Laserfiche WebLink
1. Complete the data validation report. <br /> 2. Prepare a TEER summary, including a testing summary and conclusions <br /> compared with the supplier's performance claims. <br /> 3. Provide a recommendation of the appropriate technology use level. <br /> 4. Work with Ecology to post recommend relevant information on Ecology's <br /> website. <br /> 5. Provide additional testing recommendations, if needed." <br /> 6. This report, authored by Dr. Gary Minton, Ph. D., P.E., Resource Planning <br /> Associates, satisfies the Ecology requirement. <br /> • (Public) "Performance of the Stormwater Management StormFilter Relative to the <br /> Washington State Department of Ecology Performance Goals for Basic <br /> Treatment," is a summary of StormFilter performance that strictly adheres to the <br /> criteria listed in the Guidance for Evaluating Emerging Stormwater Treatment <br /> Technologies, Technology Assessment Protocol—Ecology(TAPE). <br /> • "Heritage Marketplace Field Evaluation: Stormwater Management StormFilter <br /> with ZPGTM Media," is a report showing all of the information collected at Site A <br /> as stated in the SMI Quality Assurance Project Plan (QAPP). This document <br /> contains detailed information regarding each storm event collected at this site, and <br /> it provided a detailed overview of the data and project. <br /> • "Lake Stevens Field Evaluation: Stormwater Management StormFilter with <br /> ZPGTM Media," is a report that corresponds to Site E as stated in the SMI QAPP. <br /> This document contains detailed information regarding each storm collected at <br /> this site, and includes a detailed overview of the data and project. <br /> • (Public) "Evaluation of the Stormwater Management StormFilter for the removal <br /> of SIL-CO-SIL 106, a standardized silica product: ZPGTM at 7.5 GPM" is a report <br /> that describes laboratory testing at full design flow. <br /> • "Factors Other Than Treatment Performance." <br /> • 'State of Washington Installations." <br /> • "Peak Diversion StormFilter"is a technical document demonstrating the Peak <br /> Diversion StormFilter system complies with the Stormwater Management Manual <br /> for Western Washington Volume V Section 4.5.1. <br /> Above-listed documents noted as "public" are available by contacting CONTECH. <br /> Applicant's Use Level Request: <br /> That Ecology grant a General Use Level Designation for Basic Treatment for the <br /> StormFilter using ZPGTM media(zeolite/perlite/granular activated carbon) at a hydraulic <br /> loading rate of 1 gpm/ft2 of media surface area in accordance with Ecology's 2011 <br /> Technical Guidance Manual for Evaluating Emerging Stormwater Treatment <br /> Technologies Technology Assessment Protocol—Ecology (TAPE). <br /> CONTECH-StormFilter®GULD Maintenance Update(November 2012) Page 15 <br />