Notes
24 SQ FT DORMER 2ND FLOOR AND BASEMENT ADU
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WALL CONSTRUCTION <br /> TABLE R602.3(1) <br /> FASTENING SCHEDULE <br /> NUMBER AND TYPE SPACING AND LOCATION <br /> ITEM DESCRIPTION OF BUILDING ELEMENTS OF FASTENER".. <br /> Roof <br /> 4-8d box(2'/2"x 0.113'D or <br /> 1 Blocking between ceiling joists or rafters to top plate 3-8d common(21/2"x 0.13t`D;or Toe nail <br /> 3-10d box(3"x 0.128'D;or <br /> 3-3"x 0.131"nails <br /> 4-8d box 1(2'/2"x 0.113'D;or <br /> 3-8d common(2'/2"x 0.13 VD;or per joist,toe nail <br /> 2 Ceiling joists to top plate 3-10d box(3"x 0.128'D•or <br /> 3-3"x 0.131"nails <br /> 8'�;or 0.12 <br /> 3 Ceiling joist not attached to parallel rafter,laps over 4-1Od box(3"x 3-16d common(0.12 x 0.162'�;or Face nail <br /> partitions(see Section R802.5.2 and Table R802.5.2) 4-3"x 0.131"nails <br /> ' 4 Ceiling joist attached to parallel rafter(heel joint) Table R802.5.2 Face nail <br /> (see Section R802.5.2 and Table R802.5.2) <br /> 4-10d box(3"x 0.128'D;or <br /> 5 Collar tie to rafter,face nail or 1'/4"x 20 ga.ridge strap to 3-10d common(3"x 0.148");or Face nail each rafter <br /> rafter 4-3"x 0.131"nails <br /> 3-16d box nails(3'/2"x 0.135'�-or 2 toe nails on one side and 1 toe nail <br /> 3-10d common nails(3"x 0.148'D;or on opposite side of each rafter or <br /> 6 Rafter or roof truss to plate 4-10d box(3"x 0.128ID;or truss� <br /> 4-3"x 0.131"nails <br /> 4-16d(3'/z"x 0.135'D;or <br /> 3-10d common(3"x 0.148'D;or Toe nail <br /> 4-10d box(3"x 0.1281);or <br /> Roof rafters to ridge,valley or hip rafters or roof rafter 4-3"x 0.131"nails <br /> 7 to minimum 2"ridge beam 3-16d box 3'/2"x 0.135");or <br /> 2-16d common(31/2"x 0.162%or End nail <br /> 3-1Od box(3"x 0.128'D;or <br /> 3-3"x 0.131"nails <br /> Wall <br /> 16d common(31/Z"x 0.162'� 24"o.c.face nail <br /> 8 Stud to stud(not at braced wall panels) 10d box(3"x 0.128'D;or 16"o.c.face nail <br /> 3"x 0.131"nails <br /> 16d box(3'/Z"x 0.135');or 12"o.c.face nail <br /> 9 Stud to stud and abutting studs at intersecting wall corners 3"x 0.131"nails <br /> (at braced wall panels) 16d common(3'/2"x 0.1 16"o.c.face nail <br /> 16d common(3'/Z"x 0.162D 16"o.c.each edge face nail <br /> 10 Built-up header(2"to 2"header with spacer) 16d box(3'/Z"x 0.135'D 12"o.c.each edge face nail <br /> 5-8d box(2'/2"x 0,113'D;or <br /> 11 Continuous header to stud 4-8d common(21/Z"x 0.131');or Toe nail <br /> 4-1Od box(3"x 0.128') <br /> 16d common(31/z"x 0.162D 16"o.c.face nail <br /> 12 Top plate to top plate 10d box(3"x 0.128'D;or 12"o.c.face nail <br /> 3"x 0.131"nails <br /> 8-16d common(3'/2"x 0.1621);or Face nail on each side of end joint <br /> 12-16d box(31/2"x 0.135'D;or (minimum 24"lap splice length each <br /> 13 Double top plate splice 12-10d box(3"x 0.128");or <br /> side of end joint) <br /> 12-3"x 0.131"nails <br /> (continued) <br /> 174 2018 INTERNATIONAL RESIDENTIAL CODE® <br />
The URL can be used to link to this page
Your browser does not support the video tag.