My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD 2024 BLDG 07-587 Plans 2025-09-26
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 07-587
>
Plans
>
3003 W CASINO RD 2024 BLDG 07-587 Plans 2025-09-26
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/26/2025 10:43:01 AM
Creation date
9/9/2025 2:54:14 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 07-587
Permit
FA2406-005
Year
2024
Notes
7-587 BLDG FIRE ALARM
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FACP BATTERY CALCULATIONS SYMBOL LEGEND <br /> COMPONENTS QTY, STANDBY ALARM FACP FIRE ALARM CONTROL PANEL <br /> CURRENT CURRENT <br /> AFC-100(FACP) 1 0.13000A 0.22000A FAC I FIRE ALARM COMMUNICATOR (CELLULAR DIALER) <br /> UD-2000(DACT) 1 0.01600A 0.02300A <br /> SLC DEVICES SUPERVISORY ALARM FATC FIRE ALARM TERMINAL CABINET <br /> CURRENT CURRENT <br /> PAD300-PD 12 0.00030A 0.00030A 0.00360A 0.00360A FRPS FIRE ALARM REMOTE POWER SUPPLY <br /> PAD300-HD 2 0.00030A 0.00030A 0.00060A 0.00060A PHOTOELECTRIC SMOKE <br /> PAD-DUCT O 0.00030A 0.00030A o.000OOA O.000OOA Ox:zx DETECTOR, BRIGHT WHITE <br /> PAD100-PSSA/PSDA 6 0.00020A 0.00020A 0.00120A 0.00120A SUBSCRIPT XAX = DEVICE ADDRESS <br /> a Nw ppGj p� PAD100-MIM 6 0.00020A 0.00020A 0.00120A 0.00120A O <br /> H ADDRESSABLE HEAT DETECTOR <br /> 5 N PAD100-DIM O 0.00024A 0.00024A O.000OOA O.000OOA x:xx SUBSCRIPT X:XX = DEVICE ADDRESS <br /> MMM 2.13 OpG�p0 cuR"a�nlT cuRREnMiT ©x:xx MANUAL SUBSCRIPTLX:XXA- DEVICE ADDRESS <br /> �- a w' NAC CKT 1(AUX PWR) 0.018A 0.11000A 0.01800A 0.1170A MMM MINI MONITOR MODULE <br /> W. MMM 2 GA O30. NAC CKT 2(TRIG.) 0.o0A 0.01500A 0.000OOA 0.01500A xzz SUBSCRIPT X:XX = DEVICE ADDRESS <br /> SN' <br /> 5g5 Nw'OpG 5a"I pp SLC ALARM LED O,OOA 0.03600A I O.000OOA I 0.03600A (PROVIDED BY OTHERS) <br /> MMM 2 w j O�. MMM 2 SMpKE pE(ECAp? TOTA TOTAL STANDBY CURRENT DRAW= 0.1706 AMPS IST <br /> 0.4106A <br /> 24 ppG 11 CD <br /> MOUNTNDELAGRANGROBE <br /> MMM�25as OEj' S N/yaN Gjp? @ ppp?NZ STANDBY AMP HOUR STANDBY <br /> TOTALTIME <br /> 8.19H AH WP CEILINGWEATHER PROOF <br /> MOUNT HORN/STROBE <br /> 23 OpGj L1:10 pE�E Fp TOTAL ALARM CURRENT DRAW= 0.4106 AMPS CD = CANDELA RATING <br /> 5a5 Sw. R a� SMp� 5a� 00 X ALARM TIME 0.167 HOURS ® WALL MOUNT LSTROBING <br /> MMM'2 <br /> 2g5 S�`p?E pEZEGjp r2 S L1 08 p?F L1:09 STANDBY AHALARM P+OUR ALARM TOTAL <br /> AH = S.0 <br /> Z69AHH <br /> S�,5 SMp? SEZE jp? FN Fps @ pppR a� SMp�E pEZEpj %DE-RATING FACTOR 9.91 AH GENERAL NOTES <br /> G TOTAL AN REQUIRED 9.91 AH <br /> L1:21 M _CO MINIMUM BATTERY SIZE NEEDED: 10 AN <br /> S Say F L1a 0 S L1:07 pCE pE�EG�pR ?g.pppR NOTE: 0.167 EQUALS 10ATTERY ZMINURTESOF ALARM TIME BUILDING 7-587 FACP <br /> ARE ALL MONITORED BY <br /> L1:19 G�pR 5aH SM MENS <br /> pKE pE�E S�,5a� EjEG�pR Fp��'@ <br /> S 5a5 SM CEGApR L1:06 SMpµE p N F L1 616 MPN @ MENS?? aRculT uALCP ALVROLTAGE DROP CALCULATION <br /> CE VOLTAG REFERENCE DRAWINGS <br /> LRE TYPE <br /> _5165 SMpKE pE S L1:05 'ESEGjp? Pp� @pppR NEPj pE(EGjpR pM ?R NACi(AUX) 20.4 NAME VOLTAGE <br /> 0.1R10E AT #14AWG SOLID 3.19 1000 F 10 FEET0.064 RESISTANCE VOLTAGE 20.39 VDC 0.05%% <br /> 20.4 VDC 0.015 A #14AWG SOLID 3.19 is <br /> 20.38 MEG <br /> S L1:17 SMpCE pEZEGjpF 1 S EPGP SM0RE F L1a04MPN H L1 2aa Gjp?@ W ENS NAA2(rRlc 20.4 voc a.000 A #14AWG soup 3.1s o 0.0957 00.0o voc o%z% <br /> S 2'Sg5 �EGjpR @ Opp?N L1:03 gp a 0A pE�E R? pOp? N/A 20.4 VDC 0.000 A #14AWG SOLID 3.19 0 0 00.00 VDC 0% <br /> L1:16 p?E pE MPN?\S RPS AR H 2,5a wpMENS <br /> I_5g5 SM 1'Sg5 MMM 1:02 L1:26 <br /> S L1:14 pPGj�Re 1_Sa8 MP CONSTRUCTION NOTES <br /> A F L1:25 <br /> 1:01 RPS BATTERY CALCULATIONS PROVIDE AND INSTALL NEW DIGITAL ADDRESSABLE BUILDING <br /> FACP. PROVIDE PHENOLIC LABEL ON PANEL THAT READS: <br /> ALARM <br /> 7-587 SLC COMPONENTS <br /> CURRENT '7-587 FIRE ALARM CONTROL PANEL <br /> D D NAC CKT 1 (N3) 0.386A EVF-FA-7-587 <br /> 1-1 NAC CKT 2 (N4) 0.386A 120VAC FED FROM PANEL (T.B.D.)" <br /> 7-585 SLC 7-587 FATC 7-588 SLC NAC CKT 3 (N5) 0.248A <br /> PROVIDE CELLULAR COMMUNICATOR AND WIRE TO BUILDING <br /> NAC CKT 4 (NIS) 0.000A FACP. SEE SHEET E506 FOR INSTALLATION DETAILS. <br /> 7-588 NOTIFICATION 7-585 NOTIFICATION 7-587 NOTIFICATION RPS ALARM CURRENT 0.075A <br /> E.O.L. E.O.L. E.O.L. MONITORED BY TYCO AND INSTALL <br /> WP 110CD WP 110CD WP 110CD SIGNAL SENT TO CENTRAL TOTAL 1.095A NOTIFICATION D A NEW REMOTE POWER SUPPLY FOR <br /> DEVICES. <br /> BOEING FIRE DEPARTMENT <br /> TOTAL STANDBY CURRENT = 0.075A TOTAL ALARM CURRENT = 1.095A <br /> X ®PROVIDE AND INSTALL FIRE ALARM TERMINAL CABINET FOR <br /> STANDBY TIME 48 HRS X ALARM TIME 10 MINS (0.167) <br /> INTER-CONNECTION TO BUILDINGS 7-585 & 7-588 <br /> 15CD TCD 'ti"D STANDBY AMP HOUR 3.60AH ALARM AMP HOUR 0.183AH <br /> STANDBY AH + ALARM AH =3.783AH PROVIDE AND INSTALL NEW HORN/STROBES AS SHOWN ON <br /> PLANS. <br /> 15CD 75CD CELLULAR TOTAL AH X 20% DE-RATING 4.54AH <br /> ANALOG am`� PROVIDE AND INSTALL MANUAL PULL STATIONS AT EACH <br /> IN PRIMARY� TG-7FS-A REQUIRED BATTERY SIZE = 7AH EXIT. <br /> N N N <br /> I L 7-587 RPS 7-587 FACP 2 PROVIDE AND INSTALL DETECTION DEVICES AS SHOWN ON <br /> NAC3 NAC2 <br /> - PLANS. <br /> NAC4 RPS VOLTAGE DROP CALCULATION <br /> CIRCUIT SUPPLY ALARM OHMS NGT TOTAL LAST DEVICE �QP PROVIDE AND INSTALL MONITOR MODULES AS SHOWN ON <br /> NAGS ANA OG PHONE LINE NAME VOLTAGE CURRENT WIRE TYPE 000 FEET RESISTANCE VOLTAGE PLANS. <br /> SECONDARY) NACt (N3) 20.4 VDC 0.386 A #14AWG SOLID 3.07 95 0.5833 20.18 VDC 1.10% <br /> EVF-FA-7-587 EVF-FA-7-587 *TWO SEPARATE PATHWAYS FOR SIGNAL REQUIRED BY CODE,AS SHOWN. NAC2 (N4) 20.4 VDC 0.386 A #14AWG SOLID 3.07 195 1.1973 19.94 VDC 2.27% <br /> NAC3 (N5) 20.4 VDC 0.248 A #14AWG SOLID 3.07 85 0.5219 20.27 VDC 0.64% <br /> 3 120VAC 1 120VAC NAC4 (N6) 20.4 VDC 0.000 A #14AWG SOLID 3.07 0 0.000 20.40 VDC 0.00% <br /> BUILDING FIRE ALARM SYSTEM RISER <br /> SCALE: NONE E506-1 <br /> WIRE TAG DESCRIPTION <br /> CIRCUIT ID CIRCUIT DESCRIPTION WIRE DESCRIPTION <br /> B FACP SBUS CIRCUIT 4 CONDUCTOR, 16 AWG- FPLP <br /> C FACP VBUS CIRCUIT 4 CONDUCTOR, 16 AWG- FPLP <br /> D FACP SLC CIRCUIT 2 CONDUCTOR, 16 AWG- FPLP <br /> N NAC CIRCUIT 2 CONDUCTOR, 14 AWG- FPLP <br /> 1� P AUX CIRCUIT 2 CONDUCTOR, 14 AWG- FPLP <br /> V VOICE CIRCUIT 2 CONDUCTOR,16 ADS SOL-FPLP <br /> Z EQUIPMENT INTERFACE CKT. CONTRACTORS EQUIPMENT WIRING <br /> D. SH DATE SUBTITLE FIRE ALARM SYSTEM DETAILS CURRENT REVISION SYMBOL A DATE 05/09/24 <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ACCEPTABILITY J. SHELDON AT 09 24 n <br /> A FIRE ALARM PANEL INSTALLATION 34558629 AGOW JS AGOW KM 05 09 24 THIS DESIGN AND/OR CHECKED <br /> / / / m SPECIFICATION IS APPROVED K. MULLEN OS 10 24 SHEET <br /> -ABO'Er' w" E E506-1 <br /> APPROVED BY DEPT. DATE K. MULLEN OS 10 24 <br /> CHECKED <br /> APPROVED BUILDINGS 7-585, 7-587, & 7-588 JOB Na 34558629 COMP wo <br /> _�✓• APPROVED owc No. <br /> MDK EVERETT, WA FA-W2-7-587 <br />
The URL can be used to link to this page
Your browser does not support the video tag.