My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9910 EVERGREEN WAY 2022 BUZZ INN STEAKHOUSE Plans 2025-09-11
>
Address Records
>
EVERGREEN WAY
>
9910
>
BUZZ INN STEAKHOUSE
>
Plans
>
9910 EVERGREEN WAY 2022 BUZZ INN STEAKHOUSE Plans 2025-09-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/11/2025 7:58:46 AM
Creation date
9/11/2025 7:57:39 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
9910
Tenant Name
BUZZ INN STEAKHOUSE
Permit
B2208-054
Year
2022
Notes
INSTALL (3) NEW ANTENNAS WITHIN EXISTING FENCED COMPOUND TO
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PROPOSED <br /> BLISS RIM WITH <br /> �TOR5 PROPOSED 4x1Yx1/4•TINNED • IX �� CONNECTION �T �VE <br /> TEST WELL COPPER MOUND BUSSBAR ■ MECHANICAL.CONNECTION <br /> • <br /> T, — .— . —. _ GROUND Bus BUR, ------ 0 Arc STRANDED k NSUUTED r <br /> . — � — � <br /> I - 12 AWG SOUR COPPER TINNED d..sh <br /> \ t90uPME]Q EN <br /> LAYOUT IS SCHEMATIC IN NATURE. O GROUND ROD <br /> I �_-- 1.( ♦ e. REFF7i TO SHEET A-3 FOR EQUIPMENT LAYOUT BUSS BAR INSULATOR <br /> BOND PROPOSED EQUIPMENT - <br /> PAD M PROPOSED <br /> GROUN <br /> SYSTEM (TYP.4) ! GROUNDING LEGEND 5701 SOUTH SANTA FE DRIVE <br /> '� LITTLETON, CO 80120 <br /> BOND H_FRAAE POST TO I { > •:• ' ' I DUSTING TOWER GROUND <br /> UNI-STRUT(TYP.) I I • RING (FEILD VERIFY) 1. GROUNDING IS SHOWN DI GRAMMATICA!"ONLY. <br /> BOND ICE BRIDGE <br /> • i ' s' SUPPORT FA75T5 TO 2 CONTRACTOR SHWl GROUND ALL EQUIPMENT AS A COMPLETE SYSTEIL GROUNDING SHALL BE N <br /> GROUND RING BOND(@) -----�` COMPLIANCE WITH NEC SECTION 250 AND DISH WkeW L.L.C. GROUNDING AND BONDING <br /> -'ALL POSTS) REAUEMS AND MANUFACTURERS SPECIFICATIONS. <br /> \\ �'' EXISTING MONOPOLE �] O <br /> /2 AWG BLARED GROUND /� I�s','• °'' p' I I \ 3 ALL GROUND CONDUCTORS SHALL BE COPPER; NO ALUMINUM C&MUCTDRS SHALL BE USED. <br /> RING 30'BELOW GRADE)— i II. ! /:t <br /> #2 TINNED SOLID <br /> LD IN1/2' I I 1000 HOLCOMB WOODS PKWY, <br /> MIN, ND O CONDUITGROUNDING KEY NOTES SUITE 210 <br /> " <br /> I ' ' I ROSWELL, GA 30076� NNOfi <br /> WIT �T <br /> 678-280-2325 <br /> CAD-WELD TERMINATION � � O /2 AWG SOLD COPPER, BURIED AT A DEPTH OF AT LEAST 30 INIHES BELOW <br /> POINT. EXPOSED END OF 1 H� I GRADE OR 6 INCHES BF1DW THE FROST LINE MID APPROXIMATELY'24 INCHES FROM THE EIRERlOR WALL <br /> THE LLCUID TIGHT CONDUIT I s OR FnoTNG <br /> MUST BE SEARED WITH :~ _• Tt]WFR GROUND RING- THE GROUND RING SYSTEM SHALL BE NSDILLED AROUND AN ANTENNA TOWER'S LEGS, '•`�`�' <br /> SILICONE;AUK ) a• ; ', \ I O AD/OR Gvl ANCHORS WHERE SEPARATE SYSTEMS HOE SEEN PROVIDED FOR THE TOWER AND THE <br /> BUILDING. AT LEAST TWO BONDS SMALL BE MADE BETWEEN THE TOWER RING GROUND SYSTEM AND THE <br /> BUILDING RING GROUND 3YSTEIA USING MINIMUM #2 AWG SOUR COPPER CONDUCTORS <br /> W —._ ._. — . ♦. W - --� O INTERIOR GROUND RNG_ t2 AYG STRANDED GREEN INSULATED COPPER CONDUCTOR EXTENDED AROUND THE � <br /> PERMETER OF THE EQUIPMENT AREA•ALL NON-TELMOYMUNCr1TiONS RELATED METALLIC OBJECTS FOUND <br /> BOND EQUIPMENT AS WTHN A SITE SHALL BE GROUNDED TO THE INTERIOR GROUND RING WITH #6 AWG STRANDED GREEN <br /> REQUIRED BY MANUFACTURER INSULATED CONDUCTOR. <br /> PROPOSED EQUIPMENT GROUND RING TD BOND TO NT6dOR GROUND RNc- //2 AWG SOLD TINNED COPPER WIRE PRIMARY BONDS SHALL BE <br /> D PROVIDED AT LEAST AT FOUR P00Nf5 ON THE INTERIOR GROUND RING LOCATED AT THE CORNERS OF THE <br /> EXISTING 7T)ARETR (AROUND RING (TOTAL 2) suftj NC-GROUND � <br /> TYPICAL EQUIPMENT GROUNDING PLAN NO SCALE O R SMALL LISTED COPPER WITH NSPEEC ICN�s1� DIAMETER swuL�iOTH D�EPTTH OF ND o7h1/w22 <br /> GROUND RING CONDUCTOR JBI NUMBER: 604-106-18 <br /> NOTES O �1 Rfft>TdCE c�ouwD && POINT OF GROUND REFERENCE FOR ALL COMMUNICATIONS EQUIPMENT IT IS A VIOLATION OF LAW FOR ANY PERSON, <br /> FRAMES.ALL BONDS ARE MADE WITH 2 AWG UNLESS NOTED OTHERYNSE STRANDED GTSEE7 RWLATED UNLESS THEY ARE ACTING UNOER THE DIRECTION <br /> PROPOSED LIPPE7t 7T>•/1ER ANTENNAS AND O!P SHOWN ARE ODIE6C AND NOT <br /> COPPER CONDUCTORS. BOND TO GROUND FLING WITH (2) /2 SOLD TINNED COPPER CONDUCTORS �A TO�PTHIRo DO ENGINEER, <br /> GROUND BUSS BAR REFERENCING TO A SPECFIC MMWACnNMt TM <br /> LAYOUT IS FOR REFERENCE PURPOSES ONLY MATCH PL431E MOUNID BAR: BOND TO THE INTERIOR GROUND RING WITH TWO/2 AWG STRANDED GREEN DRAWN BY: CHECKED BY: PROVED BY <br /> O INSULATED COPPER CONDUCTORS.WHEN A HATCH-PLATE AND A CELL REFERENCE GROUND EAR ARE BOTH <br /> PRIMIT,THE CROB MUST BE CONNECTED TO THE HATCH-PLATE MIND TO THE NTEIWR GROUND RING MSB MSB I MSB <br /> USING (2) TWO /2 AWG STRANDED GREEN INSULATED COPPER CONDUCTORS EACH. <br /> RFDS REV : --- <br /> OEL6H QT0R CABLE FDNTRt Parr 17Ra111D BARS LOCATED AT THE EN RIAMM TO THE CELL SITE BUILDING. BOND <br /> DRING WITH A/2 ANC SOLID TINNED COPPER CONDUCTORS WITH AN EXOTHERMIC WELD ANDINSPECTION SLEEVE. CONSTRUCTION <br /> PROPOSED #2 AWG <br /> STRANDED INSULATED c O COPPER MQ GROUND BAR! BOND TO BOTH CELL REFERENCE TAiWMD EAR M EKIMOR GROUND WING. DOCUMENTS <br /> / MNLMbW=THE BONDING POINT FOR TELECOM EQUIPMENT FRAMES SMALL BE THE GROUND BUS THAT SUBMITTALS <br /> PROPOSED 4'x6'xt/4'TINNED (D IS NOT ISOLATED FROM THE EQUIPMENTS METAL FRAMEWOW. <br /> COPPER SECTOR GROUND �_ REV DATE DESCRIPTION <br /> BUSS EAR (TYP OF(3)) O INTERIOR UNIT BOND& METAL FRAMES. CABINETS AND INDIVIDUAL METALLIC UNITS LOCATED WITH THE AREA A «✓%t Caen NO MM <br /> OF THE INTERIOR ROUND RING REQUIRE A+6 AWG STRADED GREEN INSULATED COPPER BOND TO THE o Uv/tt/a t�TORT mRalwettoL <br /> INTERIOR GROUND RING. <br /> \ 1 <br /> I O FF210E AID LATE GROUNDING! METAL FENCES WITHIN 7 FEET OF THE DfTESt10R GROUND RING OR OBJEC75 <br /> / I BONDED TO THE EXTERIOR GROUND RING SHALL BE BONDED TO THE WMNND RING WITH A j2 AWG SOLID <br /> f TINNED COPPER CONDUCTOR AT AN INTERVAL NOT EXCEEDING 25 FEET. BONDS SHALL BE MADE AT EACH <br /> I I GALE POST AND ACROSS GATE OPENINGS <br /> I <br /> BAR /2 1 <br /> PROPOSED GROUND __` I` ` ' TO THE O EXTERIOR UNIT BADS METALLIC OBJECTS, EXTERNAL TO OR MOUNTED TO THE BUILDING, SHALL EE BONDED A&E PROJECT NUMBER <br /> DTTEIRNOR TIROUND RIB. USING TINNED SOLID COPPER WIRE <br /> INSULATORS (TYP) 22t:t:DO$N-0041 <br /> �� \ <br /> OICE BRIDGE • EACH ICE BRDCE LEG SMALL BE BONDED TO THE GROUND RING WITH#2 AWG BARE <br /> \ TINNED COPPER CONDUCTOR. PROVIDE DOITHORMIC WELDS AT BOTH THE ICE BIWGE LEG AND BURIED <br /> \ GROUND FONG. DISH T INFOeless ATIO <br /> � PROJECT INFORMATION <br /> OODURING ALL DC POWER SYSTEM CHANCES INCLUDING DC SYSTEM CHANGE OUTS. RECTIFIER REPLACEMENTS SESEA002198 <br /> OR AODTKW BREAI(M DISTROJI10N CHANGES, BATTERY ADDITIONS• EMTTERY REPLACEMENTS AND <br /> WTALLATIONS OR CHANCES TO DC CONVEIMCONTRACTORS VERIFY ALL DC POWERSYSTEMS SYSTEMS ME IT EQUPPEDDwmH�MAS �DCSYS T SERVICE 9910 EVERGREEN WAY <br /> T URN GROUND <br /> CONDUCTOR FROM THE DC POWER SYSTEM COMMON RETURN Bus DUMMY CONNECTED TD THE CELL SITE EVERETT, WA 98204 <br /> PEED h REFERENCE GROUND BAR <br /> AM STRANDED <br /> COPPER GREEN PO TOWER TOP COLLECTOR BUSS EAR IS TO BE MECHANICALLY BONDED TO PROPOSED ANTENNA MOUNT COLLAR <br /> I!lSUIASFD �) SHEET TITTLE <br /> REM TO DISH WIt.M... LLC. GROUNDING NOTES. GROUNDING PLANS <br /> AND NOTES <br /> SHEET NUMBER <br /> G-1 <br /> TYPICAL ANTENNA GROUNDING PLAN NO SCALE 2 GROUNDING KEY NOTES WO SCALE 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.