Laserfiche WebLink
1 2 3 4 5 <br /> V £ <br /> 4J Xago <br /> Stantec Swbd <br /> Name AIEMLDP2 120/208V 3PH 4W 2000A Main CB Type:Switchboard o o <br /> Location:MECH/ELEC#2 Surface Mounted OAIC U a <br /> Serves: Single Lugs ab� <br /> Dem. Dem. <br /> Load Type Conn KVA NEC Demand Factor KVA Amps NEC Feed% NEC Feed Amps N go2g` <br /> Equip 3.33 x 10D% 3.33 9 x 100% 9 ° C) <br /> Recorded Demand 240.00 x 125% 300.00 833 x 100% 833 N.F _ <br /> D Swbd AlELDPI Recorded Demand calculated as 240.O0kVA x 10D%S.A.F.x 100%O.A.F. -O c,e E e <br /> Recorded Demand 184.04 x 125% 230.05 639 x 300% 639 a,z a <br /> Swbd AICLDP2 Recorded Demand calculated as 184.04WA x 100%S.A.F.x 100%0.A.F. o 2 2 <br /> 427.37 1,186 Amps 533.38 1,481 1,481 U a€ <br /> Stantec Swbd <br /> Name EUS-EH3 277/480V 3PH 4W 4000A Main CB Type:Switchboard _ <br /> Location:EMERGENCY POWER RM Surface Mounted 65,000 AIC <br /> O <br /> Serves: Single Lugs <br /> Dem. Dem. <br /> 0 <br /> Load Type Conn KVA NEC Demand Factor KVA Amps NECFeed% NEC Feed Amps U <br /> Equip 51.16 x 100% 51.16 62 x 100% 62 <br /> Stantec Dist PnI Lighting 15.85 x 100% 15.85 19 x 125% 24 <br /> Name BBIELDPI 120/208V 3PH 4W 600A Main lugs only Type:Distribution Panel <br /> Motors 76.00 x 100% 76.00 91 125%of Largest 114 <br /> Location:BASEMENT BELOW RADIOLOGY Surface Mounted 0 AIC Pat.Room 5.76 50 KVA @ 409A,rest @ 20°,6 2.30 3 x 300% 3 <br /> Serves: Single Lugs Recept 27.36 10 KVA @ 100%,rest @ 50% 18.68 22 x 100% 22 <br /> Dem. Dem. Recorded Demand 39.39 x 125% 49.24 59 x 100% 59 a <br /> Load Type Conn KVA NEC Demand Factor KVA Amps NEC Feed% NEC Feed Amps Dist PnI A1XLDP1 Recorded Demand calculated as 39.39kVA x 100%S.A.F.x 100%O.A.F. <br /> Equip 24.69 x 100°A 24.69 69 x 100-A 69 Recorded Demand 240.00 x 125% 300.00 361 x 3001A 361 <br /> Lighting 22.40 x 100°A 22.40 62 x 125% 78 Swbd AIELDP3 Recorded Demand calculated as 240.00kVA x 100%S.A.F.x 100%O.A.F. <br /> Mech 0.70 x 100% 0.70 2 125%of Largest 2 Recorded Demand 184.04 x 125% 230.05 277 x 100% 277 <br /> Recept 53.36 10 KVA @ 100%,rest @ 50% 31.68 88 x loop 88 Swbd AICLDP2 Recorded Demand calculated as 184.04kVAx 300%S.A.F.x 100%O.A.F. <br /> 101.14 281 Amps 79.46 221 237 Recorded Demand 206.25 x 125% 257.81 310 x 100% 310 <br /> Swbd AICLDPI Recorded Demand calculated as 206.25kVAx I00%S.A.F.x l0o%O.A.F. <br /> Recorded Demand 25.56 x 125% 31.95 38 x 100% 38 <br /> C Dist PnI D1EHDP Recorded Demand calculated as 25.56kVA x 100%S.A.F.x 100%O.A.F. 0 <br /> 871.37 1,DU Amps 1,033.04 1,243 1,270 � <br /> 0 <br /> Stantec Swbd <br /> Name PMVS-CP 0/4160V 3PH 3W 2000A Main lugs only Type:Switchboard <br /> Location:UTILITY PLANT PARALLELING GEN RM Surface Mounted 40,000AIC z IQ <br /> Serves: Single Lugs <br /> Stantec Swbd <br /> Name A1ELDP1 120/208V 3PH 4W 12" Main lugs only Type:Switchboard Dem. Dem. <br /> Location:MECH/ELECT#2 Surface Mounted 65,000AIC Load Type Conn KVA NEC Demand Factor KVA Amps NEC Feed% NEC Feed Amps Im <br /> Serves: Single Lugs Equip 179.37 x 100% 179.37 25 x 100% 25 <br /> Dem. Dem. Lighting 57.13 x 100% 57.13 8 x 125% 1 i <br /> Load Type Conn KVA NEC Demand Factor KVA Amps NEC Feed% NEC Feed Amps Mech 9.64 x 100% 9.64 1 125%of Largest 2 <br /> Motors 458.33 x loop 458.33 64 125%of Largest 71 0 <br /> Equip 3.33 x loop 3.33 9 x loop 9 Pat.Room 5.76 50 KVA @ 40%,rest @ 20% 2.30 0 x 100% 0 o <br /> Recorded Demand 240.00 x 125% 300.00 833 x 100% 833 Recept 48.78 10 KVA @ 100%,rest @ 50% 29.39 4 x 100% <br /> *Recorded Demand calculated as 240.00kVA x 100%S.A.F.x 100%O.A.F. Recorded Demand 39.39 x 125% 49.24 7 x 100% 7 z <br /> 243.33 675 Amps 303.33 842 S42 0 <br /> Dist PnI AIXLDPS Recorded Demand calculated as 39.39kVAx100%S.A.F.x100%O.A.F. 0 a <br /> Recorded Demand 138.78 x 125% 173.48 24 x 100% 2 _ <br /> Dist Pnl GAOHl Recorded Demand calculated as 138.78kVA x 300%S.A.F.x 100%0.A.F. <br /> Recorded Demand 313.33 x 125% 391.66 54 x 100% 54 Permit/Seal <br /> Swbd FREHDP4 Recorded Demand calculated as 313.33kVA x 100%S.A.F.x 100%O.A.F. <br /> Recorded Demand 648.91 x 125% 811.14 113 x 100% 113 L A N <br /> Cf� <br /> Swbd FBEHDPI Recorded Demand calculated as 648.91kVA x 100%S.A.F.x 100%O.A.F. WAS�!��of y2�"ram <br /> Recorded Demand 383.91 x 125% 479.89 67 x 100% 67 <br /> Swbd FREHDP3 Recorded Demand calculated as 383.91kVA x 100PA S.A.F.x 100%O.A.F. <br /> B Recorded Demand 174.00 x 125% 217.50 30 x 100% 30 " <br /> Swbd FBCHDP2 Recorded Demand calculated as 174.00kVAx 100%S.A.F.x 300%O.A.F. 'd9oF sae sTeR `04 <br /> Stantec Swbd Recorded Demand 78.35 x 125% 97.94 14 x 100% 14 FSS7 E1yG� <br /> Name NUS-EH1 120/208V 3PH 4W 5000A Main CB Type:Switchboard Swbd F4CHDP4 Recorded Demand calculated as 78.35kVA x 100%S.A.F.x 100%O.A.F. AYAI. 04/01/2025 <br /> Location:NORMAL POWER ROOM Surface Mounted 100,000 AIC Recorded Demand 161.22 x 125% 201.52 28 x 100% 28 <br /> Serves: Single Lugs Swbd FBCHDP1 Recorded Demand calculated as 161.22kVAx 100%S.A.F.x 100%O.A.F. <br /> Dem. Dem. Recorded Demand 240.00 x 125% 300.00 42 x 100% 42 <br /> Load Type Conn KVA NEC Demand Factor KVA Amps NEC Feed% NEC Feed Amps Swbd AlELDPI Recorded Demand calculated as 240.00kVA x 100%S.A.F.x 100%O.A.F. <br /> Equip 72.47 x 100% 72.47 201 x 100% 201 Recorded Demand 206.25 x 125% 257.81 36 x 100% 36 <br /> Lighting 20.38 x100% 20.38 57 x125% 71 Swbd A1CLDP1 Recorded Demand calculated as 206.25kVA x 100%S.A.F.x 100%O.A.F. <br /> Mech 13.81 x 100% 13.81 38 125%of Largest 43 Recorded Demand 28.89 x 125% 36.11 5 x 100% 5 <br /> Pat.Room 12.60 50 KVA @ 40%,rest @ 20% 5.04 14 x 100% 14 Panel GALK Recorded Demand calculated as 28.89kVA x 100PA S.A.F.x 100%O.A.F. J N <br /> Recept 59.39 10 KVA @ 100%,rest @ 50% 34.69 96 x 100% 96 Recorded Demand 1,426.87 x 125% 1,783.59 248 x 1OD°.6 248 Q LU <br /> Recorded Demand 576.42 x 125% 720.53 2,000 x loop 2,000 Swbd PMOHDPS Recorded Demand calculated as 1,426.87kVAx 100%S.A.F.x 1009A O.A.F. <br /> U CL U <br /> *Recorded Demand calculated as 576.42kVA x 100%S.A.F.x 100%O.A.F. Recorded Demand 13.68 x 125% 17.10 2 x 100% 2 Lu Q <br /> 755.08 2,0%Amps 866.93 2,406 2,425 Panel P1XH1 Recorded Demand calculated as 13.68kVA x 100%S.A.F.x 100%O.A.F. U w <br /> z Recorded Demand 155.56 x 125% 194.45 27 x 30D°k 27 J m U Q <br /> z LLJ <br /> Swbd PIEHDPI Recorded Demand calculated as 155.56kVA x 100PA S.A.F.x 100%O.A.F. Z U <br /> Recorded Demand 148.45 x 125% 195.56 26 x 100% 26 U(� mQ <br /> w <br /> a Swbd FBNHDP2 Recorded Demand calculated as 148.45kVAx 100%S.A.F.x 100%O.A.F. w <br /> Recorded Demand 582.22 x 125% 727.78 101 x 100% 101 � LU p w <br /> Swbd FBEHDP2 Recorded Demand calculated as 582.22kVA x 100%S.A.F.x 100%O.A.F. ckftie <br /> Ld <br /> Recorded Demand 63.16 x 125% 78.95 11 x loop 11 4U> Z Lu Q co Swbd FRCHDP3 Recorded Demand calculated as 63.16kVA x 100%S.A.F.x 100%O.A.F. <br /> Recorded Demand 29.29 x 125% 36.61 5 x 100% 5 Q w U O <br /> 1 LU Z U <br /> Panel F4XHDP4 Recorded Demand calculated a529.29kVAx 100%S.A.F.x 100%O.A.F. Q Z <br /> NLIJ <br /> Recorded Demand 40.40 x 125% 50.50 7 x 100% 7 V a U CL <br /> Panel 1BXHDP1 Recorded Demand calculated as 40.4OkVA x 200%S.A.F.x 100%O.A.F. <br /> A Recorded Demand 26.26 x 125% 32.83 5 x 100% 5 Project NO.:204823068 <br /> Panel FRXHDP3 Recorded Demand calculated as 26.26kVA x 100%S.A.F.x 100%O.A.F. <br /> Recorded Demand 25.56 x 125% 31.95 4 x 100% 4 Scale:NONE <br /> U MEH MEH NCA 2025.04.01 <br /> Dist Pnl DIEHDP Recorded Demand calculated a5 25.56kVA x 10096 S.A.F.x 100%O.A.F. _ <br /> Recorded Demand 184.04 x 125% 230.05 32 x 100% 32 D- Dsgn. Chkd. YYYY.MMOD <br /> Swbd AICLDP2 Recorded Demand calculated as 184.04kVA x 300%S.A.F.x 100%O.A.F. Title <br /> X-Ray 100.00 Largest @50%,next @ 25%,rest @ 10% 50.00 7 x100% 7 LOAD SUMMARIES <br /> 5,967.54 928 Amps 7,171.82 995 1,005 <br /> LOAD SUMMARIES <br /> 0 <br /> EVE`TT Reviewed for Permit 04 09 2025 Drawing NO. <br /> g E9.1 <br /> !N ORIGINALSHEF ARCH <br />