Laserfiche WebLink
GENERAL NOTES: <br /> NEW EQUIPMENT SCHEDULE 1. ALL ELECTRICAL WORK AND MATERIALS ARE TO COMPLY WITH LATEST REQUIREMENTS OF ALL <br /> APPLICABLE CITY,COUNTY,AND STATE CODES AS WELL AS NATIONAL ELECTRICAL CODE AS <br /> ADOPTED AND AMENDED BY LOCAL AUTHORITY HAVING JURISDICTION. <br /> NEW EQUIPMENT COORDINATION SCHEDULE 2. ALL EXISTING ELECTRICAL INFRASTRUCTURE AND DISTRIBUTION EQUIPMENT IS TO REMAIN BW <br /> EVIDENCE <br /> Equipment ID D.,Nptian Voltage HP Amps Load(KVA) Panel Circuit OCP Conduit Conductor Size Comments UNLESS OTHERWISE NOTED. BASED <br /> Amps 3. ALL EXISTING INFRASTRUCTURE SHOWN HEREIN IS BASED ON RECORD DRAWINGS AND HAS DESIGN <br /> MECHANICALLOAD NOT BEEN VERIFIED IN FULL ELECTRICAL CONTRACTOR SHALL FIELD VERIFY ALL EXISTING <br /> FRYERUNIT FRYER 208Vl3ph 96 34.56 PANEL K3 18,20,22 100 1.112" 3#1&#SG MOCP=100A INFORMATION RELEVANT FOR SCOPE OF THIS PROJECT. SERVICES <br /> 4. ALL WIRING IS COPPER UNLESS OTHERWISE NOTED. <br /> 5. ALL WORK SHALL BE DONE ON DE-ENERGIZED EQUIPMENT ONLY AND ALL LOTO PROCEDURES <br /> SHALL BE FOLLOWED AS REQUIRED PER NEC AND OSHA. CONSULTANTS <br /> PANEL SCHEDULES <br /> PANEL SCHEDULE DISTRIBUTIONBOARD SDB1 PANEL SCHEDULE PNL K3(NEW) FLAG NOTES: <br /> 208 n 1zo VOLTS NORMAL POWER BUS RATING: e00 AMPS LocanoN. SPEC PANEL yaTH: vEs No 08 r -z0 sOra NORMAL POWER BUS RATING 4o0n AMPS Locnnox: KITCHEN IN SPEC PANEL wxH: vas No � DEMOLISH EXISTING PANEL AND FEEDER BACK TO SOURCE.REPLACE CIRCUIT BREAKER WITH A <br /> - NEW 400A BREAKER AS INDICATED PER NOTE 2.MIGRATE EXISTING LOADS A NEW PANEL K3. VECA <br /> 3 PHASE PNL MFR.: MAIN BKR'. MOB MOONING: SURFACE FEED LUGS X S-P-A3E PNL.MFR: _ MAIN BKR: MOB INmE<I MOUNTING: SURFACE FEED THIN LUGS _ % <br /> 4 WIRE CAT.NO: NF418LIC AUTO RATING: 10,628 AID SYM FED FROM', DOUBLE LUGS X 4WIRE CAT,NO_ _ A,I.C.RATING: 10,600 AICSVM FEDFROM: SIDE DCUBLELUGS _ _ % � PROVIDE NEW 400A CIRCUIT BREAKER AND FEEDER TO CONNECT TO NEW PANEL K3. <br /> 200%NEUTRAL X 200%NEUTRAL X ELECTRIC&TECHNOLOGIES <br /> cr CIRCUIT DESCRIPTION LOADLOCAnON CODE LOAD BKR PH BKR LOAD CODE CIRCUIT DESCRIPTION LOADLCCAnON CKT GKT CIRCUITDESCRIPnON LOAD LOCATON CODE LOAD BKR PH BKR LOAD CODE CIRCUIiIDESCRIPTION LOADLOCATON CKT INSTALL NEW 400A PANEL K3.REFER TO PANEL SCHEDULES FOR ADDITIONAL INFORMATION <br /> AND BREAKER CONFIGURATION. <br /> No, (ROOM NO.IGRID) (kVA) AMPS AMPS (kVA;i (ROOMNO.IGMD) NO NO, (ROOMNO.IGRID) (kVA) AMPS AMPS (AVA) )ROOM NO.IGRID) N0. <br /> 1 -A- 2 _L DOUGHSPREADER ROOM160 INOieal ISO A- 22 2 ® LOAD ADDED TO UPSTREAM DISTRIBUTION IS UNDER 5%OF THE SYSTEM CAPACITY AS <br /> 3 PANELK7 KITCHEN AREA 2250 4H 2250 PANELIPI 4 3 INDTE31 .B NO (NOTE3) "LINUNDERHOOD41 ROOM 165 TOP DECK 4 ALLOWED PER WAC 296-468-900(3)(V)(D). <br /> 5 L 6 5 SPARE 2V1 f. INOTE31 6 <br /> 7 -A- 0 7 CORD DROPS ROOM 165 INOTE31 MI A. DOrESI 0 "AL/, <br /> 9 PANELIP3 4W3 43 2250 PANELK7 10 9 CORD DROPS ROOM 165 MOTE31 2N7 B 30D UOTE3I OVEN UNDERHOOD p2 ROOM 165 BTM DEC( 10 �1"p4 w rLO <br /> 11 O 12 11 SPARE 2011 -c (NOTE3) 12 FO//II11IIII Ao <br /> 13 -A 11.52 14 13 SPARE 2V1 �A- 11.62 H 14 r 0 1 <br /> 15 PANELIP2 225'9 .& 4003 11.57 PANEL K3(NOTE 2) KITCHEN AREA 16 15 SPARE E B 913 11.52 H FRYER ROOM 160 16 V <br /> 11 G 11.52 IB 17 SPARE Nil -G 17.52 H 18 <br /> 19 SPACE A 20 19 SPARE 2011 : SPARE 20 �15 172. <br /> 21 SPACE YA 4} NO TVSS 22 21 SPARE 2011 B- SPARE 2P IOAAG T'"1 1/P4/P5 <br /> 23 SPACE .0 23 SPARE 20H -G SPARE 24 <br /> CODES: CONNECTEDLOAD CALCULATED DEMAND LOAD 1 THIS IS AN EXISTING SWITCHBOARD TO REMAIN.ALL OCPD 25 SPARE 20'1 A- SPARE 26 <br /> H =NVACLOAD$ 34.56 kVA 34.56 kVA (100%) ARE EXISTING UNLESS OTHERWISE NOTED. 27 SPARE 2017 B. SPARE 26 PANEL K3 ADDITION <br /> K =KITCHEN EQUIPMENT 0.00 kVA ON kVA (100%) NEW CIRCUIT DESCRIPTIONS ARE SHOWN IN BOLD. 29 SPARE SPACE 30 <br /> L =LIGHTING LOADS 0.00 kVA 0.00 kVA (125%) ONLY NEW LOAD IS LISTED ON BREAKERS.EXISTING LOAD IS 31 SPACE A SPACE 32 <br /> LM =LARGEST SINGLE MOTOR 0.00 kVA 0.00 kVA (125%) INCLUDED UNDER MAXIMUM DEMAND METERED DATA. 33 SPACE B- SPACE 34 /+ (� <br /> M =OTHER MOTOR LOADS 0.00 kVA ON kVA (100%) 2 REPIACEEXISTNOIOOA WITH NEW 400A BREAKER TOFEED 35 SPACE -C- SPACE 36 SNO-ISLE TECH SKILLS CENTER <br /> NC =NON COINCIDENTAL LOADS 0.00 kVA ON kVA (0%) NEW PANELK7. 37 SPACE A- SPACE 38 EVERETT,WA 98221 <br /> R =GENERAL USE RECEPTACLES 0.00 kVA 0.00 kVA (50%AONA) 39 SPACE B SPACE 40 <br /> S =DEDICATED RECEPTACLES 0.00 kVA 0.00 kVA (100%) 41 SPACE -G SPACE 42 <br /> Z =MISC.OR APPLIANCES 0.00 kVA ON kVA (100%) CODES: CONNECTEDLOAD CALCULATED DEMAND LOAD 1 THIS ISA NEWPANELBOARD <br /> MD =MAXIMUM DEMAND METERED DATA 85.00 kVA 106.25 kVA (125%) H HVAC LOADS 34,56 kVA 34.56 kVA 000%) 2 MAXIMUM DEMAND DATAWAS COLLECTED FROM EXISTING PANEL THAT OWNER <br /> TOTALS: 119.56 kVA 140,81 kVA K KITCHEN EQUIPMENT 000 kVA 0.00 kVA (100%) IS DEMOLISHED AND ALL ITS LOADS SHALL BE MOVED TO THIS PANEL VECA ELECTRIC <br /> 331.9 AMPS 391 AMPS L =LIGHTING LOADS 000 kVA 0.00 kVA (125%) 3 INCLUDED IN METERING DATA FOR DEMOLISHED PANEL <br /> LM =LARGEST SINGLE MOTOR 000 kVA 0.00 kVA (125%) 4 PROVIDE MCB WITH SHUNT TRIP. 11404 MOORAGE WAY <br /> M =OTHER MOTOR LOADS 000 kVA 0.00 MIA (IN%) LA CONNER,INA 98257 <br /> INC =NONCOINCIDENTAL LOADS 000 kVA 0.00 kVA (0%) <br /> R =GENERAL USE RECEPTACLES 000 kVA 0.00 kVA (5D%>10kVA) <br /> S =DEDICATED RECEPTACLES 000 kVA 0.00 kVA (100%) <br /> Z =MIBC.ORAPPL4WCES 000 kVA 0.00 kVA (IN%) <br /> MD =MAXIMUM DEMAND METERED DATA 1590 kVA 19.88 kVA (125%) INOTE2) <br /> TOTALS: 50.46 kVA 54.44 kVA <br /> 140.1 AMPS 151 AMPS <br /> ®LOAD CALCULATIONS <br /> SWBD SDBI 208V,BOOR kVA AMPS@ <br /> 208V <br /> SDB1-30-DAY METER DATA DATED 919324 85.0 236.0 <br /> + +25%PER NEC 220.87 21.3 59.0 <br /> ADDED PROJECT LOAD 34.6 95.9 <br /> TOTALLOAD 140.8 390.9 <br /> PNL K3 208V,40M kVA AMPS@ <br /> 208V <br /> PNL K3-30-DAY METER DATA DATED 91912024 15.9 44.0 <br /> + +25%PER NEC 220.87 4.0 11.0 <br /> ADDED PROJECT LOAD 34.6 95.9 <br /> TOTALLOAD 544 150.9 <br /> SUB DISTRIBUTION BOARD <br /> MAIN DISTRIBUTION BOARD ' 2-1/2`C,4#4/0 CU <br /> 'MD81' 800A,208/12012O V,30,4W 4`C,4#600MCM CU <br /> 1000A,480/277V,30,4W 10628 AIC <br /> 3P-400A <br /> MAIN DISTRIBUTION 3P-225A <br /> SWITCHBOARD'MDB2' 3 <br /> 3000A,480/277V,30,4W O 3P-225ADM <br /> PANEL PANEL PANEL PANEL PANEL 3P-225A <br /> 1HL1 1HM1 1HM1 KH X2 PANEL PANEL PANEL PANEL PANEL PAN0. PANEL PANEL PANEL PANEL PANEL PANEL <br /> 3P-25A 1P1 1P1 1C1 1C1 K1 K1 1P2 1P3 iP3T 1C2 1C2 <br /> 1-1/2-C, SEC 1 SEC 2 K3 <br /> TO EXISTING PANELS 4#1 CU SEC 1 SEC 2 SEC 1 SEC 2 SEC 1 SEC 2 22, SEC 1 SEC 2 SEC 1 SEC ' 400A <br /> 3000A = 225A 225A 225A 225A 225A 225A 400A 400A 1GOA 10011 <br /> 3P <br /> 3P-100A 1-1/2`C, 4#1, 1#4G CU <br /> O TO EXISTING PANELS 3P- A 4`C,4#600 CU 3P-30A <br /> 800A <br /> 3P-1000A 3P-225A 2-1/2"C, 4#4/0 CU 2-1/2"C, 4#4/0, 1#4/OG CU <br /> 3P-400A TRANSFORMER T1 2`C, 4#3/0 CU <br /> 3P-600AOOA 3P_0A 2-1/2"C,4#4/0 CU 300 KVA " <br /> 3P-150A 3P-OOA 48OV-208Y/120V 3P-�1 <br /> 3P-25A PARE 4`C,4#600MCM CU 30 4W 2 <br /> 3P-200A SPARE II SPACE <br /> SPACE <br /> SPACE 2 2`C, 4#3/0, 1#3G CU <br /> 1J1 "Lju., <br /> TO SERVICE _ BUILDING 1 <br /> TRANSFORMER <br /> (3) PARALLEL RUNS OF 4`C (2) PARALLEL RUNS <br /> #400 MCM CU EACH AND OF 4`C, 4#600 <br /> GROUND TO EXISTING GENERATOR MCM CU <br /> PANEL'X'IN BUILDING 2 <br /> EXISTING TO EXISTING BUILDING 3 2`C,4#3 CU <br /> PANEL I <br /> 480/208V 1/24/25 PERMIT SET <br /> 200A <br /> MARK DATE DESCRIPTION <br /> PROJECTNO:B25-1001 <br /> EXISTING XFMR CAD DWG FILE:E7.00-DWO <br /> 112 KVA DRAWN BY:NS <br /> 48OV-20BY/120V <br /> 30 4W CHKD BY: H <br /> EXISTING EXISTING <br /> PANEL J PAN0.E DATE:01n4l2025 <br /> 208/120V 208/120V <br /> PF-=-400A 225A SHEET TITLE <br /> ONE-LINE DIAGRAM, PANEL <br /> SCHEDULES,AND LOAD <br /> CL <br /> 2 ONE-LINE DIAGRAM CALCULATIONS <br /> in <br /> SCALE:NTS <br /> a <br /> 0 <br /> A City of Everett Permit Services <br /> EVERETT Reviewed for Permit 04/18/2025 E7,00 <br /> `o" <br />