My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2600 FEDERAL AVE 2022 PORT OF EVERETT Plans 2025-09-11 (3)
>
Address Records
>
FEDERAL AVE
>
2600
>
PORT OF EVERETT
>
Plans
>
2600 FEDERAL AVE 2022 PORT OF EVERETT Plans 2025-09-11 (3)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/11/2025 9:19:41 AM
Creation date
9/11/2025 9:18:07 AM
Metadata
Fields
Template:
Address Document
Street Name
FEDERAL AVE
Street Number
2600
Tenant Name
PORT OF EVERETT
Permit
B2201-016
Year
2022
Notes
MODULAR GUARDSHACK ON TOP OF CONCRETE FOUNDATION
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
W. <br /> of <br /> MODULAR BUILDING <br /> CHASSIS BEAM <br /> STEEL PIER PER PLAN& 30-0' <br /> NOTES <br /> 1'B' (5)1SX16 PADS&STL PIERS @ 81'=2T-0' 1 E' )mQE9 F/n/ma <br /> NON-STRUCTURAL SKIRTING(OPTIONAL) <br /> 16X16 ABS PAD OR 1ZK24 P.T.PLANKS 1-0 <br /> PER PLAN&NOTES,ON ASPHALT OVER <br /> COMPACTED GRAVEL PAD <br /> ` / PIER/PAD SUPPORT — d <br /> 6 LONGITUDINAL ANCHOR,3/Fl,EA END UPLIFT ANCHOR,4/FL EA SIDE <br /> a. <br /> - - - -�H <br /> MODULAR BUILDING <br /> CHASSIS BEAM _J <br /> SOIL ANCHOR STRAP i'-0 (4)SOIL ANCHORS,7JF1,EA SIDE <br /> MM-32 W/BUCKLE <br /> SECOND SOIL ANCHOR STRAP IS <br /> REQUIRED TO GO TO NEXT RAIL <br /> WHEN PRIMARY ANCHOR STRAP En <br /> EXCEEDS 45' <br /> --� -------- SOILANCHOR PER PLAN <br /> &NOTES <br /> • m <br /> STRUCTURAL NOTES: <br /> l� <br /> 1. GENERAL BUILDING DESIGN: Z3 <br /> L3.VERIFY BUILDING DIMENSIONS PRIOR TO INSTALLATION OF FOUNDATION -O <br /> 1.2.BUILDING RISK CATEGORY It O <br /> LATERAL ANCHOR 1.3.AGEOTECHNICAL REPORT WAS NOT SUPPLIED BY THE OWNER FOR THE DESIGN OF 2E <br /> / n THESE FOUNDATIONS.THE OWNER IS RESPONSIBLE FOR PROVIDING ASURABLE <br /> Scde:1/2' 1'-0' STABLE SUSGRADE FOR THE BUILDING FOUNDATION. C-6 <br /> 2. DESIGN INFORMATION&LOADING: Q1 <br /> 2.1.BUILDING CODE IBC 2018,ASCE 7-26,WBC <br /> MODULAR BUILDING 2.2.ROOF LIVE LOAD 25 PSF,SNOW ' O <br /> CHASSIS BEAM 2.4.FL FLOOND LIVE LOAD <br /> 500 M 0 PSF HREX�KCONC. <br /> 2.5.SEISMIC CRITERION SDS=O.B34,1-1.0,SEISMIC CATEGORY,D <br /> 2.6.ASSUMED SOIL BEARING LS00 PSF,SITE CLASS D(SOIL AT BOTTOM OF <br /> i GRANULAR BASE{ <br /> 3. CONCRETE: <br /> 3.1.DESIGN COMP.STRENGTH 2,500 PSI <br /> 3.2.REINFORCING YIELD 60 KSI 8 = <br /> 3. MASONRY: TS <br /> SOILANCHOR STRAP MMA-71 3.L BXl6X8 UNITS ASTM C-90,GRADE N W m <br /> AND BEAM CONNECTOR MMA-34 3.2.SET UNITS W/CORES VERTICAL,PER PLAN. t1 r R <br /> i 3.3 STACKS OF 30R LESS SINGLE CAN BE DRY-STACKED. - q <br /> 3.4.STACKS OF 4-6 UNITS TO BE DOUBLED DRY-STACKED W/EACH COURSE ROTATED 90 N G <br /> FROM COURSE BELOW. m b K <br /> 35.STACKS OF OVER 6 UNITS TO BE GROUTED FULL WITH(1)#4IN EACH OF THE(4) g <br /> - SOIL ANCHOR PER CELLS. K w E12 <br /> PLAN&NOTES 4. WOOD: en (D <br /> 4.1.ORAL MEMBERSTO BE HF-CONST GRADE OR BETTER. <br /> 4.2.BEAMS&POSTS TO BE HfX20R BETTER. > w tl <br /> 4.3.MEMBERS EXPOSED TO EARTH,CONCRETE OR MASONRY SHALL BE PRESSURE Z CO <br /> TREATED AND FASTENERS STAINLESS STEEL OR GALVANIZED. Q S� <br /> 4.4.ALL FASTENERS IN TREATED WOOD SHALL BE GALVANIZED BOX NAILS OR STAINLESS LL7 S.; a yQ <br /> STEELCOMMON. <br /> S. SPECIALTY ITEMS:("MINUTEMAN PRODUCTS,INC."800)438-7277 <br /> LONGITUDINAL ANCHOR 3 B <br /> j WWW.MINUTEMANPRODUCTS.COM) 9 G S;4 im:1'-0' S.L METAL PIERS: '¢ <br /> 5.I.L TO BE CAPABLE OF SUPPORTING 6,DODlt I <br /> SAZ USE BOLTED CLIP CONNECTOR AT HEAD OF PIER TO MODULE CARRIAGE RAIL. <br /> 5.L3. ATTACH BASE OF PIER TO CONCRETE WITH'SIMPSON'HD TITAN SCREWS OR Z <br /> TO PLASTIC OF WOOD PADS WITH#12 PAN-HEADED WOOD-SCREWS AT O <br /> MODULAR BUILDING OPPOSITE CORNERS OF PADS. 1= <br /> CHASSIS BEAM 5.2.SOIL ANCHORS(BASED ON A MAXIMUM HEIGHT OF FINISHED FLOOR-48"ABOVE <br /> FOUNDATION SUBGRADE) Z <br /> 5.2.L UPLIFT ANCHORS-AUGER ANCHORS PRE-DRILLED THROUGH PAVEMENT AND =) Z <br /> SOILANCHORSTRAP BASE INTO NATIVE SOILS MMA-92 OR GW2. n O ?� <br /> I� MM-32 W/BUCKLE 5.2.L X-DRIVE ANCHORS INTO COMPACTED GRAVELOR ASPHALTSUBGRADE m <br /> STEEL PIER PER PLAN& 5.2.2. STRAPS ANCHOR HEAD TO RIM JOIST: LSI <br /> ZO�+ Z W <br /> NOTES 52.2.1, MMA-32 FOR STRAPS WRAPPED AROUND THE RIM BEAM W/BUCKLE. H 0 Q y <br /> 5.2.2.2. MMA-71 FOR STRAPS BOLTED TO RIM JOISTS W Z <br /> s 5.2.7. STRAPS SHALL SET AT 30'TO 45'FROM HORIZONTAL IF STRAPS ARE SET AT > <br /> a m� <br /> 1SX26 ABS PAD PER PLAN MORE THAN 45'TO OUTSIDE CARRIAGE RAIL INSTALLA SECOND STRAP TO THE W X <br /> &NOTES,ON COMPACTED NEXT ADJACENT RAIL w 2 w <br /> GRAVELPAD 5.2.3. INSTALL ALL SPECIALTY ITEMS PER THE MANUFACTURER'S L.L. Z w 00 <br /> RECOMMENDATIONS. o 0 a 5 z g <br /> 52.4. CONNECTANCHOR TIES TO BUILDING ONLY AFTER BUILDING IS FULLY BLOCKED O QZ <br /> PER AND LEVELED � <br /> SOIL ANCHOR . <br /> PLAN NOTES <br /> 6. VENTING:(IF SKIRTING INSTALLED) O Z m� <br /> 6.L PROVIDE A CLASS I VAPOR RETARDER OVER ENTIRE CRAWLS SPACE <br /> 5.2.PROVIDE VENTING TO RATIO OF I SQFT OF VENTILATION PER 1500 SQ.FT OF 8 <br /> CRAWLSPACE AREA m <br /> 6.3.PROVIDE MINIMUM OF ONE VENT NEAR EACH FOUNDATION CORNER FOR O <br /> UPLIFT ANCHOR CROSS-VENTILATION, <br /> Y Sealc 7. ACCE55:(IFSKIRTINGINSTALLED) o W <br /> 7.L PROVIDE MINIMUM 18X24'ACCESS TO THE UNDER FLOOR AREA. ox o g <br /> 7.2.PROVIDE I8"MIN,CLEARANCE FROM SUBGRADETO UNDERSIDE OFANY ,y ' <br /> UNTREATED WOOD MEMBER. <br /> 0 <br /> 7.3.PROVIDE 12°MIN.CLEARANCE UNDER FROM SUBGRADE TO UNDERSIDE OF ALL <br /> BUILDING MEMBERS. FMV90N DATE: <br /> 8. SITE CONDITIONS: 12-21-2021 <br /> 8.1.FOUNDATION SUBGRADE IS 9-INCHES OF ASPHALT PAVING OVER 12-INCHES OF F 1 <br /> COMPARED GRANULAR BASE OVER STABLE COMPACT SOIL <br /> SHEET: 1 OF 1 <br /> SOOTf WILSON <br />
The URL can be used to link to this page
Your browser does not support the video tag.