1711 ENGLAND AVE 2024 Plans 2025-09-10
>
Address Records
>
ENGLAND AVE
>
1711
>
Plans
>
1711 ENGLAND AVE 2024 Plans 2025-09-10
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/10/2025 11:25:32 AM
Creation date
9/10/2025 11:25:21 AM
Metadata
Fields
Template:
Address Document
Street Name
ENGLAND AVE
Street Number
1711
Permit
B2401-005
Year
2024
Notes
INSTALLATION OF 13 HECLICAL PILES TO STABLIZE FOUNDATION
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
4
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�.�. PROPERTY LINE <br /> 74,_D„ <br /> i PILE SPACING&LOAD REQUIREMENTS TABLE •T <br /> i MAX O.C.SPACING,R MIN VERTICAL CAPACITY,kips PROOF TESTING LOAD,kips #T <br /> 200%MIN VERTICAL <br /> A <br /> PILE q PILE TYPE LOCATION <br /> BTWN PILES END OFFSET ALLOWABLE LOADING CAPACITY <br /> F\ I _ (MIN ULTIMATE CAPACITY) <br /> 1-2 PER PLAN 10.0 k/PILE 20.0 k/PILE GARAGF <br /> 3-5 HELICAL PER PLAN 6'-0" 6.0 k/PII� 12.0 k/PILE <br /> 68 PER PLAN 9.0 k/PILE 1R.0 k/PILE PLiRCH <br /> 9 13 6'-0" 10.0 k/PILE 20.0 k/PIII-C <br /> 00549401001800 EXTERIC}R <br /> PARCEL NOTES: <br /> 01 I <br /> ! LEGAL DESCRIPTION a. MINIMUM AND MAXIMUM INSTALLATION TORQUE FOR HELICAL ASSEMBLIES SHALL BE SPECIFIED BY THE PILE <br /> QUEEN DESCRIPTION <br /> ADD TO EVERETT BLK I MANUFACTURER.THE MINIMUM INSTALLATION TORQUE SHALL BE HIGH ENOUGH TO ACHIEVE THE REQUIRED BEARING <br /> QUEEN <br /> EN -E ANNE AD OF LOT 18 ALL LOTS I CAPACIT,LOADING,INCLUDING A SAFETY FACTOR NO LESS THAN 2.THE MAXIMUM INSTALLATION TORQUE SHALL NOT <br /> 01& -0 W5FT OF LOT 21 EXCEED THE ALLOWABLE TORSIONAL CAPACITY OF THE PILE SHAFTS OR ANY PART OF THE PILE ASSEMBLY.MAXIMUM 1 <br /> INSTALLATION TORQUE RATING OF B,30DFT•LBS FOR A 2-7/8 INCH DIAMETER HELICAL PILE WITH 0.203 INCH SHAFT WALL w <br /> OWNER NAME 8 ADDRESS THICKNESS PER ESR-3750. 0 z <br /> b. FOR HELICAL PILES,PER IDEAL GROUP DWG NO.:278TFG,THE ALLOWABLE STRUCTURAL CAPACITY FOR THE 2 718" <br /> STAYNER LARRY R&MARILYN L I TRU-FORCE UNDERPINNING BRACKET IS LIMITED TO 30 KIPS. 1 0 <br /> 1711 ENGLAND AVE c. HELICAL ASSEMBLIES AS MANUFACTURED BY IDEAL MANUFACTURING,INC., IN ACCORDANCE WITH ESR-3750. LL� Z <br /> EVERETT,WA 98203 d.PILE OR ANCHOR LOADS NOT TO EXCEED MAXIMUM CAPACITY AS DETERMINED BY THE MANUFACTURER FOR ANY PART r W <br /> OF THE ASSEMBLY. <br /> 0.MAXIMUM ON-CENTER SPACING LISTED FOR TYPICAL PILE INSTALLATION UNLESS NOTED OTHERWISE ON PLAN. A•,J w <br /> ZZz <br /> I FOUNDATION NOTES o <br /> w <br /> 1. VERIFY ALL DIMENSIONS ON SITE, <br /> i2. FOUNDATION DIMENSIONS ARE TO OUTSIDE FACE OF CONCRETE STEM WALL PER R&R LEVEL SURVEY.3. REFER TO THE FOLLOWING DETAILS FOR ADDITIONAL INFORMATION: <br /> ' I HELICAL PILE..........VSD-1.1 <br /> 4. REFER TO STRUCTURAL CALCULATIONS PACKAGE DATED DECEMBER 19TH,2023,FOR ADDITIONAL INFORMATION.SPECIFICATIONS,AND REQUIREMENTS. <br /> 5. LEVEL SURVEY PER R&R REPAIR PLAN DATED OCTOBER 18TH,2023.REFER TO STRUCTURAL CALCULAT70NS PACKAGE FOR MODIFICATIONS AND <br /> ADDITIONAL REQUIREMENTS FOR REPAIR PLAN. <br /> 53'-0" 8. MINIMUM PILE DIAMETER SHALL BE2-71B'. <br /> 7. IT IS ACCEPTABLE TO INSTALL PILES AT THE SPACING SHOWN WITH t 0'-W TOLERANCE TO ALLOW FOR UNEXPECTED OBSTRUCTIONS ENCOUNTERED <br /> v I I DURING PILE INSTALLATION PROVIDED THAT NO TWO ADJACENT SPANS EXCEED THE SPACING LIMITATION AS INDICATED ON LEVEL SURVEY. <br /> O• I B. FIELD VERIFY ALL EXISTING STEM WALLS AT AND BETWEEN PILE ATTACHMENT LOCATIONS ARE 8"THICK MINIMUM WITH YA"HEIGHT(MEASURED FROM <br /> m c B/FTG TO TICONC)MINIMUM. <br /> 9 r I I Z . PARCEL AND RESIDENCE LOCATING DIMENSIONS(WITH ASTERISK,')APPROXIMATED PER SNOHOMISH COUNTY iMAP.NOT TO BE USED FOR LEGAL <br /> m l e l PURPOSES. <br /> o <br /> 10.SITE FEATURES AND EXISTING STRUCTURES ON ADJACENT PARCELS NOT SHOWN FOR CLARITY. <br /> m RESIDENCE 1711 ENGLAND AVE 11.PILES SHALL BE INSTALLED TO A MINIMUM EMBEDMENT OF V-0"(LINO PER GEOTECHNICAL REPORT). <br /> p 0 <br /> EVERETT.WA 98203 tV a <br /> �y HELICAL PILE REFUSAL CRITERVC <br /> TORQUING OF THE PILE SHALL CONTINUE UNTIL A HYDRAULIC PRESSURE IS ACHIEVED TO PROVIDE THE SPECIFIED MINIMUM VERTICAL CAPACITY WITH <br /> A SAFETY FACTOR OF NO LESS THAN TWO.ADVANCEMENT SHALL BE HALTED IMMEDIATELY IF THE STRUCTURE BEGINS TO EXPERIENCE UPLIFT FLEXURE. <br /> k3'- 1711 ENGLAND AVE <br /> 13 EVERETT <br /> o J WA 98203 <br /> 5 i 3' S0' <br /> � 12 3/4 , 1,:, �,�� S231120-2XR <br /> 12'-0' JT <br /> �N q I m ,� MRT <br /> I 8vr 7 �� N � 3/4 -3/4 ,,., ,.:I 1,a N 12/19/2023 <br /> a< io N <br /> iT ! <br /> 3 i 1 <br /> -1 112 -1 1/2 1/2 <br /> i 13 LOCATE PILE 3' <br /> 2 1 SITE PLAN LEGEND WITHIN 3-0- N _H N 1 10' a u T P) <br /> OC MAX FROM CORNER w,/{ <br /> 31.1 5 10' <br /> 6 I EXISTING RESIDENCE STRUCTURE 3 10 1/4 9 1 <br /> � 12' <br /> 24'-0" <br /> I <br /> ! EXISTING ADJACENT STRUCTURE (')4 �l <br /> _-- PILES C6 6'-0'OC MAX� � 'A <br /> AREA OF PROPOSED WORK <br /> a N 3 ;. <br /> w w I PROPERTY LINE {r=Helical Plies m <br /> 2 0 I ar4 1 IB_ :{ <br /> F4 =EYisling Foal _ --- - -- <br /> a APPROXIMATE DIMENSION e 2 24 <br /> \ t <br /> CENTER PILES ON l\ LOL PILES UNDER <br /> HELICAL PILE EXISTING POSTS BUN D KING a JACK <br /> STUDS YING GARAGE <br /> OOR HEA <br /> DER <br /> DER <br /> _ _ _ _ I R&R LEVEL SURVEY Z <br /> I• •—�—"—' 79'D7•' •—•—•—•—•—•— See Structural Calculation Package for Additional Requirements Q r� <br /> a ' <br /> OPERTY LINE <br /> NOTE: THE PROJECT WILL NOT RESULT IN CHANGING OF SITE TOPOGRAPHY OR EXISTING DEVELOPED AREAS. SITE PLAN <br />