My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
906 SE EVERETT MALL WAY 2024 MEDIX INFUSION Plans 2025-09-10
>
Address Records
>
SE EVERETT MALL WAY
>
906
>
MEDIX INFUSION
>
Plans
>
906 SE EVERETT MALL WAY 2024 MEDIX INFUSION Plans 2025-09-10
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/10/2025 2:12:05 PM
Creation date
9/10/2025 2:11:33 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
906
Tenant Name
MEDIX INFUSION
Permit
B2411-057
Year
2024
Notes
Interior office TI on the fourth floor. SUITES 400 AND 402
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ww �� <br /> �� m= <br /> LIGHTING NOTES LEGEND m; <br /> _- <br /> w- <br /> LIGHTING SCHEDULE w x m <br /> ENERGY CODE: 2021 WA STATE ENERGY CODE A❑ NEW 2X2 LED TROFFER � <br /> COMPLIANCE PATH: PRESCRIPTIVE LIGHTING PER CH.15 ID DESCRIPTION QTY MFR PRODUCT LINE/SERIES ITEM NO. FINISHICOLOR BATTERY BACKUP WATTS NOTE <br /> INTERIOR LIGHTING: 0.64 WIfF LIGHTING ALLOWANCE(OFFICE) <br /> NEW lX4 LED TROFFER <br /> SUITE 400 A Tx 2'TROFFER 8 LITHONIA LIGHTING CPX LED PANEL TBD WHITE FINISH ❑ 28 3500K <br /> 0.64 X 2,440=1562 WATTS ALLOWED C� NEW LED VANITY BAR Y Co <br /> O <br /> (8X28 WATTS)+(26X25 WATTS)+(3X3 WATTS)+11 WATTS=894 WATTS B Vx4'TROFFER 36 LITHONIA LIGHTING CPX LED PANEL TBD WHITE FINISH El 25 3500K ® ®1' EXIT SIGN I DIRECTIONAL WI ('V <br /> EMERGENCY LIGHTING Q 00 co <br /> SUITE 402 <br /> 0.64 X 866=554 WATTS ALLOWED C VANITY BAR 1 TBD TBD TBD TBD El 11 3000K O EXHAUST FAN W <br /> W 9 X 25 WATTS+3 WATTS=228 WATTS PROVIDED EDGE LIT MATCH SURFACE <br /> �, <br /> EXITA EMERGENCY SIGN 4 LITHONIA LIGHTING LED EDGE LIT SERIES ELXTEU2 EXISITNG ® 3 MOUNTED ® OCCUPANCY SENSOR D F---` <br /> 49 LL v) w <br /> OWAP WIRELESS ACCESS POINT LL ce <br /> O = LJ..I <br /> SWITCH/3-WAY SWITCH LLJ <br /> POP RIVET DIMMER SWITCH I MOTION Q Q <br /> APPROVEDED > <br /> ATTACHMENT METHOD C :3m <br /> L J <br /> • • PRIMARY DAYLIGHT ZONE _ -J <br /> g 6" 8"MPX. <br /> 8 W <br /> m u' <br /> SECONDARY DAYLIGHT L.L .i W <br /> O ZONE L.0 <br /> u 2"PERIMETER WALL LLJ <br /> S C <br /> I MOLDING TYP. LJJ C W <br /> r STABILIZER BAR NO WORK IN SHADED AREA 0 Lu <br /> N <br /> r <br /> C U <br /> R 1.0 <br /> R <br /> is <br /> DEFERRED ELECTRICAL AND NOTES: <br /> MECHANICAL PERMIT REQUIRED <br /> ALL HVAC TO REMAIN(NOT 1. ELECTRICAL WORK SHALL CONFORM TO THE <br /> SHOWN)MNECESSRELOCATE <br /> E OCATEAS GRID(al ATTACHED WALL GRID (a' UNATTACHED WALL REQUIREMENTS OUTLINED IN2021WSEC. <br /> F-III <br /> 2. LIGHTSWITCH LOCATIONS SHOWN ARE ESTIMATED <br /> LOCATIONS AND SHALL BE VERIFIED WITH OWNER <br /> PRIOR TO ELECTRICAL WORK. (n <br /> GRID C WALL NOTES: 3. ALL LUMINAIRES SHOWN ARE NEW,EXCEPT THOSE <br /> NOTED OTHERWISE. <br /> 1.GRID TO BE ATTACHED TO WALL ANGLE ON TWO ADJACENT WALLS N <br /> 4. HVAC WORK,INCLUDING CONTROLS,TO BE cc <br /> 2.WALLS WITH UNATTACHED GRID TO HAVE 3/4'CLEARANCE BETWEEN RUNNER PERIMETER SUPPORT MODIFIED AS NECESSARY UNDER DEFERRED W <br /> ENDAND PARTITION WIRE @ EA.RUNNER SUBMITTAL BY DESIGN-BUILD CONTRACTOR. 10 <br /> 12 GAUGE HANGERS @ ON <br /> OPEN INFUSION ATTACH HANGERS TO 5. CEILING GRID TO REMAIN;TILES TO BE REPLACED AS <br /> AREA NOTED AND NECESSARY.REPLACED CEILING TILES <br /> 400 STRUCTURAL FRAMING TYPICAL THROUGHOUT WITH ARMSTRONG ULTIMA <br /> MEMBERS WITH 114"0 LAY 24"X 24"OR SIM.NRC=0.75,CAC=40. <br /> 1,406.2 s k REPAIR/REPLACE EXISTING GRID EYEBOLTS PENETRATING 1 <br /> 8 114"INTO STRUCTURE. 6. DEMOALL OBSOLUTE WIRING,DUCTWORK,ETC. <br /> FFI _ AND ACT AS NECESSARY <br /> c WALLANGLE 7. EMERGENCY LIGHTING SHALL COMPLY WITH IBC <br /> 5 AP \ SECTION 1008.PROVIDE EMERGENCY LIGHTING w m <br /> 8" ARRANGED TO ACHIEVE A MINIMUM ILLUMINATION <br /> g LEVEL OF 1 FOOT CANDLE AT THE WALKING <br /> N \ R T EI 112"0 EMT COMPRESSION SURFACE.EMERGENCY LIGHTING SHALL NOT BE ON k7 � <br /> k 2 ABV. <br /> SEES /dam STRUT TYR@DIAGONAL OCCUPANCY OR DAYLIGHT CONTROLS. g � cn <br /> y 1 BRACE:MAXVSHORTER <br /> 1 THAN WIRE 8. MODIFYSWITCHING AS SHOWN ON PLAN.NEW U H 0 <br /> SUITE 425 STRUTS CLOSER.@12A"O.C.OR THROUGHOUT <br /> SENSORS SHALL BEPROVIDED <br /> A.LEVITON WALL SWITCH OCCUPANCY SENSORS IN R Z <br /> WHITE SHALL BE PROVIDED IN ALL OFFICES,OPEN a <br /> R P71 1 1 INFUSION AREAAND RESTROOMS. r <br /> a A B.LEVITON CEILING MOUNTED OCCUPANCY IZ >¢ <br /> a .1 s 40 40 C SENSORS IN WHITE SHALL BE PROVIDED.INSTALL 1 Q > <br /> L5 9. s 13 HEAVY DUTY COMMERCIAL MULTIPLE SENSORS AS REQUIRED TO PROVIDED <br /> _ ® MAIN AND INTERMEDIATE COVERAGE THROUGHOUT Q <br /> 'g TEES 9. ALL OCCUPANCY SENSORS TO BE CONFIGURED TO <br /> TURN LUMINAIRES 100%OFF WHEN THE SPACE IS 5 L m <br /> Q <br /> ® W UNOCCUPIED. <br /> 10. SIDELIGHT WI NO MORE THAN 2 GENERAL LIGHTING l <br /> FIXTURES ARE NOT REQUIRED TO HAVE DAYLIGHT <br /> NO WORK IN SHADED AREA 1® RESPONSIVE CONTROLS PERC405.2.4. <br /> 5 11. LUMINAIRES IN PRIMARY B SECONDARY SIDELIGHT <br /> x DAYLIGHT ZONES MAY BE CONTROLLED TOGETHER <br /> IN SPACES WI NO MORE THAN 3 GENERAL LIGHTING <br /> FIXTURES IN DAYLIGHT ZONES. <br /> 12. LUMINAIRES INI SIDELIGHT ZONES FACING DIFFERENT <br /> CARDINAL ORg STAIR TOGETHER UP TO 2 LI GONS HT FIXTURES CONTROLLEDMAY BE EACH SPACE ° <br /> N0.1 SUITE 410 MAY BE CONTROLLED W/LIGHTING IN A DAYLIGHT - <br /> GENERAL CEILING NOTES: EZONE W/ <br /> XXCEPTIONFFERENT ORIENTATION_C405.2.4.1.6 <br /> w SUITE 403 - <br /> 1.SUSPENDED CEILING TO BE INSTALLED TO CISCA RECOMMENDATIONS FORAREAS SUBJECT TO SEVERE SEISMIC ACTIVITY 13. INTERIOR LIGHTING ALLOWANCES: - <br /> OFFICES=0.64 WIFT2 <br /> 2.CEILINGS SHALL BE HORIZONTAL TO ATOLERANCE OF 118"IN 10'-0"MEASURED EACH WAY.GRID TO REMAIN A CONTINUOUS PATTERN THROUGHOUT. <br /> 14. OPEN OFFICE AREAS SHALL HAVE GENERAL <br /> 3.HORIZONTAL SUPPORT SHALL BE PROVIDED BY FOUR WIRES MIN.NO.12 U.S.GAGE SPLAYED IN FOUR DIRECTIONS,90"APARTAND CONNECTED TO THE MAIN RUNNER LIGHTING CONTROLLED SEPARATELY IN CONTROL <br /> WITHIN 2"OF THE CROSS TEE AND TO THE STRUCTURE ABOVE ATAN ANGLE NOT EXCEEDING 45"FROM THE PLANE OF THE CEILING.THESE LATERAL SUPPORTS SHALL BE ZONES WITH FLOORAREAS NOT GREATER THAN 600 <br /> PLACED 12'-0'O.C.IN EACH DIRECTION,WITH THE FIRST POINT WITHIN 6'-0"FROM EACH WALL. SF WITHIN THE OFFICE SPACE.DEVICES SHALL <br /> - 4.VERTICAL SUPPORTS SHALL BE NO,12U.S.GAGE WIRE TO SUPPORTA MAXIMUM OF 16 SQUARE FEET OF CEILING AND SADDLE-TIED AROUND MAIN RUNNERS. AUTOMATICALLY TURN OFF GENERAL LIGHTING IN <br /> DISCONTINUOUS ENDS OF CROSS-RUNNERSAND MAIN RUNNERSTO BE VERTICALLY SUPPORTED WITHIN 8'OF CEILING DISCONTINUITIES,INCLUDING WALLS. ALL CONTROL ZONES WITH 20 P N PLAN FrERALL <br /> OFFICE <br /> OCCUPANTS HAVE LEFTTHE OPEN PLAN OFFICE <br /> 5.CEILING AREAS OVER 2,500 SF MUST HAVE SEISMIC SEPARATION JOINTS OR FULL HEIGHT PARTITIONS SPACE.DEVICES SHALL REDUCE LIGHTING IN EACH y.N <br /> ZONE BY NOT LESS THAN 80%WITHIN 20 MINUTES OF <br /> 6.CEILINGS WITHOUT RIGID BRACING MUST HAVE 2"OVERSIZED TRIM RINGS FOR SPRINKLERSAND OTHER PARTITIONS ALL OCCUPANTS LEAVING THAT CONTROL ZONE E <br /> (CONTROL FUNCTIONS THAT SWITCH CONTROL ZONE `m E <br /> 7.CHANGES IN CEILING PLANE MUST HAVE POSITIVE BRACING LIGHTS COMPLETELY OFF WHEN THE ZONE IS <br /> UNOCCUPIED MEET THIS REQUIREMENT).DAYLIGHT m Q_ <br /> ❑ 8.CABLE TRAYS AND ELECTRICAL CONDUITS MUST BE INDEPENDENTLY SUPPORTED AND BRACED RESPONSIVE CONTROLS ACTIVE OPEN PLAN OFFICE m <br /> SPACE GENERAL LIGHTING OR CONTROL ZONE <br /> 9.CONTRACTOR IS RESPONSIBLE FOR COSTAND COORDINATION OF SPECIAL INSPECTION IF REQUIRED BY LOCAL JURISTICTION GENERAL LIGHTING ONLY WHEN OCCUPANCY FOR W d <br /> THE SAME AREA IS DETECTED.SEC C405.2.1.3. c d <br /> 5 d <br /> Ux <br /> REFLECTED CEILING PLAN SUITE 400 & 402 i�Wa <br /> BUILDING PERMIT <br /> 11/26/24 <br /> REFLECTED CEILING PLAN <br /> A2 . 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.