Laserfiche WebLink
IF THIS PLAN IS NOT ON 22x34 PAPER,IT HAS BEEN SCALED ACCORDINGLY <br /> SCOPE OF WORK: LOT COVERAGE: CONTACTS: VICINITY MAP: Scale:l°=200' ---f OF SYMBOLS: LEGEND OF ABBREVIATED TERMS: <br /> RIFY <br /> PARCEL No.:00393900500401 0 — — = SEPTIC SEWER LINE FV = WATERFIELD MET <br /> 2 P,aP.nomer. swauei Enpineec = SIDE SEWER LINE WM = WATER METER d�_ � $ <br /> Section TOWri81Tlp Range Quarter 1. Interior remodel Ot eXiSting dwelling.Including cabinets,fixtures New Structures: 00.00 ft2 Felipe Saray T.B.D. =V6= = STORM WATER LINE EM = ELECTRIC METER Q > <br /> I u- 2 <br /> and appliances.Drywall repairs a5 needed. 2 ^�_° "tl°" ¢ — — = UNDERGROUND POWER GM = NATURAL GAS METER l)Og 3 <br /> �� 28 5 SE pp ryw p Existing Structures: + 913.00ft 14350 Addison ST.,Unit 207 a a — — = OVERHEAD POWER PP = POWER POLE <br /> 2. Rebuild rear deck"I ke for lilel F22 RY11`1 913.00 ft2 Los Angeles,California 91423 = WATER SUPPLY BPV = BURIED POWER VAULT S K11 E <br /> Total _> a $o <br /> STANDARDS: 3.Resurface front porch. ° ccm a 1 .r 1 — — = NATURAL GAS LINE AGT = ABOVE LAR ARRAY <br /> �1 e€ S <br /> ({OUSfi p.i= $-tit CTV Fell eSara 516 v��cnQ _ = PROPERTY LINE SP = SOLAR PANEUSOLAR ARRAY ° <br /> BuildingCode IRC 2018 Edition 4. '5T/Luc.-T-A/�1- R Lot Size: = 6,741.00 ft2(NET) P Y( )3aa-7621 cs.w = CENTERLINE OF STREET/ALLEY EVP = ELECTRIC VEHICLE PLUG 8ry <br /> P,°>arwai GEOT«hmui consuitrMo: �, = ROOF EAVE LINE ft, = SQUARE FOOT �■ <br /> EnergyCode WSEC 2018 Edition QL MdS ° 3.540�0 Nu CAD Drafting and Design n T.B.D. • : = WOOD FENCE EXIST = EXISTING r" <br /> Floor Loading 40 sf ILL/12 sf DL=52 sf Allowed: 35/o Actual: ttY g g 's 0 ° �„ - - = BUILDING SETBACK LINE FY BSBL= FRONT YARD BUILDING SETBACK LINE <br /> = TEMPORARY SILT FENCE SY BSBL= SIDE YARD BUILDING SETBACK LINE <br /> Deck(s)Loading 60 sf LL/10 sf DL=70 sf IMPERVIOUS AREA: 6300139th Avenue S.E. "., - <br /> ""�11'°"- � � = LAWN AREA(S) RV 858E= REAR YARD BUILDING SETBACK LINE <br /> 1: <br /> Roof Loadin 25 sf LL/17 sf DL=42 sf Snohomish,Washington 98290 - __ 9 1711g1 <br /> City of Everett 0 � = PAVED/CONCRETE HYD = FIRE HYDRANT <br /> Jurisdiction F.A.R.CALC: AVERAGE GRADE: New Impervious: 00.00 ft2 <° a CB = CATCH BASIN <br /> Zoning R 1 Exist/Re I Im erVI0U5:+ Douglas Almond(206)225-0068 ,yo eoee h DW = DRY WELL <br /> Lot Area: ft p p 2 378.00 ft2 a W O , YD = YARD DRAIN <br /> General C°nbeLlCf. W.P.WrcueerWl: e <br /> LEGAL DESCRIPTION: Maximum F.A.R.: ft2 2378.00 ft2 T B.D. T.B.D. " DS = DOWNSPOUT <br /> , <br /> BEVERLY PARK PLAT OF BLK 005 D-01 LOT 1 OF <br /> Total G.F.A.: ft2 Total: naam°. ,ua,as, P-TANK= PROPANE TANK <br /> CITY OF EVE SP 37-97 REC AFN9903175001 BEING Exemption Areas: ftZ Lot Size: _ 6,741.00 ft2(NET) <br /> A PTN OF LOT 4 EXST PLAT Chargeable Floor Area: ft2 p Know what's below. <br /> Chargeable+Lot Area= ft2 Allowed: 65%O Actual: 3 5.28% `° Call before you dig. <br /> WSEC 2018 ENERGY CODE COMPLIANCE: <br /> i The Washington State Energy Code requirements for alterations are located in Chapter 5 <br /> Alterations(remodels)do not need to obtain energy credits from Table R406.2 <br /> Additions must oe conditioned space construction.This includes nonconditioned space <br /> being altered to become <br /> Will the wall cavities be exposed? QVES ❑NO <br /> If yes:Exposed wall cavities must be insulated- <br /> 2x4 wall studs require R-15 insulation <br /> 2x6 wall studs require R-21 insulation <br /> will the roof/ceiling framing cavities or attic be exposed? ❑YES ®NO <br /> If yes:Exposed roof/ceiling assemblies must be insulated- <br /> Vaulted ceilings: while allowingeforllthe minimum fa <br /> eintged pacer <br /> Flat ceilings: Install R-49 insulation or what the attic space can <br /> I � I <br /> accommodate based on the roof pitch <br /> ., W ll the floor framing cavities be exposed? ❑YES ®NO <br /> LOT 3 BEVERLY PARK <br /> If yes:Exposed floor cavities must be insulated to R-30 0 <br /> o.�---o. PP Are the windows and/or doors being replaced? OYES ❑NO <br /> o-b, «—°°—°— -- ------ —--------—---- 135A0_N 89°34'0T_W __ a_�_ `__p_,�,--'--' —' Y <br /> —°�— _�_ _=, = & _ _ includes both window or door and frames) o <br /> •^ °t - If es:New windows and doors must have an area weighted average U-factor of s 0.30 ,; <br /> ° - - - - - -•' ------ ;- ; - - -�,- ; Will the heating or cooling system be replaced? ❑YES ❑NO <br /> — — — — — — — — — — -�;90"SY'�SBL=.-.-:.= — .— .= -. ... . v <br /> 2�,00' 20.00' r I If yes:New equipment must meet current requirements and _ <br /> I"""""-::� �--•-• ••---•--.-..-.'---' N ducts need to be tested N <br /> - - - - EXISTING CONC.WALKWAY <br /> , J O I Will the hot water system be altered? ❑YES ®NO O <br /> os t. <br /> T <br /> ......... - •_ - _ _ - O i If yes:New water heating equipment must meet current code requirements m <br /> Z I Are more than 50%of the light fixtures being changed? ■YES ❑NO S s <br /> -"Tu—I,—s: 3$ <br /> Q 1 V m 0 <br /> a FL LED or C'1 high efficacy a s must be:. f 7 of all lam ( )_ I es. 5%ss�-.• � Y P 9 of � <br /> O i Y w I R503.1.1 Building envelope:Building envelope assemblies that are part of the alteration shall comply with r <br /> ` -w Section R402.1.1 or R402.1.4,Sections R402.2.11,R402.3.t R4D2.3.2,R402.4.3 and R402.4.4. rn ro v, <br /> l'.'.".'.'.'.'.'. . .'.'.". . o w I. o � <br /> w I - - - I � 100 Exception:The following alterations need not comply with the requirements for new construction m W <br /> J F� Q <br /> ° a� DS TO LOW ROOF - <br /> Q K increased: <br /> - - . . - he building is not <br /> . . . . . . . . . . . he energy use of t <br /> V . . 10 <br /> w <br /> rowded t <br /> 9Y 9 <br /> ] Ln - - - Ufa p 1 } 00 1. Storm windows installed over existing fenestration. w n <br /> w O( . m • F-- ° 2. Existing ceiling,wall or floor cavities exposed during construction provided that these >_ <br /> O I LL •�EXISTING EXISTING J I O cavities are filled with insulation.2x4 framed walls shall be insulated to a minimum of In <br /> '.O •CONCRETE ' DWELLING F- I Z R-15 and 2x6 framed walls Shall be insulated to a minimum of R-21. <br /> I- N PARKING PAD 3. Construction where the existing roof,wall or floor cavity is not exposed. <br /> _ cc: V 11 _ - o --- �' O I M 4. Roof recover. <br /> = w N _ _ _ _ _ a O I S. Roofs without insulation in the cavity and where the sheathing or insulation is exposed <br /> = _ - - - - - - --- - - - - - -- O during reroofing shall be insulated either above or below the sheathing. I <br /> ~ p ~ t0� W. -. - " ' - '.'--.-.- � � � I� 6. Surface-applied window film installed on existing single pane fenestration assemblies m <br /> x _ <br /> -:::-:- -;-�•;•;•;-;-;•;-;•;•;•;•;•;-.-.-,-_-;-;-.-,. to reduce solar heat gain provided the code does not require the glazing fenestration S <br /> "J� --;, — — — '5.00'SY BSBL W i'Ds GM to be p ced. <br /> r J 1 re la o <br /> I 1 z <br /> .... wM - — — R503.1.1.1 Replacement fenestration:Where some or all of an existing fenestration unit is replaced with a <br /> w— w y� w— ,„— „,— w�::,; t._._;-1, — w —„. —w —w —w —w- _ - - _ _ _ - - _ - - - - _ - I - - - _ new fenestration product,including sash and glazing,the replacement fenestration unit shall meet the <br /> - - - - - - - - - -1- - applicable requirements for(bfactor and SHGC in Table R402.1.1. <br /> Q wi I 1 <br /> f.............i I R502.1.1.2 Heating and cooling systems:New heating,cooling and duct systems that are part of the <br /> addition shall comply with Sections R403.1,R403.2,R403.3 and R403.6. Pmn nne <br /> 0-4 20.00'ACCESS&UTILITY EASEMENT 1 Exce Ion:The followin need not com I with the testIn r uirements of Section R403.3.3. Existing Floor Plans <br /> �,/ THESE DOCUMENTS HAVE NOT BEEN 1 Additions of less than 50 square feet.p y 9 <br /> Fil 1 I APPROVED FOR THE ISSUANCE OF <br /> - _ J_•- - __ _- __1-o _1- _- _-•-_ __ __ __ __f-- __ __ _ PUBLIC WORK,MECHANICAL,FIRE 2. Duct systems that are documented st have been previously sealed as confirmed <br /> 0 - — —— — — —— —— —— —— — 135.00 S 89 34 07 E - SUPPRESSION,ELECTRICAL OR through field verification and diagnostic testing in accordance with procedures in WSU <br /> i PLUMBING PERMITS Existing systems constructed,n unconditionedd spaces. <br /> -- -- - - - linear feet lira insulated or seal with <br /> 3. Ducts with less than <br /> W - -�- - 4. 'sting dud ryzte Douglas Almond <br /> ��� R503.1.3 Service hot water systems:New service hot water systems that are part of the alteration shall 12 o9R023 <br /> FENCELINE RESOLUTION Additional Permits Are Required comply with Section R403.4. <br /> QUITCLAIM DEED ipN <br /> r This Project To Include:AF NO.:9901280631 lumbing Sprinkler R503.1.4 Ughtinq:New lighting systems that are part of the alteration shall comply with Section R404.1. <br /> SOUTH LINE OF LOT 4echanlcal I�Fire Alarm Exception:Ateratons that replace less than 50 percent of the luminaires in a space,provided thatLOT 5 BEVERLY PARKsuch alterations do not increase the installed interior lighting power. <br /> BEVERLY PARK PLAT Imo'���, <br /> **ALL ELECTRICAL,MECHANICAL, LW Electrical R503.2 Change in space conditioning:Any nonconditioned or low-energy space that is altered to become <br /> N PLUMBING,FRAMING NEEDS PERMITS** conditioned space shall be required to be brought into full compliance with this code. - <br /> INSTALLED OR ALTERED ELECTRICAL, CITY OF EVERETT p <br /> MECHANICAL,OR PLUMBING WITHOUT REVIEWED FOR PE'i^AI` PLAN Permit# 82401-0O1 <br /> Site Address: 8109 FLORIDA DR <br /> NORTH <br /> PERMITS OR INSPECTION OR APPROVAL 1 Owner: FEUPE SARAY O <br /> MUST BE UNCOVERED FOR INSPECTION** APPROVED Tenant: <br /> Office of Community,Planning It Economic Development APR 19 2024 Apo.Date: 1/2/2024 <br /> PLANNING DEPARTMENT Permit Type: RESIDENTIAL BUILDING <br /> CITY OF EVERETT Subtype: RESIDENTIALALTERATION(REMODEL, <br /> Name DATE: Perrnit Services REPAIR,ADDITION) <br /> REMODE <br /> Descriptlan: DECK <br /> 0R REM CH REBUILD EXTERIOR O�I <br /> DECKAND PORCH �,/ <br /> Reviewed By:�Date:Y////G I <br /> SCALE:1"=10.-0" I offine set Job site Set <br /> 1 SITE PLAN <br />