My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7202 EVERGREEN WAY 2021 BASE FILE Plans 2025-09-10
>
Address Records
>
EVERGREEN WAY
>
7202
>
BASE FILE
>
Plans
>
7202 EVERGREEN WAY 2021 BASE FILE Plans 2025-09-10
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/10/2025 3:55:52 PM
Creation date
9/10/2025 3:53:21 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
7202
Tenant Name
BASE FILE
Permit
E2111-063
Year
2021
Notes
ELECTRICAL & COMMUNICATIONS & SITE LIGHTING-NORTON TERMINAL
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PANELBOARD 4MI 2000 A BUS SECTIONS: 1 PAD MOUNTED PANELBOARD 41L1 225 A BUS SECTIONS: 1 MOUNTED <br /> 480/ 277V 3 PHASE 4 WIRE 2000 A MCB LUGS: SINGLE NEMA PER ENVIRONMENT 480/ 277V 3 PHASE 4 WIRE MLO LUGS: SINGLE NEMA PER ENVIRONMENT <br /> LOCATION: AIC FEED: NUMBER OF POLES: 42 LOCATION: WITHIN 4M1 AIC FEED: NUMBER OF POLES: 30 <br /> CKT TYPE SERVES C.B. KVA CONNECTED PHASE LOAD KVA C.B. SERVES TYPE CKT CKT TYPE SERVES C.B. KVA CONNECTED PHASE LOAD KVA C.B. SERVES TYPE CKT <br /> 1 SF PANEL 4W1 1000/3 174.12 93.9 107.60 200/3 PANEL 41-1 SF 2 1 U I LP01-LP04 AREA LTG 60/3 20.14 8.8 4.24 20/2 LPO1-LP04 SECURITY LTG U 2 <br /> 3 ----- --- 93.9 --- ----- 4 3 ----- --- 8.8 --- ----- 4 <br /> 5 ----- ___ 93.9 _-- ----- 6 5 ----- --- 9.9 6.36 20/2 LP05-LP10 SECURITY LTG U 6 <br /> 7 SF PANEL 4P1 400/3 76.38 34.0 25.56 1200/3 PANEL 4S1 SF 8 7 U LP05-LP10 AREA LTG 60/3 29.15 12.9 --- AND LP20 8 <br /> --- 34.0 --- ----- 10 9 ----- --- 12.2 4.99 20/2 LP11-LP14 SECURITY LTG U 10 <br /> 9 -_-_ --- 12.2 --- AND LP21 12 <br /> 11 <br /> --- 34.0 --- ----- 12 11 ----- <br /> 13 1 SF JMPZ POLES WEST 40/2 1.08 1 0.5 14 13 U LP11-LP14 AREA LTG 60/3 21.20 7.1 /2 PREPARED SPACE 14 <br /> 15 1 1----- --- 1 0.5 16 15 ----- --- 7.1 --- ----- 16 <br /> 17 1 SF jMPZ POLES CENTER 50/2 1.44 0.7 18 17 ----- --- 7.1 /2 PREPARED SPACE 18 <br /> 19 1 1----- --- 0.7 20 19 PREPARED SPACE /3 0.0 --- ----- 20 <br /> 21 1 SF JMPZ POLES EAST 50/2 1.44 0.7 22 21 ----- --- 0.0 /2 PREPARED SPACE 22 <br /> 23 ----- 0.7 24 23 ----- --- 0.0 --- ----- 24 <br /> 25 0.0 26 25 PREPARED SPACE /3 0.0 30/3 SPD 26 <br /> 27 1 0.0 28 27 ----- --- 0.0 --- ----- 28 <br /> 29 0.0 30 29 ----- --- 0.0 --- ----- 30 <br /> 31 0.0 32 28.8 28.1 29.2 CALCULATED LOAD 107.6 KVA <br /> 33 0.0 34 MAXIMUM AMPS PER PHASE 131.6 AMPS <br /> 35 0.0 36 <br /> 37 0.0 30/3 SPD 38 NOTES: <br /> 39 0.0 -_- ----- 40 1. MOUNTED WITHIN SWITCHBOARD 4M1. <br /> 41 0.0 i I --- I----- 42 <br /> 129.1 129.1 129.3 CALCULATED LOAD 387.6 KVA <br /> MAXIMUM AMPS PER PHASE 466.9 AMPS <br /> NOTES: <br /> 1. SHOWN FOR LOAD CALCULATIONS ONLY, SEE ONE-LINE DIAGRAM FOR ALL OTHER INFORMATION. <br /> PANELBOARD 4W1 1000 A BUS SECTIONS: 1 PAD MOUNTED PANELBOARD MPZ 60 A BUS SECTIONS: 1 SURFACE MOUNTED <br /> 480/ 277V 3 PHASE 4 WIRE 1000 A MCB LUGS: SINGLE NEMA PER ENVIRONMENT 240/ 120V 1 PHASE 3 WIRE 30 A MCB LUGS: SINGLE NEMA PER ENVIRONMENT <br /> LOCATION: AC FEED: NUMBER OF POLES: 42 LOCATION: AIC FEED: NUMBER OF POLES: 12 <br /> CKT TYPE SERVES C.B. KVA CONNECTED PHASE LOAD KVA C.B. SERVES TYPE CKT CKT TYPE SERVES C.B. KVA CONNECTED PHASE LOAD KVA C.B. SERVES TYPE CKT <br /> 1 MO STORMWATER TREATMENT 250/3 116.39 38.8 100/3 SPARE 2 2 1 RE RECEPTACLE 20/1 0.18 0.2 20/1 SPARE 2 <br /> 3 ----- --- 38.8 --- ----- 4 3 SPARE 20/1 0.0 20/1 SPARE 4 <br /> --- 38.8 --- ---- 6 5 SPARE 20/1 0.0 20/1 SPARE 6 <br /> 7 MO STORMWATER LIFT STN 125/3 28.27 9.4 100/3 SPARE 8 2 7 SPARE 20/1 0.0 20/1 SPARE 8 <br /> ___ 9.4 ___ ----- 10 9 SPACE /1 0.0 /1 SPACE 10 <br /> 11 --- 9.4 --- ----- 12 11 SPACE /1 0.0 1 /1 SPACE 12 <br /> 13 SPACE /3 0.2 0.36 20/2 LIFT STN, TREATMENT MPZ SF 14 0.2 0.0 CALCULATED LOAD 0.2 KVA <br /> 15 --- 0.2 --- ----- 16 MAXIMUM AMPS PER PHASE 1.5 AMPS <br /> 17 _____ --- 0.0 /1 SPACE 18 <br /> 19 SPACE -13 0.0 /3 SPACE 20 NOTES: <br /> 21 0.0 --- 22 1. <br /> 23 ----- --- 0.0 --- 24 <br /> 25 SPACE /3 0.0 /3 SPACE 26 <br /> 27 --- <br /> 0.0 --- ----- 28 <br /> 29 ----- --- 0.0 --- ----- 30 <br /> 31 SPARE 20/3 0.0 20/1 SPARE 32 <br /> 33 ----- --- 0.0 20/1 SPARE 34 <br /> 35 ----- --- 0.0 20/1 SPARE 36 <br /> W 37 SPARE 20/3 0.0 30/3 SPD 38 <br /> 0.0 --- ----- 40 <br /> 41 ----- <br /> --- 0.0 --- ----- 42 <br /> E <br /> a 48.4 48.4 48.2 CALCULATED LOAD 174.1 KVA <br /> c MAXIMUM AMPS PER PHASE 209.7 AMPS <br /> a NOTES: <br /> c 1. PROVIDE GROUND FAULT PROTECTION WITH MAIN CIRCUIT BREAKER. W <br /> EA 2 FUTURE SHOREPOWER CIRCUIT, PROVIDE GROUND FAULT PROTECTION PER NEC 555.35. IF SHEET LESS THAN 22Y U) <br /> � REDUCE SCALE ACCORDINGLY <br /> c O <br /> PD. SI TERU: s� PORT OF EVERETT DWG. N0. E6.4Lu <br /> W g, D. SIATERUS NONE <br /> Er Porto ELCO N a DESIGNED BY. DATE: <br /> _0 1 ASSOCIATES,INC. N D. SIATERLIS o5�o7/2oz, NORTON TERMINAL DEVELOPMENT CIP No.1-8-900-OS 0 <br /> BmffnENGINEERS-CONSULTANTS E - DR""" CHEa® & M T C A 3 R D INTERIM ACTION PROJECT LL <br /> -15m A--wroe vwo C. SMITH S. BARTKOSKE <br /> �°""`w� . PANEL SCHEDULES No. MT-NT-2021-02.2 Z <br /> c n�l„�,s„ nlwsl3nasao (206)2a3-5022 www.elmn.mm /z�/zoz DI6 65UFD FOR BID .� V <br /> o P.O. BOX 538 PAOIERN(1.16001]0 /pT/Y0P p� pry�y�y �e1' APPRQ��• SHEET N0. OF 150 <br /> N 16300 CHRISTENSEN ROAD,STE 330 0 <br /> n EVERETT, WA 98206 SfATTLE WA 93188 <br /> / (425) 259-3164 N0. DATE BY REVSION N0. DATE BY REVISION 6A512I 129 <br /> z <br />
The URL can be used to link to this page
Your browser does not support the video tag.