Laserfiche WebLink
5/7/2021 2019SWMMWW-BMP Maintenance Tables <br /> Maintenance Defect Condition When Results Expected When <br /> Component Maintenance is Needed Maintenance is Performed <br /> See Table V-A.3: Maintenance See Table V-A.3: Maintenance See Table V-A.3: Maintenance <br /> Manhole Standards - Closed Detention Standards - Closed Detention Standards - Closed Detention <br /> Systems (Tanks/Vaults) Systems (Tanks/Vaults) Systems (Tanks/Vaults) <br /> Catch Basin See Table V-A.5: Maintenance See Table V-A.5: Maintenance See Table V-A.5: Maintenance <br /> Standards - Catch Basins Standards- Catch Basins Standards - Catch Basins <br /> Table V-A.5: Maintenance Standards - Catch Basins <br /> Results Expected <br /> Maintenance Defect Conditions When Maintenance is Needed When <br /> Component Maintenance is <br /> performed <br /> General Trash or debris which is located immediately in front of the No Trash or debris <br /> catch basin opening or is blocking inletting capacity of the located <br /> basin by more than 10% immediately in front <br /> of catch basin or <br /> Trash or debris (in the basin)that exceeds 60 percent of the on grate opening. <br /> sump depth as measured from the bottom of basin to invert of <br /> the lowest pipe into or out of the basin, but in no case less trash or debris <br /> in <br /> Trash & than a minimum of six inches clearance from the debris n the catch basin. <br /> Debris surface to the invert of the lowest pipe. Inlet and outlet <br /> Trash or debris in any inlet or outlet pipe blocking more than pipes free of trash <br /> 1/3 of its height. or debris. <br /> Dead animals or vegetation that could generate odors that No dead animals or <br /> could cause complaints or dangerous gases (e.g., methane). vegetation present <br /> within the catch <br /> basin. <br /> Sediment(in the basin)that exceeds 60 percent of the sump <br /> depth as measured from the bottom of basin to invert of the <br /> lowest pipe into or out of the basin, but in no case less than a No sediment in the <br /> Sediment minimum of 6 inches clearance from the sediment surface to catch basin <br /> the invert of the lowest pipe. <br /> Top slab has holes larger than 2 square inches or cracks wider Top slab is free of <br /> i l i i t k t t i t I h 1/4 in <br /> ch.nc . (Intent o make sure no material runnn holes and cracks. <br /> Structure than ( g <br /> Damage to into basin). Frame is sitting <br /> Frame and/or Frame not sitting flush on top slab, i.e., separation of more flush on the riser <br /> Top Slab than 3/4 inch of the frame from the top slab. Frame not rings or top slab <br /> securely attached and firmly <br /> attached. <br /> Basin replaced or <br /> Fractures or Maintenance person judges that structure is unsound. repaired to design <br /> Cracks in standards. <br /> Grout fillet has separated or cracked wider than 1/2 inch and <br /> Basin Walls/ longer than 1 foot at the joint of any inlet/outlet pipe or any Pipe is regrouted <br /> Bottom evidence of soil particles entering catch basin through cracks. and secure at <br /> basin wall. <br /> https://fortress.wa.gov/ecy/ershare/wq/Permits/Flare/2019SWMMWW/2019SWMMWW.htm#TopicsNolumeV/App_BMPMaintenanceTables.htm%3FT... 3/6 <br />