MATERIAL LIST <br /> ROOF: <br /> ROOFING.............EPDM 45 MIL MEMBRANE — NON—REINFORCED <br /> FULLY ADHERED — BLACK, OVER Y2" SECUROCK <br /> (AIR BARRIER COMPONENT) <br /> NOTE: TERMINATION BAR INSTALLED ON PERIMETER <br /> SHEATHING...........34" COX PLYWOOD (48/24) [2Y32" APA RATED] <br /> FRAMING.............2 x 8 DF#2 ®24"oc <br /> RIMS.................2 x 8 CONTINUOUS LVL 2.0E <br /> INSULATION..OAVITY:R-24 CELLULOSE BLOW—IN TO 7Y4' OVER CLASS <br /> 'A' MATERIAL (AIR BARRIER COMPONENT) <br /> ABOVE DECK:R-17 CONTINUOUS RIGID, LAYER ONE 136", LAYER <br /> TWO %", TOTAL THICKNESS 3" <br /> NOTE:WHERE TWO OR MORE LAYERS OF RIGID <br /> INSULATION ARE USED, EDGE JOINTS SHALL BE <br /> STAGGERED. <br /> TESTED IN ACCORDANCE WITH ASTM E84 OR UL <br /> 723 AT A MINIMUM THICKNESS OF 4X7. SEE <br /> ESR-3174. <br /> CEILING..............SUSPENDED T—BAR (PER IBC 808.1) <br /> VENTING.............NONE <br /> WALLS: <br /> SIDING...............76 SERIES LP SMARTSIDE PANEL T1-11 <br /> WITH GROOVES ®8"oc— USE 4'x9' PANELS <br /> FASCIA...............816" HIGH SIDE TAPERED ON SIDES TO <br /> 5Y2- LOW SIDE, NO GROOVE LP SMARTSIDE <br /> TRI M..................1 x 4 FINGER JOINTED CEDAR AT CORNERS, <br /> WINDOWS, AND DOORS <br /> NOTE:2'x2" GALV. FLASHING INSTALLED OVER SIDING <br /> AND UNDER CORNER TRIM <br /> FRAMING........EXT.2x6 DF f3 or 2x8 or BETTER STUDS ®16"oc <br /> INT:2 x 4 DF 0 Woo <br /> TOP PLATE..........2 x 6 CONTINUOUS (DF#2 OR LVL 2.OE) <br /> BOTTOM PLATE......2 x 6 OF <br /> -••.................................... pp INSULATION..........R-21 UNFACED FIBERGLASS BATTS <br /> .......................... <br /> INTERIOR FINISH......CLASS"C' 0.090 FRP TEXTURED FINISH OVER <br /> CAULK AT <br /> ROOF RIM/ <br /> TOP PLATE NOTE:INSTALL GYPSUM TO FULL HEIGHT ON INTERIOR OF <br /> EXTERIOR WALLS ABOVE WALL COVER (AIR BARRIER <br /> COMPONENT) <br /> SKIRTING.............SHIP LOOSE <br /> F MOISTURE............WRAP LOWER 12" OF BUILDING &CORNERS WITH <br /> _ PROTECTION MOIST—STOP. WRAP ENTIRE BUILDING WITH <br /> w w BUILDING WRAP <br /> x = <br /> 3 3. <br /> Lu 'w FLOOR: <br /> ' Lo COVERING............SHEET VINYL <br /> z z <br /> (L <br /> m = DECKING.........1sl:2)51" APA RATED STURD—I—FLOOR <br /> L) m (AIR BARRIER COMPONENT) <br /> I p I 2nd:Yi U—PLY X — ENTIRE BUILDING <br /> 01 <br /> .I FRAMING.............2 x 8 OF#2 FLOOR JOISTS AT 16'oc <br /> n RIMS........... ....2 x 8 CONTINUOUS LVL 2.0E <br /> CAULK WALL is ( ) <br /> CORNERS FROM INSULATION..........R-30 FIBERGLASS BATT USE 2 LAYERS R-15 <br /> TOP TO BOTTOM UNFACED FIBERFLASS BATT <br /> CAULK AT BOTTOM COVER......CLASS "A" <br /> FLOOR RIM/ BASE................4" RUBBER <br /> BOTTOM PLATE <br /> m FRAME: <br /> TYPE """ CONVENTIONAL(NO OUTRIGGERS, BUT WITH FULL <br /> CUSTOMER APPROVAL <br /> LENGTH FRONT&REAR C—CHANNEL CROSS MEMBERS) <br /> up 75}" ❑ APPROVED MAIN RAIL...........W10x12 <br /> N 9'-8" ❑ APPROVED EXCEPT AS NOTED AXLES................4—BRAKE 0—IDLER W/8:00 x 14.5 14—PLY TIRES <br /> WITH ROCKERS <br /> GR E ❑ REVISE AS NOTED AND RESUBMIT HITCH................DETACHABLE <br /> APPROVED By Date <br /> SECTION - A A> PRELIMINARY <br /> SCALE:v2"=V-0" NOT FOR CONSTRUCTION <br /> 12-7-21 PRELIM REVIEW-OG LDG Cc YRIGHT 2021,BLAZER INDUSTRIES,INC. MOBILE Approved forConsr Job No: 20060 <br /> THIS MATERIAL IS THE EXCLUSIVE PROPERTY ADARR for: <br /> OF BLAZER INDUSTRIES.INC.AND SHALL �■ File Copy: <br /> NOT BE REPRODUCED,USED,OR DISCLOSED10x46 port of Everett - Norton Expansion <br /> TO OTHERS EXCEPT AS AUTHORIZED BY THE �0 /Pd1DU,._TRlESNCOre—By: LDG <br /> DATE REVISION BY WRITTEN PERMISSION OF BLAZER INDUSTRIES. P.o.Boxaaew.iazertna.com WA Pacific Mobile Everett,WA fit! sas omey se. ■ Aumsvllle,OR 97325-0499 Issue Date: 12-7-21 <br />