Laserfiche WebLink
IF THIS PLAN IS NOT ON 2204 PAPER,IT HAS BEEN SCALED ACCORDINGLY <br /> Max 24" Max 24" J <br /> _ frilins end Equal Distance Equal Distance Equal Distance yorn end oo <br /> Sill or Wall Plata <br /> Cou d also be a wall stud BEAM SPLICES MUST OCCUR U�$ a 3 <br /> 44 MIN.POST OVER POSTS w/1h'MIN.BEARING $ £ <br /> Exterior Wall Deck hoards 'i @ 72'o.c.MAX,TYP. <br /> ShaaMinp not shown in 'I 16'-- wS Q r w <br /> Deck Ledger this area Tor (MAX) CORROSION RESISTANT METAL GIRDER BEAM <br /> LTS LD no LTS Dack Tie LTS De I k Ti A z <br /> Deck Joist clarity COLUMN CAP.FOLLOW ALL Z <br /> N MANUFACTURERS INSTALLATION c <br /> INSTRUCTIONS <br /> Deck Beard Condition A Condition■ 2x8 <br /> �j MIN.18001b TENSION <br /> L JOISTS <br /> MIN.DECK DEVICE,TYP. <br /> B JOISTS&RIM q5, <br /> Si'O.D.GALV.BOLT W/ <br /> 4x4 KNEE BRACE <br /> NUTS&WASHERS,TVP. ry <br /> = SECTION A 0)3/8'DIAMETER THRU-BOLT <br /> rll it OR 1/2"LAG SCREW w/HOG <br /> ALTERNATE KNEE BRACE: WASHERS TOP&BOTTOM <br /> DESIGNER NOTES N <br /> 2x4 KNEE BRACE FACE <br /> Attachments made in acccordance with these details NAILED EA.SIDE OF POST P.T.POST PER PLAN <br /> NOTE: <br /> and the LTS installation instructions comply with IRC Use above details for guard connections or provide engineered AND BEAM w/(4)16d NAILS <br /> Section R507.9.2.1 requiring 4 lateral connections of design that shows Guards can resist a single concentrated load AT EACH FACE AND CONN. 24'MIN <br /> 750 pounds each from the deck joist to stud,plate or Condition C Condition D of 200lbs.applied in an direction at an pp y y point along the top and 71M)E"1r1iC-1- <br /> 01h TENSION OR 1/3 HEIGHT OF THE <br /> header of the house. have attachment devices and supporting stmctum to transfer this TyP. POST WHICHEVER IS GREATER <br /> load to appropriate structural elements of the building per IBC MIN.18001b TENSION <br /> Sea&1607.71.1. DEVICE,TYP. <br /> COMPLIANT TO CODES <br /> IRC,IBC,LABC,LARC,FBC,FRC SECTION B <br /> KNEE BRACES ARE REQUIRED ON ALL <br /> POSTS GREATER THAN 48'IN HEIGHT <br /> SUPPORTING TECHNICAL REPORTS <br /> IAMP0 Evaluation Report ER-447 5 <br /> (https://wwv iapmoes.orglbuilding-products-eveluation- <br /> report-program/evaluation-report-directory/) Condition E <br /> 1 FastenMaster@ LATERAL TIE DETAIL(S) N.T.S. 2 GUARDRAIL POST INSTALLATION N.T.S. 3 POST BRACE OPTION(S) N.T.S. <br /> Gapping and Overhang <br /> Decking and Fascia Recommended Fasteners <br /> If any condition occurs which is attributable to the use of non-recommended fasteners,such condition shall not be covered under the Trex You must gap Trex decking both end-to-end and <br /> DECKING Limited warranty. width-[o-width.Gapping is necessary for drainage and <br /> the slight thermal expansion and contraction of Trex (5 mm) <br /> decking boards.Gapping also allows for shrinkage of <br /> MANUFACTURED TYPICAL P.T.POST the wood joist system. <br /> w <br /> z POST CONNECTOR - , Nd sal en Faxon., » ALWAYS follow Trex-recommended v <br /> x re. x x gapping guidelines. <br /> O wn.x eone.ar.e r uen.r.ne z x a Maximum allowable perpendicular overhang for all o <br /> Trex decking <br /> a 12 Fro In,%svet t • x a All decks require air circulation ulation to keep them dry � <br /> Z (t TRIM FLUSH TO star" •m ro.wcacempesite(epexv coo. u <br /> I'I_ EDGE OF RIM JOIST 1ii1('""oo'OV°e ro..w.n..a roonon.pontauo�om» and looking good.To improve air flow,leave c <br /> GRADE t1� GRACE WCOR at.x BaDCU ser.w z <br /> aeili�ee.ivaonN nktFID,.�.r.e w.n�m s.m rp openings under the decking or increase gapping to Width-to-Width - <br /> • DECK PROTECTOR GRACE WCOR M z 3/8"(10 mm). The minimum required width-to-width gapping is - <br /> DECK PROTECTOR a F.n.nM,emr.Pa..a ulnmaw e"nPomm.ek ser.. x z x 3/16"(5 mm).This is allowed for both hot and cold <br /> t. eaon stmn.-na .rlv.Dcu mmPoalb serve, weather installations.For docks and heavily wooded <br /> g corbba a Hand-1 <br /> z x z areas,Trex recommends a 3/8"(10 mm)gap.No <br /> p r lk on- m i o « re. z x x 3/t6"(5 mm) gapping should ever exceed 1/2"(13 mm). <br /> RIM JOIST o z x x O Lmp <br /> s r SINGLE su,tw�oaoof:`,wE ,�ce.�baHa.�etaswrnle.. [o <br /> h'DIAMETER THROUGH Nw JOIST a a5.a.bcn-.d f..N.c e,�orreo n>I).1 ns enm x x x m N <br /> aPER TABL BOLTS IN BOTH DIRECTIONS orew .eta a D.,k Eaen.r sal Dnve e.ma.lb Deok sere. x z x z <br /> o w NOTE:NOT SCREWS q•GRAVEL m Fhurr s u w.a Yea ..re sa x z z -nd Abutting Gap <br /> 1/8"-3/16" o rn 3 <br /> nl S..-conabd z x % (3 mm-5 mm) (J N c <br /> Zw mxo212S erM TxasaosEM End-to-End/ O Q <br /> End-to-Width <br /> Abutting Gap m G <br /> NOTE: O ka.e.on sek-Nna.a x G1 o e g <br /> POSTS MUST BE CENTERED ON OR IN FOOTING Above 40°F'(45"C)' 1/8"(3 mm) 1/4"(6 mm) Il N N <br /> NOTES: Below 40°F'(,L5 C)' 3/16"(5 mm) 1/2"(13 mm) _O <br /> A.VISIT GRACECONSTRUCTION.COM FOR THE MOST CURRENT DETAILS,INSTALLATION VIDEO AND .na°wedan r..bnm.sysbm ror Fawb x x x 'r mpErature ati.......Air DC W <br /> PRODUCT INFORMATION SHEETS a u ra F PI $t f keser. E exv ee,be a sslnt.se x x <br /> orn ro .. n em or x <br /> i W stamom Desks.Faed.svxem-EPo v coxes•a H.woete sues— z x x When you use the recommended hidden fasteners, w o_ <br /> B.ALL EXPOSED(UNCOVERED)WCOR ALONG MOST OUTER EDGE SHOULD BE TRIMMED FLUSH WITH x� x x x (p <br /> JOIST TO PREVENT DAMAGE FROM UV ELL .tno"^Faeda son°" z the placement of the hidden fastener establishes the End-to-End/End-to-Width (/) <br /> FIGURE R507.3 rc sm eon smngn.Fsm Bo and s.w x x designated gap size. Gap Trex decking end-to-end,based upon the <br /> C.WCOR DOES NOT NEED TO BE TRIMMED IF COVERED WITH DECORATIVE TRIM,FASCIA OR OTHER F.W.F.sbn.r <br /> DECK POSTS TO DECK FOOTING CONNECTION Fealk—f T"pExe x x x temperature at installation.See chart at left. <br /> APPROPRIATE MATERIAL NOTES: For fastening tips,see page 13. <br /> •Do not use any hidden tashneb that are plug based with Trex Enhance FastenMeshF TapEasea3antl CorteF areregishred trademarks When installing fascia,gapping rules must apply. g <br /> 4 DECK FOOTING OPTIONS IRC2018 N.T.S. 5 VYCORS DECK/PATIO JOIST PROTECTION NT.S. prohkes wiMscalloped bottom, OPOMG,Inc. m <br /> F 2-3/41or3"screwscan be.,.with Trex 2.6 product. Oulk OrrM-aareglseredrndemarkend <br /> n Muro T-Screw M-TX03005EPlist.d.bovelsa,Provedbr2x6decking Compwi-Lo is,t d,markofsimpsonst w-Tie Company,.. g <br /> (canals,be used with standard l"(decking as listed above).Thus—is DeclrFase Cap-Tor'xd and HeadCoh°Cap.Torexdare registered Z <br /> Well singl DriDoin,((N0-THISISNOTACOLOR-14=11SCREW.)"FDVL41Speed tndemarksofRNbpm indusrrks mc. <br /> °Inmost,ses Plugged based fasteners canbeus ah2x6dacking C-Deck Exterfor Star Deck Composite Deck—Is aproductof <br /> Spacing Requirements product Alwaysrefer toscrew manufacturer for detalks. Screw Products I— 1/4"-1/2" <br /> x All decking productsareapproved for use with Trex Hideaway Hidden Phlillps ll Plus•Isareglshred bacem.—Phililps Fasteners LLC. <br /> Fasteners should be staggered in a"V"pattern and spaosd as follows: Fastener,lh us,11 decking Products can be nou[atl a aortling to Spllt3fop^screws arearegisteredtrademark of Titan Mehl Werks,lnc (6 m4-13 mm) <br /> A.Minimum end distance=3-3/4" our lme uctbns. <br /> Im wlrt Or BkxMng B.Minimum edge distance=l-3/4' n Simpsonstrong-Tie Deck Drive DCUCompositescrewlncollated Alen True <br /> C.On-Center spacing=Per Table 1 versions works with Ouik Drive gun. <br /> edgedok screw n•Not for use with sleeper systems.Rehr to Fast—s[er literature Framing Details <br /> III Plate for more Information.Also,In..are approved won Trex 2x6 SCREWS <br /> Wall sheathing dinkkng profiles. - <br /> Deckld ° -Faxlasyetemscrewe listed above can only be ned with composite profile Length No. <br /> m hseia proflb,antl cannot beusetl with standard thickness decking 1x6 2-1/2"or 2-3/4" #8,#10 Abutting Solid Objects - <br /> bond s used m fascia.Use stemless steer screws near When decking is abutting a wall,you must also gap it <br /> water applications. 2xfi 2-3/4"or 3" #8,#10 <br /> Rim Joists Blocking Trexrewmmendsthe un,ftwoecrews ,iolst 1/4"-1/tion.See <br /> chart <br /> depending on the temperature at <br /> Refer to Table 1 Rim Material installation.See Chart to the left. Douglas Almond <br /> Side View All recommendetl screws are designed to be metalled flueh fth <br /> decking surface.DO NOT countersink screws. <br /> zn92oz3 <br /> u Use recOmmentletl stainless steel screws in any areas near bodies <br /> Table 1:Fastening pattern for attachment of ledger to rim board using Led erLOK of saltwater. Improving. .o 0 0, <br /> < Ledger Board 9Pattr 9r 9 9 NOTE:Construction methods ere always!m !n please refer wwwtrex.rom/orlhemost up-to-date/nste//aflon requirements' 23-072-01 <br /> Refer to Table 1 for Ledger Material <br /> Live Load Ledger Rim Spacing between fasteners(In Inches)based on Joist Spans of. N w NOTE:Construction methods are always Improving.Please refer to wwtrex.ro en m for the most up-to-date Installation requirements] <br /> Material Material Material <br /> (I Upto B' Upto10' U to12' Up to 14'Up to t6' UDW18' amn Naw°.on: <br /> Doug.Fir 2x Lumber 24 18 14 12 10 9 8 0 4 PSF - <br /> or S.Pine EW Rim 25 19 15 12 10 9 8 O <br /> 0 0 <br /> Deckloist Hem Fir 2z Lumber 20 15 12 10 8 7 6 <br /> EW Rim 25 19 15 12 10 9 8 <br /> 2x Sill Plate Doug.Fir 2x Lumber 17 13 10 8 7 6 5 - <br /> Foundation Wall 60 PSF or 5.Pine EW Rim 18 13 10 9 7 6 6 <br /> LedgerLOK fastener. Hem Fir Lumber 14 11 B 7 6 5 4 <br /> Refer to spacing EW Rim 18 13 10 9 7 6 6 Q - <br /> requirements Nob;When innarledx lmttuced,the Led1101 bn be usedm reol—meW"s,Sws te Call.far In Tabb s022.2.i dhem lreme— 0 - <br /> kedderalalCadeaaC)or rats,I—or..1211 CITY OF El ERFT <br /> oNdeemuft REVIEWED FOR PE5 AIT <br /> NOTE: LedgerLOK =hPe` <br /> FOR COMPLETE DESIGN VALUES AND ENGINEERING DATA,AVAILABLE O� <br /> THROUGH TECHNICAL EVALUATION REPORT 1203-03,AND ESR#1078, <br /> AVAILABLE @ WWW.FASTENMASTER.COM Ledger Board Fastener <br /> 6 1 FastenMaster(D LedgerLOK8 SCREW DETAILS <br /> N.T.S. 7 DECKING FASTENING REQUIREMENTS N.r.s, 8 DECKING GAP REQUIREMENTS N.rs. 0, _ <br />