LOAD CALCULATION FOR EXIST MAIN SWITCHBOARD MSBI DSJFWB <br /> ANNUAL PEAK DEAMND FROM UTIL 10 KW <br /> AT 9 PF I640 KVA LEGEND <br /> 25 <br /> NEC 25% 40 KVA <br /> CONDUIT CONCEALED IN CEILING OR WALLS up ENGINEERS <br /> ADDED LOAD 23.18 KVA i <br /> - - CONDUIT CONCEALED UNDERGROUND,UNDER FLOOR,OR IN WALL 4- 0 I 21 <br /> TOTAL LOAD 223.2 KVA 3/4"CONDUIT.TICK MARKS INDICATE NUMBER OF#12 WIRES.NO TICK MARKS y Travis Fitzmaurice Wartelle <br /> 268.6 AMPS (480V-3PH) EQUALS 2#12.GROUND WIRE NOT SHOWN.PROVIDE GROUND WIRE IN ALL 120V P43-21 Balangue Engineers Inc. <br /> EXIST MAIN SWITCHBOARD CAPACITY 800 AMPS AND ABOVE CIRCUITS. 1 zoo Westlake Ave.11,N119 <br /> 35 Seattle,WA 98109 <br /> EXISTING CONDUIT � - <br /> 1 p:• PROVIDE NEW CIRCUIT BREAKER �� HOME RUN TO DESTINATION INDICATED.1"MINIMUM UNLESS NOTED OTHERWISE. I I EXIST EF-406 206-285-7228 l info@tf-wb.com <br /> EX PANEL P43 I SECTION VOLTS 208 /I20 3 PHASE, 4 WIRE, WYE 11 <br /> LOCATION AMPS 100 DUPLEX RECEPTACLE <br /> MOUNTNG SURFACE MAIN LUGS ONLY <br /> AIC IOti 000 GROUND BUS DUPLEX RECEPTACLE ABOVE COUNTER },FIT, <br /> FED FROM P4 EXIST EF-409 ~oF WA, <br /> r�Zy <br /> ® 10 SPECIAL RECEPTACLE AS NOTED �I� '•i`mow <br /> CCT CCT DESCRIPTION LOAD I CCT CCT DESCRIPTION LOAD I I y. cF14- <br /> N0. BRKR KVA N0. BRKR KVA ® RANGE OUTLET,NEMA 14-50R O P43-28,30 7 33 _ <br /> 1 20/1 EX MCIROWAVE 1.00 2 20/1 EX DISPOSAL 0.30 f NEW RANGE I T <br /> I <br /> 3 20/1 EX DISPOSAL 0.30 4 20/1 EX RECEIPTS 0.54 ® EQUIPMENT CONNECTION - - RECEPTACLE AFssl s No1� <br /> 5 20/1 EX DSHWASHER 0.30 6 20/1 EX MICROWAVE 1.00 j c �� TYPICAL OF omA1,t;• <br /> 7 20/1 EX RECEIPTS 0.36 8 20/1 EX M I CROWAVE 1.00 t EXIST DEVICE/FIXTURE AS INDICATED <br /> 9 20/1 EX MICROWAVE I.00 10 20/1 EX DISPOSAL 0.30 II P 3-20 <br /> II 20/1 EX SPARE 0.00 12 20/1 EX DSPOSAL 0.30 334 1 y 1 <br /> 13 50/2 EX SPARE 0.00 14 20/1 SPARE 0.00 fQ" EXIST DEVICEJFIXTURE AS INDICATED TO BE REMOVED P43-8,10,12 <br /> IS I6 50/2• RANGE 8.00 11 FOOD cFi 1 <br /> 17 50/2 EX SPARE 0.00 18 i 208V OR 240V PANEL <br /> 19 20 50/2• RANGE 8.00 I <br /> 21 20/I EX SPARE 0.00 22 1 1=5 LVR C/2 R• j b 5 A �-_ <br /> FACSE <br /> 23 30 EX REFRIGERATORS 2.00 24 50/2• RANGE 8.00 EXIST F-0 <br /> 77 <br /> 25 0.00 26 09 480V PANEL <br /> 27 20/I SPARE 0.00 28 50/2• RANGE 8.00 ETTRANSFORMER <br /> 29 20/1 SPARE 0.00 30 <br /> 31 20/1 SPARE 0.00 32 20/1 SPACE o3 <br /> 33 20/1 SPARE 0.00 34 20/1 SPACE j <br /> 35 20/1 SPARE 0.00 36 20/1 SPACE ^- CIRCUIT BREAKER y� 1 <br /> 37 20/1 SPARE 0.00 38 20/3 EX TVSS 0.00 j �0 P43-24,26 3 <br /> 39 20/1 SPARE 0.00 40 I -� SWITCH i31 <br /> 41 SPACE 42 <br /> 31 6 EXIS1 EF408 <br /> FUSED SWITCH I 7 I <br /> I <br /> CONNECTED LOAD DEMAND FACTOR DEMAND LOAD 1 <br /> KVA KVA AMPS O Ca1 <br /> FUSE I( cn O Fi 1 / <br /> LIGHTS 0.00 125% 0.00 0.00 4 <br /> RECEPTACLES 4.90 100% 4.90 13.60 - <br /> HEATING 0.00 100% 0.00 0.00 <br /> LARGEST MOTOR 0.00 125% 0.00 0.00 TRANSFORMER m I I UY <br /> OTHER MOTORS 0.00 100% 0.00 0.00 1 � � <br /> RANGE 32.50 65% I2.28 44.41 - P432.4.6 P43`1 ®a3r1.35.. 1 <br /> KITCH. APPLIANCES 3.50 50% 6.00 4.31 GROUNDING PER CODES `t <br /> EXIST PANEL P43 <br /> 40.40 23.18 64.33 N BUS TAP 3 'I 1 <br /> GFI GROUND FAULT CIRCUIT INTERRUPTER -�'r 31 I ( 35 <br /> 2 2 2 2 2 <br /> 2R00R <br /> FOOD LAB FLOOR PLAN - NEW ELECTRICAL <br /> 1 SCALE:1/4"=V-0" EXIST OVEN TO BE DEMOLISHED. E V`,E RETT <br /> PUBLIC <br /> SCHOOL- <br /> CASCADE HIGH <br /> 4 O I14 y4 1y 21 LS ICJ SCHOOL FOOD <br /> EXIST PANEL DP4 <br /> 480YI277V-30-4W P43-13,15 P43-17,19 P43-21 <br /> LAB <br /> 1200 AMP <br /> AIC BELOW 10,000 A 35t 801 E Casino Rd <br /> BEYOND TRANSFORMER TP42 Everett,WA 98203 <br /> 19481 EXIST EF-406 <br /> I <br /> EXIST PANEL P43 I <br /> 208Y/120V-30-4W Date: 03/25/2025 <br /> M 100 AMP EXIST EF-409 Project No. 24-019 <br /> y GFi* <br /> P43-28,30 7 33 Drawn: AS <br /> EXIST 100A CIRCUIT BREAKER I EXIST.STOVETOP <br /> EXIST WITHIN 1 _ I TO BE DEMOLISHED Checked by: EL,MF <br /> PSE TRANSFORMER 26200 DRY TYPE TRANSFORMER TP42 15'OF TRANSFORMER 8G TYPICAL OF 4 <br /> (SERVICE POINT) 7318 45KVA CURRENT LIMITING <br /> 48OV:208Y/12OV-30-4W MAX 1000A AIC 4 P43- <br /> EX(4)3.5"-4#350,1#4 GND /1 33' 1 y�P43-8,10,12 I <br /> 800/3 M M EX 1"-3#4,1#8 GND EX 2"-4#2/0,2#4 GND EX 2"-4#2/0,2#4 GND 1 GFi 1 <br /> 70/3 /O 100/3 FOOD 91 <br /> EXIST - <br /> OR. 4 5A 5 CONSTRUCTION <br /> I <br /> SET <br /> WATER PIPE -•• <br /> STEEL-•� i I I `�y� I <br /> P43-24'26 7 31 FOOD LAB <br /> #4/0 CU N 3,I G EXIST EF-408 Gr'7 FLOOR PLANS <br /> - 1 -FER - ELECTRICAL <br /> I O <br /> I <br /> 4 T e1 <br /> I - <br /> SEE PANEL SCHEDULE <br /> �y �y U `I�.I TY <br /> #4/D a <br /> P43-2,4,6 P43-1 5,, <br /> I � <br /> 5� EXIST PANEL P43 <br /> �--4 31 I ( 35 <br /> 5 � _ ______________ A <br /> its r <br /> I I I I <br /> )R R I D O R Sheet No. <br /> n ONE LINE DIAGRAM FOOD LAB DEMO FLOOR PLAN - ELECTRICAL <br /> SCALE:NTS 2 E 1 . <br /> SCALE:1/4"=1'-0" <br /> ,.. ` City of Everett Permit Services <br /> EVERETT Reviewed for Permit 04/17/2025 <br />