Laserfiche WebLink
MATERIAL LIST <br /> ROOF: <br /> ROOFING.............EPDM 45 MIL MEMBRANE— FULLY ADHERED BLACK <br /> OVER Yz" SECUROCK (AIR BARRIER COMPONENT) <br /> NOTE TERMINATION BAR INSTALLED ON PERIMETER <br /> SHEATHING............'♦" COX PLYWOOD (48/24) [2%2 APA RATED] <br /> FRAMING.............2 x 8 DF#2 0 24"oc <br /> RIMS.................2 x 8 CONTINUOUS LVL 2.0E <br /> INSULATION...CAVITY:R-24 CELLULOSE BLOW—IN TO 7Y4" OVER CLASS <br /> 'A' MATERIAL(AIR BARRIER COMPONENT) <br /> ABOVE DECK:R-17 CONTINUOUS RIGID, LAYER ONE 1%", LAYER <br /> TWO 1X', TOTAL THICKNESS 3- <br /> NOTE:WHERE TWO OR MORE LAYERS OF RIGID <br /> INSULATION ARE USED, EDGE JOINTS SHALL BE <br /> STAGGERED. <br /> TESTED IN ACCORDANCE WITH ASTM E84 OR UL <br /> 723 AT A MINIMUM THICKNESS OF 4Yz7. SEE <br /> ESR-3174. <br /> CEILING..............SUSPENDED T—BAR (PER IBC 808.1) <br /> VENTING.............NONE <br /> WALLS: <br /> SIDING...............76 SERIES LP SMARTSIDE PANEL Tt-11 <br /> WITH GROOVES 0 8"oc— USE 4'00' PANELS <br /> FASCIA...............BX' HIGH SIDE TAPERED ON SIDES TO 5x" LOW <br /> SIDE, %" NO GROOVE LP SMARTSIDE PANEL) <br /> TRIM..................1 x 4 FINGER JOINTED CEDAR AT CORNERS, <br /> WINDOWS, AND DOORS <br /> NOTE:2%2" GALV. FLASHING INSTALLED OVER SIDING <br /> AND UNDER CORNER TRIM <br /> FRAMING.........D(T.2 x 6 OF #3 or BETTER STUDS 0 16"oc <br /> INT:2 x 4 OF 0 16"oc <br /> PLUMBING WALL TO BE 2 x 4 DF <br /> TOP PLATE..........2 x 6 CONTINUOUS(DF#2 OR LVL 2.OE) <br /> Y4 2 BOTTOM PLATE......2 x 6 OF <br /> is INSULATION..........R-21 UNFACED FIBERGLASS BATTS <br /> I a0 INTERIOR FINISH......%- VINYLWRAP SHEETROCK —FINISH & AIR BARRIER <br /> ........... <br /> ....................................... ................. <br /> NOTE:VINYLWRAP SHEETROCK TO FULL HEIGHT ON <br /> EXTERIOR WALLS (AIR BARRIER COMPONENT) <br /> CAULK AT SKIRTING.............SHIP LOOSE <br /> ROOF RIM/ <br /> TOP PLATE MIN. (2) 2 x 6 DF #2 MOISTURE............WRAP LOWER 12" OF BUILDING &CORNERS WITH <br /> HEADER OVER SIDEWALL PROTECTION MOIST—STOP. WRAP ENTIRE BUILDING WITH <br /> OPENINGS w/RIGID INSULATION BUILDING WRAP <br /> FILLER FLOOR: <br /> ~ <br /> CAULK = <br /> w AROUND ~- = w r COVERING............7Ei" VCT(TYP.) <br /> = WINDOWS o <br /> _ _j w DECKING.........]st24J2" APA RATED STURD—I—FLOOR <br /> 3 = (AIR BARRIER COMPONENT) <br /> 3 Z 2nd:Y" U—PLY X — ENTIRE BUILDING <br /> 0 oI U I d FRAMING.............2 x 8 DF #2 FLOOR JOISTS AT 16"oc <br /> m DOUBLE ^ o rn N RIMS.................2 x 8 CONTINUOUS (LVL 2.OE) <br /> AT HEADER - INSULATION..........R-30 FIBERGLASS BATT USE 2 LAYERS R-15 <br /> I <br /> AND SILL ^ UNFACED FIBERGLASS BATT <br /> CAULK <br /> CORNERSALL FROM o BOTTOM COVER......CLASS"A" <br /> TOP TO BOTTOM <br /> BASE................4' RUBBER <br /> CAULK AT <br /> FLOOR RIM/ FRAME. <br /> BOTTOM PLATE TYPE................CONVENTIONAL(NO OUTRIGGERS, BUT WITH FULL <br /> x LENGTH FRONT&REAR C—CHANNEL CROSS MEMBERS) <br /> m mvvvvvwvvvvvvmvvvvvvmvyyy MAIN RAIL...........W8x10 <br /> CUSTOMER APPROVAL AXLES...............2—BRAKE O—IDLER W/8:00 x 14.5 14—PLY TIRES <br /> 0 75J" ❑APPROVED WITH ROCKERS <br /> _ HITCH................DETACHABLE <br /> N B'-8" ❑ APPROVED EXCEPT AS NOTED <br /> G ADE ❑ REVISE AS NOTED AND RESUBMIT <br /> APPROVED By Date <br /> SECTION - A> A> PRELIMINARY <br /> SCALE:112"=T-0" NOT FOR. CONSTRUCTION <br /> COPYRIGHT 2021,BLAZER INDUSTRIES,INC. MOBILE BREAK ROOM for: AppfeVBd f.,QO0.1: k bNI: 20061 <br /> THIS MATERIAL IS THE EXCLUSIVE PROPERTY <br /> OF BLAZER INDUSTRIES.INC.AND SHALL ■■ File Copy: <br /> NOT BE OTHERS <br /> TA AUTHORIZED <br /> RIZEDBLOSED 10 x 30 port of Everett - Norton Expansion <br /> �� INDUSTRIES,INC. <br /> TO OTHERS EXCEPT AS AUTHORIZED BY THE OPO.BOX<6_ (/ <br /> www.blazednd.wm Drawn By: LDG <br /> DATE REVISION BY WRITTEN PERMISSION OF BLAZER INDUSTRIES. jj sasomeySt. 0 numsvIne,oRe'nzs-Does WA Pacific Mobile Everett,WA Iss�eDe;e: 11-29-21 <br />