My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD 2024 BLDG 40-27 Plans 2025-09-09
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-27
>
Plans
>
3003 W CASINO RD 2024 BLDG 40-27 Plans 2025-09-09
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/9/2025 3:40:05 PM
Creation date
9/9/2025 3:40:00 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-27
Permit
FA2408-006
Year
2024
Notes
Fire Alarm T.I. Building 40-27
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A <br /> n 9A 913 9C I I9D 9.4 9E 9F 9G 9.8 _ <br /> 1 . D LEGEND: <br /> - - - - - - -L- - - -L- - - - - - - _ - _ - - - - - cu) <br /> M4 4 INPUT/4 OUTPUT MODULE <br /> STAIRS V ILL_ _ _ _ _ __ _ _ _ `-------_-'L--------"----- _ <br /> 105.5U9 H BELOW ~- EOLR OH CONVENTIONAL HEAT DEFECTOR <br /> 1 S D II I TO HVAC CONTROLLER U.1 B B 24K O ADDRESSABLE SMOKE DETECTOR <br /> ELEVATOR FOR HVAC S UT DOWN <br /> A I (D , 6"24VDC FIRE ALARM BELL <br /> 7.5U9 10 <br /> FROM 1:56 R 1:61 MECH/ELEC 1/1 1/2 ® ADDRESSABLE RELAY MODULE <br /> EO B 1 AB 5 ROOM NAC CIRCUIT TYPICAL WIRING TS SPRINKLER TAMPER SWITCH <br /> ___ _ _ _ JANITyR _ _—_� 110.5U9 U3 <br /> ----WOMEN-- --L --- ---� —+— --�-- 111.5U -- H� °- --- - - <br /> ,08.5D9 CONSTRUCTION NOTES <br /> BREAK ARE U'4 PROVIDE ADDRESSABLE SMOKE DETECTOR <br /> PLUMBING <br /> 102.5U9 <br /> CHASE - DP SPRINKLER VALVE TAMPER SWITCH PROVIDE AN ADDRESSABLE 4 INPUT/4 OUTPUT RELAY <br /> FDC10422 <br /> _ - - TO CONTROL ELEVATOR FUNCTIONS AND SPRINKLER <br /> U 6 EOLR DO NOT USE +1 B A TAMPER SWITCH MONITORING. <br /> DO NOT USE +16 A PRIMARY RECALL <br /> SLC IN - 6 B ALTERNATE RECALL PROVIDE CONVENTIONAL DUAL CIRCUIT 135- HEAT <br /> + U,7 SLC OUT - 6 + B DETECTOR WITHIN 18" OF PIT, SHAFT, AND MECHANICAL <br /> SLC IN + 5 - ROOM SPRINKLER HEAD. <br /> MEN - (E)STAIRS SLC OUT + 5 INPUT C <br /> 104.5U9 w LL 101. U,$ C HAT LIGHT ® PROVIDE 6" BELL FOR NOTIFICATION OF ELEVATOR FIRE <br /> ur D ALARM. <br /> ________---______ _ LL D SPARE <br /> --- -+_ 2 INPUT PROVIDE AN ADDRESSABLE RELAY TO SHUT DOWN THE <br /> _—_—_ _—_ _ —_ _—_—_ _ _—_—_— T 2 CH #2 HVAC UNIT UPON BUILDING PANEL ALARM. <br /> PLUMBINGCHASE <br /> 4 <br /> 03SU9 PARTIAL FLOOR PLAN LEVEL 1.5 EDLR 4 WIRE LEGEND <br /> SCALE: 1/8-T-O" N A = XDLC CIRCUIT - 2#16 FPLR OR FPLP WHERE REQUIRED <br /> B = NOTIFICATION APPLIANCE - 2#14 FPLR OR FPLP WHERE <br /> A ( --�Kt- ------ -------� REQUIRED. <br /> MACH. RM. <br /> — G FAD NETWORK CKT. - TWISTED SHIELDED CABLE (4#16 <br /> D = IFD INPUT CIRCUIT - #18 TSP, TYPE FPL OR CM <br /> 1 E = 24VDC AUX PWR. CKT - 2#16 THHN (STRANDED) <br /> 9 9A 96 12BJI <br /> 9D 9.4 9E 9F 9G 9.8 li I II 2#12 <br /> I I II <br /> ELEVATOR PAR. <br /> :58 SHUNT TRIP57:11 SPRINKLER VALVE SWITCH - - - - - - - - - - - - - - - - - - - HU - �� - cPINT NLMBER NOMENCLATURE <br /> 1:57:12 HEAT DETECTOR PIT AND TOP OF SHAFT - II 1:57:13 HEAT DETECTOR MACHINE ROOM - - - - - - - - - - - - - - - - - PIT (BY OTHERS) EOL 1: 01 11 <br /> 1:57:14 SHUNT TRIP MONITOR III POWER <br /> E I ELEVATOR SUWE 0 <br /> 1:57:21 PRIMARY FLOOR RECALL 107U9 1,1 RELAY 0 MONITORING INPUT NUMBER: <br /> li <br /> 1:57:22 ALTERNATE FLOOR RECALL I;, III A,26 <br /> 1:57:23 ELEVATOR HAT LIGHT =- -L-,_- SHUNT 0 --J 11 - INPUT 1 <br /> 1:57:24 SPARE TAfR H 3 oLR ACTIVATION ----� 13 - INPUT 3 <br /> 2 <br /> M4 <br /> CNTRL. <br /> 105U91 <br /> I <br /> I A 14 - INPUT 4 <br /> 280 S D 3 1.5 I --$iI$-- J 21 - RELAY 1 <br /> EXIT HALLW M—' EO TS UP TO 1:59 ELEV.MECH. 22 - RELAY 2 <br /> -- --- — -- 1 - k6------ - ROOM --- ------ --- -—-—- <br /> U 3 TOP OF SHAFT <br /> 104U9Q-- --I--- 23 - RELAY 3 <br /> 24 - RELAY 4 <br /> 331 SF <br /> 62SIF U4 ELEVATOR MACHINE ROOM ADDRESSABLE DEVICE NUMBER <br /> E)OPEN SPACE HEAT DETECTOR, SHUNT TRIP MONITORING <br /> (E)STAIR G UPI AND FIRE HAT SIGNAL WIRING (TYP.) SIGNALING NE CIRCUIT NUMBER <br /> AB 102U9 101U9 <br /> 2405 SF <br /> -------I ---------L-- -- - -- -- ----- u.7 <br /> IF SHIELEDED GORE IS USED, SIEMENS <br /> CONNECT DRAMS TOGETHER& <br /> INGUTATE FRO.GROUND. HTRI-R <br /> SLC IN <br /> TO CP ----- u'$ S CKT.ITS CKT.OUT A <br /> COL.'V/8.6 ----- <br /> j l A e Z'CDAS O�Tnms LED <br /> �,Q .p�1' �vl ��yl Eql fp1'�, <br /> --_ INPUT I ltr----T----T----T----T----�^l <br /> I <br /> e <br /> e 4 CONTACTTS TTr 7 10 11 12 13 14 <br /> 5 CND e ONPUT TO DEVICE BOND <br /> o o _ aals0VDC CONTRDum@oaR OO-F----+----+----+----+----�-0 <br /> c l ____ ___ 18 19 <br /> 4g30VDC 6 RELEASE RN SHUTWWN, 15 18 17 <br /> ETC)SELECT NC OR NO <br /> I I I I I I I CONTACTS AS REWIRED. [}F- +_ +____+____+____� <br /> �OOSTER DUMP SELECT MRE GJACE AS <br /> 0 o REOUIRED. 20 21 22 23 24 <br /> I I I <br /> 25 26 27 28 29 <br /> 345 SF o 0 0 0 0 0 ]w <br /> PARTIAL FLOOR PLAN LEVEL 1 TYPICAL WIRING D 1 RELAY ADDRESSABLE MONITOR MODULE DIAGRAM <br /> ° 30 31 32 33 <br /> HTRI-R 1 INPUT <br /> SCALE: 1/8"lCO' ———KEY PLAN <br /> Timothy C.Eastman-253 Q Q2� <br /> NICETCertifcation�� 2L PO BOX 1138 <br /> ! r Systems-Cevel IV AOBURN,wA 98071 <br /> /n SEATRONICS 253-939-6060 <br /> fi ICatIOn Exp,ires.March 01,2025 FIRE PROTECTION SERVICES dDB NO. OWC No. <br /> ARA100 10403203 9132326—E2 <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE <br /> ACCEPTABILITY DRAWN DATE <br /> 24 SUBTITLE PARTIAL FLOOR PLAN LEVEL 1.5 CURRENT REVISION SYMBOL - DATE 4.11.24 <br /> A FIRE ALARM SUBMITTAL SEA SEA 4.11.24 THIS DESIGN AND/OR CHECKED <br /> SPECIFICATION IS APPROVED SHEET <br /> ®E/ APPROVED BY DEPT. DATE ENGINEER TITLE BREAKROOM AND RESTROOM ADD E2 2 <br /> BOA/G <br /> CHECKED <br /> APPROVED BUILDING 40-027 JOB NO. COMP NO. <br /> 9132326 , <br /> APPROVED ELECTRICAL MASTER COL 9- 9.8/ U-V 10403203 DWG No. 40-027-E2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.