OF THE OWNER. PROJECT DESCRIPTION: INTERIOR REMODEL OF EXISTING <br /> -CONTRACTOR SHALL DESIGN AND INSTALL SHORING AS REQUIRED TO PERFORM WORK ENGINEERING,CONSTRUCTION AND SAFETY OF THE SHORING SHALL BE THE PESPON5151LITY SINGLE FAMILY RE51PENCE J <br /> OF THE CONTRACTOR. PROJECT ADDRESS: 528 MAD15ON 5T W <br /> -FOR ALL NEW CONSTRUCTION OR ADDITIONS DESIGNED WITHIN 1'-d'OF THE HEIGHT LIMIT,THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING WITH THE SURVEYOR TO <br /> VERIFY THE ELEVATION OF THE STRUCTURE AS IT IS BEING BUILT TO VERIFY ANY ELEVATION DISCRPANCIES THROUGHOUT CONSTRUCTION.ELEVATIONS SHOULD BE VERIFIED FOR Q <br /> EACH FLOOR LEVEL PRIOR TO PROCEEDING WITH THE NEXT FLOOR OF FRAMING:TOP OF FOUNDATION,TOP OF SUBFLOOR,TOP PLATE AND RIDGE ELEVATIONS SHOULD BE VERIFIED TAX LOT NUMBER: 00393300001200 <br /> DURING CONSTRUCTION.CONSULT ARCHITECT FOR CLARIFICATION PRIOR TO CONSTRUCTION O <br /> 3'SOILS: LEGAL DESCRIPTION: REV PLY HILLS DIV 5 BLK 000 D-0O-LOT512-13 <br /> -FOUNDATION DESIGN 15 3A5ED ON AN A55UMED AVERAGE SOIL BEARING OF 2,000 PEE OR PER GEOTECHNICAL REPORT.ALL FOOTINGS SHALL BE CAST ON UNDISTURBED FIRM -E 14 LEEHI LS DIV 5 D 2 0 CITY 0 EVERETT <br /> NATURAL 501L OR COMPACTED 501L OF 2,000 PSF BEARING CAPACITY AT LEAST T-6 BELOW LOWEST ADJACENT GRADE,AND FREE OF ORGANIC MATERIALS.FOOTING EXCAVATION M <br /> SHALL BE FREE OF LOOSE SOILS,DEBRIS,AND FREE WATER AT ALL TIMES.THIS OFFICE TAKES D RESPONSIBILITY IN VERIFYING THE ACCURACY OF ENGINEERING DATA SUPPLIED uj O <br /> BY OTHERS. (n � <br /> 4.ATTIC REQUIREMENTS: z co <br /> -APPLY ROOFING IN ACCORDANCE WITH ITC CHAPTER 9.PROVIDE ATTIC VENTILATION AS INDICATED ON DRAWINGS AND AS OUTLINED IN IRC SEC R806. <br /> -THE NET FREE VENTILATING AREA SHALL SE NOT LESS THAN 1/150 OF THE AREA OF THE SPACE VENTILATED.EXCEPT THAT THE AREA MAY BE I/500 PROVIDED AT LEAST 50 LAND USE CODE COMPLIANCE STATISTICS O <br /> PERCENT OF THE REQUIRED VENTILATING AREA IS PROVIDED BY VENTILATION LOCATED IN THE UPPER PORTION OF THE SPACE TO 5E VENTILATED AT LEAST 3 FEET ABOVE EAVE OF <br /> CORNICE VENTS WITH THE BALANCE OF THE REQUIRED VENTILATION PROVIDED BY EAVE OR CORNICE VENTS.QRC SEC R806). ZONE: P <br /> -ATTIC ACCESS:MINIMUM 22"x 30'WITH MINIMUM 30"HEADROOM,UNOBSTRUCTED,READILY ACCESSIBLE OPENING.IRC SEC R607.ACCE55 DOOR5 SHALL BE WEATHERSTRIPPED q <br /> AND INSULATED TO A LEVEL EQUIVALENT TO THE INSULATION ON THE SURROUNDING SURFACES. RED'D SETBACKS: NO CHANGE PROPOSED O Q <br /> -IN ROOMS NOT PROVIDED WITH AN OPERABLE WINDOW OF 15 SQ.FT.OR GREATER,A MECHANICAL VENTILATION SYSTEM CAPABLE OF PROVIDING 5 AIR CHANGES PER HOUR SHALL BE T of <br /> PROVIDED. 1 <br /> -VENT DRYER,BATH FANS.AND RANGES/OVEN5 TO THE OUTSIDE. LOT COVERAGE: NO CHANGES PROPOSED 00 LL <br /> 5.VENTILATION: z N <br /> -VENT FANS SHALL TERMINATE AT THE EXTERIOR OF THE BUILDING PER IRC SECTION M1502.3 AND IMC SECTION 501.3. IMPERVIOUS Lo O <br /> -INSULATE ALL DUCTS OUTSIDE OF CONDITIONED SPACE PER WA STATE ENERGY CODE. SURFACE: NO CHANGES PROPOSED L j f <br /> -KITCHEN RANGE HOODS:RANGE HOODS CAPABLE OF EXHAUSTING MORE THAN 400 CFM REQUIRE MAKE-UP AIR PER IRC M1503G. co <br /> 6.GLAZING, PARKING: 2 EXISTING PARKING 5PACE5 TO REMAIN <br /> TO BE IN COMPLIANCE WITH IRC 5EG R308 AND WASHINGTON STATE SAFETY GLA55 LAW,EXCEPTIONS ARE AS OUTLINED IN IRC DEC R308. Q <br /> GLAZING IN LOCATIONS SUBJECT TO HUMAN IMPACT SUCH AS GLASS IN DOOR5,GLAZING WITHIN 24"ON EITHER SIDE OF A DOOR OPENING,GLAZING CLOSER THAN 18"TO A FLOOR, BUILDING HEIGHT BUILDING HEIGHT LIMIT=25' Q <br /> SNOWER DOORS AND TUB ENCLOSURES SHALL BE WIRE REINFORCED,TEMPERED GLASS,LAMINATED 5AFETY GLASS OR SHATTER RESISTANT PLASTIC. INFORMATION: NO CHANGE PROPOSED <br /> -SLIDING GLASS DOOR5 TO BE SAFETY GLAZING,LAMINATED OR TEMPERED CLASS. C <br /> -SHOWER ENCLOSURES SHALL BE APPROVED WIRE REINFORCED,TEMPERED OR LAMINATED SAFETY GLASS OR SHATTER RESISTANT PLASTIC. Z <br /> GLAZING WITHIN 18"OF FLOOR AND GREATER THAN 113"IN LEAST DIMENSION SHALL COMPLY WITH IMPACT LOADS.SEE PLANS. <br /> -ALL EXTERIOR WALL GLAZING SHALL BE DOUBLE GLAZED.UNLESS NOTED OTHERWISE,AND COMPLY WITH STATE OF WASHINGTON ENERGY CODE. <br /> -EGRE55IN EVERY SLEEPING ROOM SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5.7 SOL FT.THE MINIMUM NET CLEAR OPENING HEIGHT DIMENSION SHALL BE 24",MINIMUM NET ENERGY CREDIT INFORMATION <br /> CLEAR OPENING WIDTH OF 20"AND A FINISHED SILL HEIGHT NOT MORE THAN 44"ABOVE THE FLOOR.IRC SEC R31a <br /> 7,ENERGY, INTERIOR REMODEL ONLY <br /> ALL MATERIALS,WORKMANSHIP AND CONSTRUCTION SHALL CONFORM TO IRC REQUIREMENTS AND THE WASHINGTON STATE ENERGY CODE,LATEST EDITION.VERIFY ALL CONDITIONS ENERGY CREDITS NOT APPLICABLE <br /> BEFORE PROCEEDING WITH WORK. <br /> -APPLICATION AND INSTALLATIONS OF INSULATION AND VAPOR BARRIERS SHALL COMPLY WITH STATE OF WASHINGTON THERMAL INSULATION STANDARDS. <br /> -BUILDING AIR LEAKAGE TESTING.PER SEC 402.4.I5 REQUIRED PRIOR TO FINAL INSPECTION.THE TEST RESULTS SHALL 5E POSTED ON THE RE5IDENTIAL ENERGY COMPLIANCE <br /> CERTIFICATE PRESCRIPTIVE REQUIREMENTS-ALLCLIMATEZONES <br /> -EACH DWELLING UNIT 15 TO HAVE ONE PROGRAMMABLE THERMOSTAT FOR REGULATION OF TEMPERATURE PER SEC 403.1. <br /> -A SIGNED AFFADAVIT DOCUMENTING THE DUCT LEAKAGE TEST RESULTS SHALL 5E PROVIDED TO THE BUILDING INSPECTOR PRIOR TO AN APPROVED FINAL INSPECTION. LOCATION R VALUE U-FACTOR <br /> -DUCT LEAKAGE TEST RESULTS SHALL BE PROVIDED TO THE BUILDING INSPECTOR AND HOMEOWNER PRIOR TO AN APPROVED FINAL INSPECTION. <br /> -MINIMUM 90%OF PERMANENTLY INSTALLED LAMPS IN LIGHTING FIXTURES SHALL BE HIGH EFFICACY LAMPS PER SEC 404.1. FENESTRATION U-FACTOR N/A 0.30 <br /> -WHERE THE PRIMARY HEATING SYSTEM 15 A FORCED-AIR FURNACE.AT LEAST ONE THERMOSTAT PER DWELLING UNIT SHALL BE CAPABLE OF CONTROLLING THE HEATING AND <br /> COOLING SYSTEM ON A DAILY SCHEDULE TO MAINTAIN DIFFERENT TEMPERATURE SET POINTS AT DIFFERENT TIMES OF THE DAY.THE THERMOSTAT SHALL ALLOW FOR,AT A SKYLIGHT U-FACTOR N/A 0.50 <br /> MINIMUM,A 5-2 PROGRAMMABLE SCHEDULE(WEEKDAYS/WEEKENDS)AND BE CAPABLE OF PROVIDING AT LEAST TWO PROGRAMMABLE SETBACKS PER DAY. GLAZED FENESTRATION 5HGC N/A N/A sT18 REGISTERED <br /> a.STAIRS. ARCHITECT <br /> -MINIMUM HEADROOM 6'-8";MINIMUM TREAD 10";MAXIMUM RISER 7 3/4" CEILING 49 0.026 <br /> -HANDRAIL:REQUIRED AT ALL STAIRS WITH MORE THAN 4 RISERS PER IRC 511.7.5.MINIMUM 34"AND MAXIMUM 38"ABOVE TREAD NOSING.OPEN SIDES OF STAIRS MORE THAN 3d' WOOD FRAME WALL 21 IM 0.056 4-- <br /> ABOVE ADJACENT FLOOR.SHALL HAVE HANDRAILS AND GUARDRAILS.HANDRAIL TO BE 11/4"-2"GRO55 5EC11ONAL DIMENSION AND 11/2"AWAY FROM WALL. Heioi micHeue ne�ceson <br /> GUARDRAIL:SHALL BE MIN 36"IN HEIGHT WHERE ADJACENT SURFACE OR GRADE 15 30"OR MORE BELOW.RAILINGS SHALL BE SPACED TO NOT ALLOW THE PASSAGE OF A 4318" MASS WALL R-VALUE 21/21 0.056 STATE OF WASHINGTON <br /> SPHERE PER IRC 312.1. <br /> -INSTALL FIRE BLOCKING AT MID-STRINGER SPAN AND AT WALL ALIGN STRINGER. FLOOR 30 0.029 <br /> LOVER WALLS AND SOFFITS OF USABLE SPACE UNDER STAIR WITH 5/8"TYPE"X"GYPSUM WALLBOARD. BELOW GRADE WALL 10/15/21 INT+TB 0,042 <br /> 9.INSULATION: <br /> -INSULATION TO MEET THE CURRENT WASHINGTON STATE ENERGY CODE REQTS FOR TABLE R402,1.1.TABLE R402.1.3 AND SECTION R402.REFER TO PRESCRIPTIVE TABLE ON SHEET 5LA6 R-VALUE AND DEFTH 10.2 FT WA <br /> 01. <br /> -EXISTING WALL AND FLOOR CAVITIES EXPOSED DURING CONSTRUCTION FOUND UNINSULATED,OR WITH DAMAGED INSULATION(DISCOLORED,WET,DAMAGED,OR <br /> DETERIORATED)SHALL BE FILLED WITH R-15 INSULATION AT 2X4 FRAMING AND WITH R-21 INSULATION AT 2X6 FRAMING.REF SEC R503.1.1-EXCEPTION 2.. LN <br /> -WALLS TO BE INSULATED WITH MINIMUM R-21 INSULATION.BELOW GRADE WALLS TO BE INSULATED WITH MINIMUM R-21 INSULATION,ALLOW FOR THERMAL BREAK BETWEEN FLOOR <br /> SLAB AND BASEMENT WALL UNLESS NOTED OTHERWISE. <br /> -ROOF AND CEILING INSULATED WITH R-49 BLOWI+IN AT FLAT CEILINGS AND IR38 H.D.GATT AT VAULTED AREAS UNLESS NOTED OTHERWISE. SHEET INDEX <br /> -ROOF:ALLOW FOR A MINIMUM 1"CLEAR BETWEEN TOP OF INSULATION AND BOTTOM OF SHEATHING FOR VENTING UNLESS NOTED OTHERWISE. <br /> -VENTING IS REQUIRED IN EACH JOIST SPACE.WHERE CONTINUOUS VENTING WITH A JOIST SPACE 15 INTERRUPTED BY A HEADER(FOP,EXAMPLE AT A SKYLIGHT OR HIP),PROVIDE(2) 01 PROJECT INFORMATION,VICINITY MAP,GENERAL NOTES,A5-BUILT PLANS <br /> 11/2"VENTING HOLES AT THE TOP OF THE RAFTER AT THE HEADER TO ALLOW FOR CONTINUOUS THPU-VENTING INTO THE NEXT JOIST SPACE UNLESS NOTED OTHERWISE. 02 SITE PLAN <br /> -FLOORS:INSULATED WITH R-30 GATT INSULATION OVER UNHEATED SPACE UNLESS NOTED OTHERWISE. A1.0 MAIN FLOOR.DEMOLITION PLAN AND MAIN FLOOR PLAN <br /> -SLAD <br /> -ONGRADE:PROVIDE EXTRUDED RIGID CLOSED CELL R-10 INSULATION.INSULATION TO PROVIDE THERMAL BREAK BETWEEN SLAB AND FOOTING AND RUN FROM THE TOP OF THE A2.0 EXTERIOR ELEVATIONS <br /> SLAB TO THE BOTTOM OF THE FOOTING.INSULATION MAY BE INTERRUPTED FOR 6"EVERY 2'{Y'TO ALLOW FOR DOWELING TO TIE SLAB AND FOOTING TOGETHER.UNLESS NOTED A3.0 BUILDING SECTIONS <br /> OTHERWISE. A5.0 TYR.DETAILS <br /> 10.GARAGE SEPARATION: 51.1 GENERAL STRUCTURAL NOTES <br /> -REQUIRE51/2"GW5 ON THE GARAGE SIDE.5/8"TYPE'X'GW5 WHERE THERE 15 LIVING SPACE ABOVE.SUPPORTING COLUMNS,WALLS AND BEAMS USE 1/2"GAR PER IRC R302.6 52.1 PARTIAL FOUNDATION,FLOOR AND ROOF FRAMING PLANS DETAILS <br /> -OPENINGS INTO A GARAGE:OPENINGS INTO A GARAGE SHALL HAVE A SOLID WOOD OR HONEYCOMB-CORE STEEL DOOR NOT LE55 THAN 1-3/8"THICK,OR 20-MINUTE FIRE RATING. <br /> DOOR5 SHALL BE EQUIPPED WITH A SELF-CLOSING DEVICE PER IRC R302.5.1. <br /> 11.VAPOR BARRIERS: <br /> AN APPROVED VAPOR BARRIER SHALL BE INSTALLED AT EXTERIOR WALLS AND AT ALL ROOF DECKS,BELOW ENCLOSED JOIST SPACES WHERE CEILING FIN15HE5 ARE DIRECTLY <br /> INSTAL <br /> ANY <br /> LATION.T45 VAPOR <br /> 1 DATIONS FF INSULATION AND VAPOR BARRIER5 SHALL COMPLY WITH STATE OF WAASHINGTON THERMAL R WALL OR CEILING SURFACES WHICH RECEIVE UIEF MAY DE I�MATION STPONENT AF THE NDARDS.ANDARDSINSULATION MATERIAL. <br /> APPLICATION AND INSTALL O LH 2 D <br /> 12.FIRE SAFETY: A R C H I T E CT U R E <br /> -SMOKE ALARMS/DETECTORS(SE.):SMOKE ALARMS/DETECTORS SHALL BE INSTALLED IN ALL SLEEPING ROOMS,IN THE AREA OUTSIDE THE SLEEPING ROOM AND IN OTHER + <br /> LOCATIONS PER NO R314.POWER SOURCE AND INTERCONNECTION PER IRC. D E S G N <br /> 0 + -CARBON MONOXIDE DETECTORS(OM.D.):SHALL HAVE AN APPROVED CARBON MONOXIDE ALARM INSTALLED OUTSIDE OF EACH SLEEPING AREA IN DWELLING UNITS AND IN EACH LEVEL <br /> IN ACCORDANCE WITH THE MANUFACTURER'S REQUIREMENTS PER IRC315.SINGLE STATION CARBON MONOXIDE ALARMS SHALL BE LISTED AS COMPLYING WITH UL2034 AND SHALL <br /> DE INSTALLED IN ACCORDANCE WITH THIS CODE.NFPA 720-2012 AND THE MANUFACTURER'S I1\15TALLATION INSTRUCTIONS. <br /> �. -CARBON MONOXIDE DETECTION SYSTEMS PER IRC 315.2 THAT INCLUDE CAR50N MONOXIDE DETECTORS AND AUDIBLE NOTIFICATION APPLIANCES,INSTALLED AND MAINTAINED IN <br /> ACCORDANCE WITH THIS SECTION FOR CARBON MONOXIDE ALARMS AND NFPA 720-2012.SHALL BE PERMITTED.THE CARBON MONOXIDE DETECTORS SHALL BE LISTED AS COMPLYING 23020 EDMONDS WAY, #113 <br /> WITH UL 2075.WHERE A HOUSEHOLD CARBON MONOXIDE DETECTION SYSTEM 15 INSTALLED,IT SHALL BECOME A PERMANENT FIXTURE OF THE OCCUPANCY. E D M O N D S,WA 98020 <br /> 13.CERTIFICATE a TESTING <br /> W + I� -A PERMANENT CERTIFICATE SHALL BE COMPLETED AND POSTED ON OR WITHIN THREE FEET OF THE ELECTRICAL DISTRIBUTON PANEL BY THE BUILDER OR REGISTERED DESIGN P.2 0 6. 5 4 2 . 3 7 3 4 <br /> L �I PROFESSIONAL.THE GERTIFIGA FE SHALL BE COMPLETED BY THE BUILDER OF,REGISTERED DESIGN PROFESSIONAL AND SHALL NOT COVER OR OF35TPUCT THE VISIBILITY OF THE W W W.h 2 d a r c h i to ct s.c om <br /> CIRCUIT DIRECTORY LABEL,SERVICE DISCONNECT LABEL,OR OTHER REQUIRED LABELS.THE CERTIFICATE SHALL LIST THE PREDOMINANT R-VALUES OF INSULATION INSTALLED IN OR ON <br /> CEILING/ROOF WALL5,FOUNDATION(SLAB,BELOW-GRADE WALL,AND/OR FLOOR)AND DUCTS OUTSIDE CONDITIONED SPACES;U-FACTORS FOR FENESTRATION AND THE RESULTS <br /> FROM ANY REQUIRED DUCT SYSTEM AND BUILDING ENVELOPE AIR LEAKAGE TESTING DONE ON THE BUILDING.WHERE THERE 15 MORE THAN ONE VALUE FOR EACH COMPONENT,THE <br /> CERTIFICATE SHALL LI5T THE VALUE COVERING THE LARGEST AREA.THE GERTRIFIGATE SHALL LIST THE TYPES OF EFFICIENCIES OF HEATING,COOLING,AND SERVICE WATER HEATING <br /> p fl EQUIPMENT.-THE BUILDING OR DWELLING UNIT SHALL 5E TESTED AND VERIFIED AS HAVING AN AIR LEAKAGE RATE OF NOT EXCEEDING 5 AIR CHANGES PER HOUR.TESTING SHALL BE CONDUCTED MADISON <br /> WITH A BLOWER DOOR AT A PRESSURE OF 0.2 INCHES W.G.(50 PASCALS).WHERE REQUIRED BY THE CODE OFFICIAL.TESTING SHALL BE CONDUCTED BY AN APPROVED THIRD PARTY. MORGAN DATE: 12/22I2023 <br /> A WRITTEN REPORT OF THE RESULTS OF THE TEST SHALL BE SIGNED BY THE PARTY CONDUCTING THE TEST AND PROVIDED TO THE CODE OFFICIAL.TESTING SHALL BE PERFORMED PARK MAP15ON ST <br /> AT ANY TIME AFTER CREATION OF ALL PENETRATIONS OF THE BUILDING THERMAL ENVELOPE. <br /> 14.LIGHTING EQUIPMENT SITE <br /> -NOT LESS THAN 90 PERCENT OF LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL BE HIGH-EFFICACY LAMPS y BEVERLY <br /> -FUEL GAS LIGHTING 5YSTEM5 SHALL NOT HAVE CONTINUOUSLY BURNING PILOT LIGHTS LAKE <br /> 0 <br /> 151575E PERMIT SET <br /> � m <br /> �C R� <br /> PROJECT INFORMATION, <br /> VICINITY MAP,GENERAL <br /> NOTES,AS-BUILT PLANS <br /> HWY 526 <br /> h <br /> N <br /> AS BUILT- MAIN FLOOR m N <br /> SCALE:118'= Ta VICINITY MAP NTS <br /> 01 <br />