Laserfiche WebLink
BOEING COMMERCIAL AIRPLANE GROUP <br /> BUILDING 40-056 <br /> MULTIPLE SMALL FENCE PROJECTS <br /> NEW FENCE/GATES <br /> BOEING EVERETT FACILITY �DLRGroup <br /> 3003 WEST CASINO ROAD 90% ISSUE FOR PERMIT <br /> EVERETT, WASHINGTON 98203 07.12.24 <br /> PROJECT DESIGN TEAM <br /> d OWNER: ARCHITECTURAL: <br /> ® PROJECT BOEING COMMERCIAL AIRPLANE GROUP DLR GROUP <br /> LOCATION I 3003 WEST CASINO ROAD 51 UNIVERSITY STREET, SUITE 600 <br /> EVERETT a 11 EVERETT, WASHINGTON 98203 SEATTLE, WASHINGTON 98101 <br /> IIIIIII PROJECT MANAGER: SCOTT WEST TEL: 206.461.6070 <br /> I TEL: 425.220.8762 CONTACT: ERWIN ANGULO <br /> 9 * Bc MAJOR ', s I <br /> WWW.DLRGROULP.COMRGROUP.COM <br /> BOEINGDEIND EADILRIES IIII[IIII <br /> g WET <br /> �� �� O IIII IIIIrr <br /> ELLEVUE <br /> LEGAL DESCRIPTION <br /> p.�, <br /> nLE i, o d > 40-56 LEGAL DESCRIPTION: <br /> so I <br /> RENTON = ® Il o 0 40-84 TAX ACCOUNT NO. 22284-4-001-0009 <br /> I 11 O ao-as <br /> Q THAT PORTION OF THE EAST HALF OF SECTION 22,TOWNSHIP 28 NORTH, RANGE 4 EAST,W.M. IN SNOHOMISH COUNTY, <br /> RENT ll fl w-� -_ ao-e3 WASHINGTON DESCRIBED AS FOLLOWS; <br /> f _ ❑ o-s1 BEGINNING AT THE SOUTHWEST CORNER OF SAID SECTION 22;THENCE N89'48'43"W ALONG THE SOUTH LINE THEREOF 201.19 <br /> BURN _ Ij Iry FEET TO THE CENTERLINE OF THE BEVERLY PARK-EDMONDS ROAD.THENCE N42'33'25"E ALONG SAID CENTERLINE 700.10 FEET: <br /> " THENCE S89°O5'S6"W 1023.57 FEET TO AN EXISTING NAVY MONUMENT;THENCE N00'54'04"289.49 FEET;THENCE S89'05'56"W <br /> 4o-at <br /> ° 5 10 y 0111 IIII ao-sa * 51.86 FEET;THENCE N00'54'04"W 278.33 FEET;THENCE CONTINUING NOO'54'04"W 1170.40 FEET;THENCE S89'05'56'W 419.58 <br /> \ '^ 1 0-31 40-32 40--- 40-34 <br /> FEET THENCE SOD' 54'04"E 50.00 FEET TO THE TRUE POINT OF BEGINNING: OF THIS DESCRIBED PARCEL;THENCE S0034'04"E <br /> MILES g �-N _„„_„,>„ww 40-35 40-36 <br /> TAcoMA � � 1114.27 FEET;THENCE S89'05'56"W 63.78 FEET;THENCE S00'54'04"E 106.62 FEET;TO A POINT WHICH BEARS N89'05'56"E <br /> -IIIj1 Illll ttli 578.00 FEET DISTANT FROM A BRASS CAP SET IN CONCRETE KNOWN AS S-2;THENCE S89'OS'56"W TO SAID MONUMENT S-2; <br /> Ij1 0 _ llllll 11,�1 �¢ 40-53 THENCE CONTINUING S89'05'56"W 395.20 FEET;THENCE N10'54'05"W 428.22 FEET;THENCE S89'05'56"W 340.57 FEET TO A <br /> E ER ii T �,� POINT ON A LINE THAT IS 750 FEET EASTERLY OF AND MEASURED PERPENDICULAR TO THE CENTERLINE OF RUNWAY 34L OF <br /> PAINE FIELD;THENCE N00'51'18"W PARALLEL WITH SAID CENTERLINE A DISTANCE OF 649.17 THENCE N89'05'56"E 250 FEET TO <br /> �� �� A POINT 1000.00 FEET EASTERLY OF AND MEASURED PERPENDICULAR TO SAID CENTERLINE THENCE N00'51'18'W PARALLEL WITH <br /> E❑-FT❑ p SAID CENTERLINE A DISTANCE OF 150.00 FEET TO A POINT WHICH BEARS S89'05'56'W FROM THE TRUE POINT OF BEGINNING. <br /> IIIIIII o PROJECT THENCE N89'05'56"E 685.82 FEET;THENCE S00'54'04"E 180.00 FEET THENCE N89'05'56"E 148.50 FEET;TO A POINT WHICH <br /> BUILDING BEARS S89'05'56"W FROM THE TRUE POINT OF BEGINNING;THENCE N89'05'56"E 335.40 FEET TO THE TRUE POINT OF <br /> n� PROJECT AREA BEGINNING. <br /> MISy RNER ® = ON 1ST FLOOR <br /> SITE PLAN N CODE SUMMARY <br /> FVINF FIELD d� °o — SCALE: N.T.S.ER bmt 2021 INTERNATIONAL BUILDING CODE W/ WA STATE AMENDMENTS, AS ADOPTED BY CITY OF EVERETT <br /> s 2021 INTERNATIONAL FIRE CODE W/ WA STATE AMENDMENTS AS ADOPTED BY CITY OF EVERETT <br /> SNOHOMI CO TY 3 2021 INTERNATIONAL MECHANICAL CODE W/ WA STATE AMENDMENTS, AS ADOPTED BY CITY OF EVERETT <br /> �F 2021 INTERNATIONAL FUEL CODE W/ WA STATE AMENDMENTS, AS ADOPTED BY CITY OF EVERETT <br /> UII g I]IIII[I 2021 UNIFORM PLUMBING CODE W/ WA STATE AMENDMENTS, AS ADOPTED BY CITY OF EVERETT <br /> p 2023 NATIONAL ELECTRIC CODE W/ WA STATE AMENDMENTS, AS ADOPTED BY CITY OF EVERETT <br /> 2018 AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) ANSI-ASTM A 117.1 <br /> PROJECT DESCRIPTION OCCUPANCY: <br /> EXISTING: FACTORY (F), BUSINESS (B) <br /> INSTALL SHOP FENCE AND SHOP DOOR ON THE FIRST FLOOR ALONG GRIDLINE P/5.5. PROPOSED; NO CHANGE <br /> VICINITY MAP LOCATION MAP AREA OF WORK: 529SF. CONSTRUCTION TYPE <br /> �I K I II-B, SPRINKLERED <br /> SCALE: N.T.S. N SCALE: N.T.S. N NO CHANGE TO OCCUPANT LOAD. <br /> OCCUPANT LOAD: <br /> PER TABLE 1004.1.1 <br /> NO CHANCE TO EXISTING <br /> EGRESS: <br /> SECTION 1021 PER TABLE 1021.1: TWO MEANS OF EGRESS REQUIRED <br /> SECTION 1016 PER TABLE 1016.1: EXIT ACCESS TRAVEL DISTANCE = 300 FEET (W/ SPRINKLERS) <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE <br /> ACCEPTABILITY R. ROGALSKI 06.16.02 COVER SHEET W9749677 O R 07.12.24 <br /> THIS DESIGN AND OR CHECKED <br /> ORIG NEW FENCE/GATES W9749677 DLR GROUP ECA 07.12.24 tote REGISTERED R. BERLIEN 06.16.02 SHEET <br /> ARC TEC SPECIFICATION IS APPROVED <br /> -BOE//VG® f � "I" TITLE NEW FENCE/GATES n 0 M <br /> APPROVED BY DEPT. DATE R. ROGALSKI 06.16.02 v <br /> CHECKED <br /> MICNAEL pAYIG VANGFA PLOEG R. BEREIEN G6.,6.G2 BUILDING 40-056 GTATE OP WAANINGTON APPROVED JOB N0. COMP N0. <br /> APPROVED ARCHITECTURAL MASTER EVERETT, WAI <br /> UWc NO. 40-056—GO <br />