My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2600 FEDERAL AVE 2022 PORT OF EVERETT Plans 2025-09-11
>
Address Records
>
FEDERAL AVE
>
2600
>
PORT OF EVERETT
>
Plans
>
2600 FEDERAL AVE 2022 PORT OF EVERETT Plans 2025-09-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/11/2025 8:35:50 AM
Creation date
9/11/2025 8:34:55 AM
Metadata
Fields
Template:
Address Document
Street Name
FEDERAL AVE
Street Number
2600
Tenant Name
PORT OF EVERETT
Permit
B2201-014
Year
2022
Notes
MODULAR RESTROOM BUILDING WITH ACCESS RAMPS
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
V,_ <br /> oT u� <br /> 4s-0• Rom V/V/EDLJ <br /> (7)16ki6'PADS&STEEL PIERS @W=4Z4r r-10• <br /> MOOULM BUIl01NG �'-- _ � _ <br /> mOOU 5 BUM - .. <br /> STEEL PER PER PUN& <br /> oTEs I LONGITUDINAL ANCHOR,3/Fl,EA END UPLIFT ANCHOR,4/Fl,FA SIDE <br /> NON-STRGCTURAL SORi1NG IOPIIOML) 6 C <br /> 16a16ABs PAD OR 1 24 P.T.PUNKS b <br /> ;• PER PLAN&NOTES.ON ASPHALT OVER <br /> j COMPACTED GRAVEL PAD <br /> PA <br /> PIER PAD SUPPORT <br /> sm=I/r"r-B m =- - - -` —�`- - - - — — — — — — — - - � <br /> 1• (6)SOIL ANCHORS,EA SIDE,,2JF1 <br /> MOOOLARBUILDING <br /> aASSG BMM <br /> I AO FOUNDATON PLAN <br /> sol i ArvaOR STRAP A s ALE:I♦ 1-0 <br /> MM-32 w/BURLE Tn <br /> r �5 SECONDSOILANa0R5TR 3 • <br /> REOUIREDTO GO TO NEXT RAR <br /> WHa PAIMARTANMOR MAP • <br /> EzcEEDs as• STRUCTURAL NOTES: m <br /> 50KANa0R PER PUN <br /> &NmFs L GENERAL BUILDING DESIGN: <br /> 1.1.VERIFY BUILDING DIMENSIONS PRIOR TO INSTALLATION OF FOUNDATION <br /> 11 L2.BUILDING RISK CATEGORY II O <br /> L3.A GEOTECHNICAL REPORT WAS NOT SUPPLIED BY THE OWNER FOR THE DESIGN OF <br /> THESE FOUNDATIONS.THE OWNER IS RESPONSIBLE FOR PROVIDING A SUITABLE <br /> 2 LATERAL STAB LE SUBGRADE FOR THE HE BUILDING FOUNDATION. od <br /> L DESIGN INFORMATION-P 2.1.BUILDING CODE IBC 2018,ASCE 7-16,WBC <br /> 2.2.ROOF UVE LOAD 25 PSF,SNOW <br /> MODULARWILDING 2.3.FLOOR LIVE LOAD 50 PSF OR 2,ODO#CONC. 0 <br /> cH is 8E 2.4.WIND CRITERION 1D0 MPH,EXP c,Kzt=1.0 <br /> 25.SEISMIC CRITERION SDS=0.834,1-1.0,SEISMIC CATEGORY,D <br /> 2.6.ASSUMED SOIL BEARING 1,500 PSF,SITE CLASS D(SOIL AT BOTTOM OF <br /> GRANULAR BASE) <br /> 3. CONCRETE: <br /> 3.L DESIGN COMPSTRENGTH 2,5DO PSI <br /> MMA-T1 12,REINFORCING YIELD 60 KSI <br /> wuANaox sTRav 8 <br /> - AND BEAM CONxECfOR MMi34 3. MASONRY: <br /> �A 3.1.8K16A9 UNffS ASTM C-90,GRADE N UJ m <br /> 32.SET UNITS W/CORES VERTICAL,PER PLAN. a a 8 N <br /> 3.3.STACXS OF 3 OR LESS SINGLE CAN BE DRY-STACKED. <br /> 501LARa0R PER 3.4.STACKS OF 4-6 UNITS TO BE DOUBLED DRY-STACKED W/EACH COURSE ROTATED 90 V) T <br /> PLAN&NOTES 'FROM COURSE BELOW. � ? `c � >r <br /> 3.5.STACKS OF OVER 6 UNITS TO BE GROUTED FULL WITH(1)#41N EACH OFTHE(4) <br /> CELLS. LA G Gd <br /> 4. WOOD: DO <br /> 4.1.GENERAL MEMBERS TO BE HF-CONST GRADE OR BETTER. ' <br /> LONGITUDINAL ANCHOR 41.BEAMS&POSTS TO BE HF#2 OR BETTER. W u` <br /> 3 ydP 1R-=I•_p 4.3.MEMBERS EXPOSED TO EARTH,CONCRETE OR MASONRY SHALL BE PRESSURE Z DO <br /> TREATED AND FASTENERS STAINLESS STEEL OR GALVANIZED. Q i S <br /> 4.4.ALL FASTENERS IN TREATED WOOD SHALL BE GALVANIZED BOX NAILS OR STAINLESS Lu c <br /> STEELCOMMON. 0 <br /> MODUTANBUIWING S. <br /> SPECIALTY ITEMS:("MINUTE MAN PRODUCTS,INC."(800)438-7277 a 3 b <br /> a is BEAM WWW.MINUTEMANPRODUCrS.COM) gG <br /> S.L METAL PIERS: <br /> so&ANaOR STRAP S.LL TO BE CAPABLE OF SUPPORTING 6,000# <br /> MM-32 W/BUCRLE 5.1.2. USE BOLTED CUP CONNECTOR AT HEAD OF PIER TO MODULE CARRIAGE RAIL <br /> S.L3. ATTACH BASE OF PIER TO CONCRETE WITH'SIMPSON'HD TITAN SCREWS OR <br /> STEEL PLEA PEP PUN& TO PLASTIC OF WOOD PADS WITH#12 PAN-HEADED WOOD-SCREWS AT Z <br /> NOM OPPOSITE CORNERS OF PADS. <br /> 16116AB5 PAD PER PLAN 5.2.SOIL ANCHORS(BASED ON A MAXIMUM HEIGHT OF FINISHED FLOOR=48"ABOVE Q <br /> i� &NOTE&ONCOMMCTEO FOUNDATION SUBGRADE) <br /> GRAVEL PAD 5.2.1. UPLIFTANCHORS-AUGER ANCHORS PRE-DRILLED THROUGH PAVEMENTAND z 2 <br /> T <br /> BASE INTO NATIVE SOILS MMA-92 OR GW2.SOR ANaOFFER S.2.1. X-DRIVE ANCHORS INTO COMPACTED GRAVEL OR ASPHALT SUBGRADEPUN&NOTES MMA-35.5.21. STRAPS ANCHOR HEAD TO RIM JOIST: L u Z0512.1. MMA-32FORSTRAPS WRAPPED AROUND THE RIM BEAM W/BUCKLE 51.21. MMA-71 FORSTRAPS BOLTED TO RIM JOISTS W ZFT ANCHOR 5.2.2. STRAPS SHALL SET AT 30TO4LT FROMHORIZONTAL IF STRAPS ARE SET AT >Imo'Y-0' MORE THAN 4S'TO OUTSIDE CARRIAGE RAIL INSTALLA SECOND STRAP TO THE LJJ x W m w <br /> NEXT ADJACENT RAIL LL w H <br /> 5.2.3. INSTALLALL SPECIALTY ITEMS PER THE MANUFACTURER'S Z Z 0O <br /> RECOMMENDATIONS. O ¢ o z p n <br /> 5.2.4. CONNECTANCHORTIES TO BUILDING ONLY AFTER BUILDING IS FULLY BLOCKED Z¢ wg o <br /> AND LEVELED. <br /> 6. VENTING:(IFSKIRTING INSTALLED) O o D_ c n <br /> 6.1.PROVIDE A C1A551 VAPOR RETARDER OVER ENTIRE CRAWLS SPACE J <br /> 61.PROVIDE VENTING TO RATIO OF 1 SQ.FT OF VENTILATION PER 1S00 SOLFT OF $ m <br /> CRAWLSPACE AREA. <br /> 6.3.PROVIDE MINIMUM OF ONE VENT NEAR EACH FOUNDATION CORNER FOR ~ N <br /> CROSS-VENTILATION. SD <br /> 7. ACCESS:(IF SKIRTING INSTALLED) <br /> 7.1.PROVIDE MINIMUM I8"x24"ACCESS TO THE UNDER FLOOR AREA rl f <br /> 7.2.PROVIDE 18"MIN.CLEARANCE FROM SUBGRADETO UNDERSIDE OF ANY 'i LSP u <br /> UNTREATED WOOD MEMBER. p <br /> 7.3.PROVIDE 12"MIN.CLEARANCE UNDER FROM SUBGRADE TO UNDERSIDE OF ALL <br /> BUILDING MEMBERS. REM90H DATE <br /> S. <br /> SITE CONDITIONS: 07/09/2017 <br /> 8.1.FOUNDATION SUBGRADE M 9-INCHES OF ASPHALT PAVING OVER 12-INCHES OF F 1 <br /> COMPACTED GRANULAR BASE OVER STABLE COMPACT SOIL <br /> SHEET: 1 OF 1 <br /> SCOTT mum <br />
The URL can be used to link to this page
Your browser does not support the video tag.