My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1717 13TH ST MEDICAL CENTER 2025-09-29
>
Address Records
>
13TH ST
>
1717
>
MEDICAL CENTER
>
1717 13TH ST MEDICAL CENTER 2025-09-29
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/29/2025 1:16:37 PM
Creation date
9/5/2025 3:04:22 PM
Metadata
Fields
Template:
Address Document
Street Name
13TH ST
Street Number
1717
Tenant Name
MEDICAL CENTER
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 2 1 3 1 4 1 5 1 6 1 7 181 9 1 10 11 <br /> Item Electrical Layout Item List GENERAL NOTES: <br /> BASIC SYSTEM 1. THE INFORMATION ON THIS SHEET HAS BEEN TAKEN FROM GE SITE SPECIFIC PLANS <br /> 1 Main disconnect panel (MDP) AND EDITED.CONTRACTOR SHALL OBTAIN A COPY OF THE GE SITE SPECIFIC DRAWINGS tg b architects <br /> 2 Suitable bushings&lock nuts(Gantry) PRIOR TO CONSTRUCTION.COORDINATE ANY DISCREPANCIES WITH ENGINEER PRIOR TO <br /> Y <br /> 3 Suitable bushings&lack nuts(PDU) <br /> 4 Suitable bushings&lock nuts(Console) 2. OBTAIN A COPY AND REVIEW OF THE GE PRE—INSTALL MANUAL PRIOR TO THE START OF <br /> CONSTRUCTION. <br /> 5 Suitable bushings&lock nuts(PARC) t 425.778.1530 21911 76th Ave W.Ste 210 <br /> 6 Cable inlet above ceiling(Express Camera) 3. COORDINATE ALL WORK WITH GE TECHNICIAN AND OTHER TRADES PRIOR TO THE START f 425.774.7803 Edmonds WA 98026 <br /> OF INSTALLATION. <br /> 7 3"conduit below floor for water lines info@tgbarchitecls.com <br /> 8 2 1/2"conduit below floor 4. REMOVE ANY EXISTING CONDUITS THAT CANNOT BE REUSED. www.tgbarchitects.com <br /> 9 3 1/2"conduit below floor <br /> 10 1 1/2"conduit below floor <br /> 11 4"x 4"x 4"box(Partial UPS) <br /> 12 4"x 4"x 4"box(Express Camera) <br /> 13 12"x 16"x 6"box(Power Distribution Unit) <br /> V144"x 4"x 4"box(RCK—AVIMOS Camera)typically®6"below finished ceiling4"x 4"x 4"box(RCK—AVIMOS Console)® 1'-6"above finished floor FLAG NOTES: EVIDENCE <br /> Suitable bushings&lock nuts(Chiller) BASED <br /> 1"conduit below floor 1� DISCONNECT AND DEMOLISH EXISTING MAIN DISCONNECT AND MAINTAIN BD DESIGN <br /> CIRCUITING/WIRING FOR RECONNECTION.REFER TO FLAG NOTES 2 AND 3(THIS SHEET) SERVICES <br /> Electrical Outlet Legend FOR ADDITIONAL INFORMATION. <br /> ITEM QTY cuotraaor:avp0.aa�amarall�ditw��me:amnew,i:e:veueea. CONNECT NEW MAIN DISCONNECT PANEL TO EXISTING CIRCUIT. <br /> Height,No fio determinedbvlo�almdesunlesaoth,mw p,Ifi,d. <br /> Z System emergency off(SEO) ® RECONNECT EXISTING FEEDER AND REUSE EXISTING CONDUIT. EXTEND AS REQUIRED. <br /> 0 X—Ray room warning light control panel B�::- DISCONNECT EXISTING EPO CIRCUIT® X—Ray ON lamp (L1) — 24V NOTE 5(THIS SHE O MANTAN R RECONNECTION.REFER TO FLAG <br /> ET)FOR ADDITIONAL INFORMATION. <br /> © RECONNECT EXISTING EPO CIRCUIT. EXTEND CONDUIT AND WIRING AS REQUIRED. <br /> © PROVIDE(3)#3& 1#1/OG AWG AND NEW CONDUIT AS INDICATED.EXTEND TO NEW PDU. <br /> 7 DISCONNECT EXISTING X—RAY ON CONTROLLER AND LIGHT AND MAINTAIN CIRCUIT/WIRING by OF W' t'gG <br /> FOR RECONNECTION.REFER TO FLAG NOTE 8,THIS SHEET,FOR ADDITIONAL <br /> Additional Conduit Runs INFORMATION. y <br /> (Contractor Supplied and Installed) ® RECONNECT EXISTING X—RAY ON CONTROLLER AND LIGHT TO NEW CT SYSTEM.EXTEND <br /> From To Qt Size AS REQUIRED. 51724 <br /> (Bubble#/Item y) (Bubble#/Item) In. IOfT3A1L <br /> 3 Phase Power 1 Main Disconnect Panel 1 — © 0710812024 <br /> Emergency Off 1 — <br /> 1 Main Disconnect Panel <br /> 13 Power Distribution Unit 1 1-1/2 <br /> m <br /> 13 Power Distribution Unit Door Switch 1 1/2 <br /> 1 — <br /> Warning Light Warning Light Control 1 — �® <br /> 1 Phase Power 1 — 4® <br /> 6 Express Camera 12 Operator's Console 1 1 1/2 <br /> 1 Main Disconnect Panel 1 1 1/4 <br /> 11 Partial UPS <br /> 13 Power Distribution Unit 1 2 <br /> 15 RCK—AVIMOS Console 14 RCK—AVIMOS Camera(x3) 1 1 <br /> 5.15.2 (6) l f l <br /> PROVIDENCE <br /> COLBY PET CT <br /> C.2 17 <br /> 14 <br /> 8 1717 13th St <br /> I----- I Everett,WA98201 <br /> _ I <br /> 17 9 HOLD 21 I HOLDS <br /> 1Q L3 13 11 INJECT G a6 ftr — INJECT o uZ NEY Lz OH 8 <br /> V = _ CONSTRUCTION <br /> I— <br /> DOCUMENTS <br /> s s z P UVATE <br /> stnFF I <br /> 16 sRE�H J EA J <br /> m PET CT <br /> ELECTRICAL <br /> 6 <br /> RR O_AOA 5 2fia„ N D RACEWAY PLAN <br /> 14 2aa a <br /> PET CT ISSUANCE <br /> 20o a2 No. Description Dab.a <br /> PERMIT SET 07/0812024 <br /> CORRIDOR <br /> ® \ \ <br /> 14 � 12 OLD 1 <br /> INJE 00,13 NEY <br /> 00.13 <br /> DN 15 <br /> 4 PEKE CANCER <br /> CTR DIR. <br /> 2 1 <br /> UP � 4 <br /> z -a [MO coN ROL �1fy �y <br /> f'11pU11¶IIIIaI 1 <br /> WAIT NC_, <br /> 200.14 <br /> m _ <br /> 66 tj M <br /> QENLARGED SECOND FLOOR PET CT RACEWAY PLAN 0 2' 4' 8' <br /> SCALE:1/4" = 1'-0" E1.00-PET N 1 PLOTTED PROJECT INFORMATION <br /> PROJECT NUMBER: B24-1032 <br /> PROJECT LEAD: JGG <br /> DRAWN BY: CMB <br /> a <br /> SHEET NO <br /> E1 .22-PET <br /> 1 2 3 4 5 6 7 8 9 10 11 <br />
The URL can be used to link to this page
Your browser does not support the video tag.